{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T01:27:28Z","timestamp":1793928448160,"version":"4.8.0"},"reference-count":78,"publisher":"American Medical Association (AMA)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JAMA Cardiol"],"published-print":{"date-parts":[[2025,6,1]]},"abstract":"<jats:sec id=\"ab-hrv250001-1\"><jats:title>Importance<\/jats:title><jats:p>Hypertension is a primary modifiable risk factor for cardiovascular death and disability. Accurate blood pressure (BP) measurement is essential for the diagnosis and treatment of hypertension. Conventional BP measurement with cuff devices is recommended but difficult for patients to perform due to inconvenience, discomfort, and challenges with appropriate cuff sizing and measurement protocols. The emergence of cuffless BP devices provides an opportunity to address many of these problems, including inconvenience, patient comfort, positional requirements, and continuous measurement.<\/jats:p><\/jats:sec><jats:sec id=\"ab-hrv250001-2\"><jats:title>Observations<\/jats:title><jats:p>Cuffless BP measurement devices are appealing to patients and clinicians, but validation of these technologies is essential before they can be deployed for clinical use. Key issues that remain include accuracy with risk of undertreatment or overtreatment, equitable access for low- and middle-income countries and minoritized populations, data privacy concerns, and how the devices will be deployed in clinical practice.<\/jats:p><\/jats:sec><jats:sec id=\"ab-hrv250001-3\"><jats:title>Conclusions<\/jats:title><jats:p>Clinicians and patients should only use validated BP cuff devices until cuffless BP measurement devices are appropriately tested and validated.<\/jats:p><\/jats:sec>","DOI":"10.1001\/jamacardio.2025.0662","type":"journal-article","created":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T15:31:06Z","timestamp":1745422266000},"page":"624","source":"Crossref","is-referenced-by-count":37,"title":["Cuffless Blood Pressure Measurement Devices\u2014International Perspectives on Accuracy and Clinical Use"],"prefix":"10.1001","volume":"10","author":[{"given":"Eugene","family":"Yang","sequence":"first","affiliation":[{"name":"University of Washington School of Medicine, Seattle"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aletta E.","family":"Schutte","sequence":"additional","affiliation":[{"name":"School of Population Health, University of New South Wales, Sydney, New South Wales, Australia"},{"name":"The George Institute for Global Health, Sydney, New South Wales, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Stergiou","sequence":"additional","affiliation":[{"name":"Hypertension Center STRIDE-7, National and Kapodistrian University of Athens, School of Medicine, Third Department of Medicine, Sotiria Hospital, Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fernando Stuardo","family":"Wyss","sequence":"additional","affiliation":[{"name":"Guatemala Cardiovascular Services and Technology, Guatemala City, Guatemala"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yvonne","family":"Commodore-Mensah","sequence":"additional","affiliation":[{"name":"Johns Hopkins Bloomberg School of Nursing, Baltimore, Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Augustine","family":"Odili","sequence":"additional","affiliation":[{"name":"College of Health Sciences, University of Abuja, Abuja, Nigeria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ian","family":"Kronish","sequence":"additional","affiliation":[{"name":"Center for Behavioral Cardiovascular Health, Columbia University Irving Medical Center, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hae-Young","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Division of Cardiology, Seoul National University Hospital, Seoul, South Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daichi","family":"Shimbo","sequence":"additional","affiliation":[{"name":"Columbia Hypertension Lab, Columbia University Irving Medical Center, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10","reference":[{"issue":"25","key":"hrv250001r1","doi-asserted-by":"publisher","first-page":"2361","DOI":"10.1016\/j.jacc.2022.11.005","article-title":"The global burden of cardiovascular diseases and risk: a compass for future health.","volume":"80","author":"Vaduganathan","year":"2022","journal-title":"J Am Coll Cardiol"},{"issue":"6","key":"hrv250001r3","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1161\/CIRCULATIONAHA.115.018912","article-title":"Global disparities of hypertension prevalence and control: a systematic analysis of population-based studies from 90 countries.","volume":"134","author":"Mills","year":"2016","journal-title":"Circulation"},{"issue":"9","key":"hrv250001r5","doi-asserted-by":"publisher","first-page":"1971","DOI":"10.1161\/HYPERTENSIONAHA.122.19222","article-title":"Blood pressure control among US adults, 2009 to 2012 through 2017 to 2020.","volume":"79","author":"Muntner","year":"2022","journal-title":"Hypertension"},{"issue":"3","key":"hrv250001r6","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/j.jacc.2023.04.054","article-title":"Consumer wearable health and fitness technology in cardiovascular medicine: JACC state-of-the-art review.","volume":"82","author":"Petek","year":"2023","journal-title":"J Am Coll Cardiol"},{"key":"hrv250001r7","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1007\/s11628-020-00428-3","article-title":"Health care wearable devices: an analysis of key factors for continuous use intention.","volume":"14","author":"Lee","year":"2020","journal-title":"Serv Bus"},{"issue":"5","key":"hrv250001r9","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1097\/HJH.0000000000001987","article-title":"Nocturnal blood pressure measured by home devices: evidence and perspective for clinical application.","volume":"37","author":"Asayama","year":"2019","journal-title":"J Hypertens"},{"issue":"6","key":"hrv250001r10","doi-asserted-by":"publisher","first-page":"1593","DOI":"10.1161\/HYPERTENSIONAHA.120.14719","article-title":"Nonvalidated home blood pressure devices dominate the online marketplace in Australia: major implications for cardiovascular risk management.","volume":"75","author":"Picone","year":"2020","journal-title":"Hypertension"},{"issue":"4","key":"hrv250001r11","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1097\/MBP.0000000000000531","article-title":"Blood pressure from the optical Aktiia bracelet: a 1-month validation study using an extended ISO81060-2 protocol adapted for a cuffless wrist device.","volume":"26","author":"Vybornova","year":"2021","journal-title":"Blood Press Monit"},{"issue":"41","key":"hrv250001r12","doi-asserted-by":"publisher","first-page":"4222","DOI":"10.1093\/eurheartj\/ehac474","article-title":"The promise and pitfalls of novel cuffless blood pressure devices.","volume":"43","author":"Schutte","year":"2022","journal-title":"Eur Heart J"},{"issue":"8","key":"hrv250001r13","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCIMAGING.119.008857","article-title":"Smartphone-based blood pressure measurement using transdermal optical imaging technology.","volume":"12","author":"Luo","year":"2019","journal-title":"Circ Cardiovasc Imaging"},{"issue":"431","key":"hrv250001r14","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.aap8674","article-title":"Smartphone-based blood pressure monitoring via the oscillometric finger-pressing method.","volume":"10","author":"Chandrasekhar","year":"2018","journal-title":"Sci Transl Med"},{"key":"hrv250001r15","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2023.1138647","article-title":"Developing a real-time detection tool and an early warning score using a continuous wearable multiparameter monitor.","volume":"14","author":"Eisenkraft","year":"2023","journal-title":"Front Physiol"},{"issue":"9","key":"hrv250001r16","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1038\/s41551-018-0287-x","article-title":"Monitoring of the central blood pressure waveform via a conformal ultrasonic device.","volume":"2","author":"Wang","year":"2018","journal-title":"Nat Biomed Eng"},{"issue":"8","key":"hrv250001r17","doi-asserted-by":"publisher","first-page":"864","DOI":"10.1038\/s41565-022-01145-w","article-title":"Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos.","volume":"17","author":"Kireev","year":"2022","journal-title":"Nat Nanotechnol"},{"issue":"1","key":"hrv250001r18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1145\/3132024","article-title":"Glabella: continuously sensing blood pressure behavior using an unobtrusive wearable device.","volume":"3","author":"Holz","year":"2017","journal-title":"Proc ACM Interact"},{"issue":"1","key":"hrv250001r19","doi-asserted-by":"publisher","first-page":"8605","DOI":"10.1038\/s41598-023-35492-y","article-title":"Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations.","volume":"13","author":"Joung","year":"2023","journal-title":"Sci Rep"},{"issue":"1","key":"hrv250001r20","doi-asserted-by":"publisher","DOI":"10.2196\/12419","article-title":"In-home cardiovascular monitoring system for heart failure: comparative study.","volume":"7","author":"Conn","year":"2019","journal-title":"JMIR Mhealth Uhealth"},{"issue":"8","key":"hrv250001r21","doi-asserted-by":"publisher","first-page":"1449","DOI":"10.1097\/HJH.0000000000003224","article-title":"Cuffless blood pressure measuring devices: review and statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability.","volume":"40","author":"Stergiou","year":"2022","journal-title":"J Hypertens"},{"issue":"1","key":"hrv250001r22","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1109\/TBME.2021.3087105","article-title":"Photoplethysmography fast upstroke time intervals can be useful features for cuff-less measurement of blood pressure changes in humans.","volume":"69","author":"Natarajan","year":"2022","journal-title":"IEEE Trans Biomed Eng"},{"key":"hrv250001r23","doi-asserted-by":"publisher","DOI":"10.3389\/fmedt.2022.899143","article-title":"Guidance for the interpretation of continual cuffless blood pressure data for the diagnosis and management of hypertension.","volume":"4","author":"Sola","year":"2022","journal-title":"Front Med Technol"},{"issue":"11","key":"hrv250001r24","doi-asserted-by":"publisher","first-page":"1171","DOI":"10.1093\/ajh\/hpab095","article-title":"Twenty four\u2013hour ambulatory blood pressure measurement using a novel noninvasive, cuffless, wireless device.","volume":"34","author":"Nachman","year":"2021","journal-title":"Am J Hypertens"},{"issue":"2","key":"hrv250001r25","doi-asserted-by":"publisher","first-page":"93","DOI":"10.4070\/kcj.2023.0303","article-title":"Feasibility and effectiveness of a ring-type blood pressure measurement device compared with 24-hour ambulatory blood pressure monitoring device.","volume":"54","author":"Lee","year":"2024","journal-title":"Korean Circ J"},{"key":"hrv250001r26","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2022.958212","article-title":"Smartwatch-based blood pressure measurement demonstrates insufficient accuracy.","volume":"9","author":"Falter","year":"2022","journal-title":"Front Cardiovasc Med"},{"issue":"6","key":"hrv250001r27","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1097\/HJH.0000000000003428","article-title":"Evaluation of the ability of a commercially available cuffless wearable device to track blood pressure changes.","volume":"41","author":"Tan","year":"2023","journal-title":"J Hypertens"},{"issue":"9","key":"hrv250001r28","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1038\/s41371-024-00932-3","article-title":"Wearable cuffless blood pressure tracking: when will they be good enough?","volume":"38","author":"Schutte","year":"2024","journal-title":"J Hum Hypertens"},{"issue":"1","key":"hrv250001r29","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.cvdhj.2023.01.001","article-title":"Validating cuffless continuous blood pressure monitoring devices.","volume":"4","author":"Hu","year":"2023","journal-title":"Cardiovasc Digit Health J"},{"issue":"3","key":"hrv250001r30","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1097\/HJH.0000000000001634","article-title":"A universal standard for the validation of blood pressure measuring devices: Association for the Advancement of Medical Instrumentation\/European Society of Hypertension\/International Organization for Standardization (AAMI\/ESH\/ISO) Collaboration Statement.","volume":"36","author":"Stergiou","year":"2018","journal-title":"J Hypertens"},{"issue":"3","key":"hrv250001r31","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1161\/HYPERTENSIONAHA.122.20410","article-title":"The Microsoft Research Aurora Project: important findings on cuffless blood pressure measurement.","volume":"80","author":"Mukkamala","year":"2023","journal-title":"Hypertension"},{"issue":"12","key":"hrv250001r32","doi-asserted-by":"publisher","first-page":"2074","DOI":"10.1097\/HJH.0000000000003483","article-title":"European Society of Hypertension recommendations for the validation of cuffless blood pressure measuring devices: European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability.","volume":"41","author":"Stergiou","year":"2023","journal-title":"J Hypertens"},{"issue":"5","key":"hrv250001r33","doi-asserted-by":"publisher","first-page":"1161","DOI":"10.1161\/HYPERTENSIONAHA.121.17747","article-title":"Evaluation of the accuracy of cuffless blood pressure measurement devices: challenges and proposals.","volume":"78","author":"Mukkamala","year":"2021","journal-title":"Hypertension"},{"key":"hrv250001r34","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1146\/annurev-bioeng-110220-014644","article-title":"Cuffless blood pressure measurement.","volume":"24","author":"Mukkamala","year":"2022","journal-title":"Annu Rev Biomed Eng"},{"issue":"2014","key":"hrv250001r36","first-page":"1","article-title":"IEEE standard for wearable cuffless blood pressure measuring devices.","volume":"1708","year":"2014","journal-title":"IEEE Std"},{"issue":"2019","key":"hrv250001r37","first-page":"1","article-title":"IEEE standard for wearable, cuffless blood pressure measuring devices.","volume":"1708a","year":"2019","journal-title":"IEEE Std"},{"issue":"4","key":"hrv250001r38","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1038\/s41440-023-01215-z","article-title":"Feasibility and measurement stability of smartwatch-based cuffless blood pressure monitoring: a real-world prospective observational study.","volume":"46","author":"Han","year":"2023","journal-title":"Hypertens Res"},{"issue":"1","key":"hrv250001r39","doi-asserted-by":"publisher","DOI":"10.1080\/08037051.2023.2255704","article-title":"Accuracy of cuff-less, continuous, and non-invasive blood pressure measurement in 24-h ABPM in children aged 5-17.","volume":"32","author":"Bothe","year":"2023","journal-title":"Blood Press"},{"issue":"4","key":"hrv250001r40","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1097\/HJH.0000000000003667","article-title":"Ability of a 24-h ambulatory cuffless blood pressure monitoring device to track blood pressure changes in clinical practice.","volume":"42","author":"Derendinger","year":"2024","journal-title":"J Hypertens"},{"issue":"1","key":"hrv250001r41","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1186\/s12872-021-02351-5","article-title":"The quality of patients\u2019 self-blood pressure measurements: a cross-sectional study.","volume":"21","author":"Nessler","year":"2021","journal-title":"BMC Cardiovasc Disord"},{"issue":"10","key":"hrv250001r42","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.1001\/jamainternmed.2023.3264","article-title":"Effects of cuff size on the accuracy of blood pressure readings: the Cuff(SZ) Randomized Crossover Trial.","volume":"183","author":"Ishigami","year":"2023","journal-title":"JAMA Intern Med"},{"issue":"11","key":"hrv250001r43","doi-asserted-by":"publisher","first-page":"2317","DOI":"10.1097\/HJH.0000000000003274","article-title":"Cuffless blood pressure devices: the gap between patient acceptability and need for validation.","volume":"40","author":"Gnanenthiran","year":"2022","journal-title":"J Hypertens"},{"key":"hrv250001r44","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1016\/j.hlpt.2018.10.011","article-title":"Technology adoption potential of medical devices: the case of wearable sensor products for pervasive care in neurosurgery and orthopedics.","volume":"7","author":"Hogaboam","year":"2018","journal-title":"Health Policy Technol"},{"key":"hrv250001r45","doi-asserted-by":"publisher","DOI":"10.1016\/j.pecinn.2023.100171","article-title":"Patients\u2019 perspectives on digital health tools.","volume":"2","author":"Madanian","year":"2023","journal-title":"PEC Innov"},{"issue":"2","key":"hrv250001r46","doi-asserted-by":"publisher","first-page":"1","DOI":"10.7309\/jmtm.6.2.1","article-title":"Patient-oriented health technologies: patients\u2019 perspectives and use.","volume":"6","author":"Bauer","year":"2017","journal-title":"J Mob Technol Med"},{"key":"hrv250001r47","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1038\/s41746-019-0132-y","article-title":"Patients\u2019 views of wearable devices and AI in health care: findings from the ComPaRe e-cohort.","volume":"2","author":"Tran","year":"2019","journal-title":"NPJ Digit Med"},{"issue":"7","key":"hrv250001r48","doi-asserted-by":"publisher","first-page":"1638","DOI":"10.1038\/s41440-023-01259-1","article-title":"Current realities of home blood pressure monitoring from physicians\u2019 perspectives: results from Asia HBPM survey 2020.","volume":"46","author":"Wang","year":"2023","journal-title":"Hypertens Res"},{"issue":"1","key":"hrv250001r50","doi-asserted-by":"publisher","DOI":"10.2196\/14512","article-title":"Back to the future: achieving health equity through health informatics and digital health.","volume":"8","author":"Brewer","year":"2020","journal-title":"JMIR Mhealth Uhealth"},{"issue":"9","key":"hrv250001r51","doi-asserted-by":"publisher","first-page":"1372","DOI":"10.1093\/europace\/euac052","article-title":"Wearables, telemedicine, and artificial intelligence in arrhythmias and heart failure: proceedings of the European Society of Cardiology Cardiovascular Round Table.","volume":"24","author":"Leclercq","year":"2022","journal-title":"Europace"},{"issue":"4","key":"hrv250001r52","doi-asserted-by":"publisher","first-page":"e42","DOI":"10.1161\/CIR.0000000000000803","article-title":"Self-measured blood pressure monitoring at home: a joint policy statement from the American Heart Association and American Medical Association.","volume":"142","author":"Shimbo","year":"2020","journal-title":"Circulation"},{"issue":"10","key":"hrv250001r53","doi-asserted-by":"publisher","first-page":"778","DOI":"10.7326\/M15-2223","article-title":"Screening for high blood pressure in adults: US Preventive Services Task Force recommendation statement.","volume":"163","author":"Siu","year":"2015","journal-title":"Ann Intern Med"},{"issue":"6","key":"hrv250001r54","doi-asserted-by":"publisher","first-page":"1269","DOI":"10.1161\/HYP.0000000000000066","article-title":"2017 ACC\/AHA\/AAPA\/ABC\/ACPM\/AGS\/APhA\/ASH\/ASPC\/NMA\/PCNA guideline for the prevention, detection, evaluation, and management of high blood pressure in adults: executive summary: a report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines.","volume":"71","author":"Whelton","year":"2018","journal-title":"Hypertension"},{"issue":"9","key":"hrv250001r55","doi-asserted-by":"publisher","first-page":"1721","DOI":"10.1097\/HJH.0000000000000673","article-title":"Home blood pressure monitoring: Australian Expert Consensus Statement.","volume":"33","author":"Sharman","year":"2015","journal-title":"J Hypertens"},{"issue":"12","key":"hrv250001r56","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1038\/jhh.2010.54","article-title":"European Society of Hypertension practice guidelines for home blood pressure monitoring.","volume":"24","author":"Parati","year":"2010","journal-title":"J Hum Hypertens"},{"issue":"10","key":"hrv250001r57","doi-asserted-by":"publisher","DOI":"10.2196\/14706","article-title":"Validation and acceptability of a cuffless wrist-worn wearable blood pressure monitoring device among users and health care professionals: mixed-methods study.","volume":"7","author":"Islam","year":"2019","journal-title":"JMIR Mhealth Uhealth"},{"issue":"7","key":"hrv250001r58","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1093\/ajh\/hpad021","article-title":"Perspectives and experiences of self-monitoring of blood pressure among patients with hypertension: a systematic review of qualitative studies.","volume":"36","author":"Natale","year":"2023","journal-title":"Am J Hypertens"},{"issue":"9","key":"hrv250001r59","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1016\/j.jash.2017.06.012","article-title":"Barriers to conducting ambulatory and home blood pressure monitoring during hypertension screening in the US.","volume":"11","author":"Kronish","year":"2017","journal-title":"J Am Soc Hypertens"},{"issue":"5","key":"hrv250001r60","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1093\/ajh\/hpac017","article-title":"Cuffless blood pressure devices.","volume":"35","author":"Bradley","year":"2022","journal-title":"Am J Hypertens"},{"issue":"8","key":"hrv250001r62","doi-asserted-by":"publisher","first-page":"e131","DOI":"10.1161\/HYPERTENSIONAHA.123.21412","article-title":"Trends in ambulatory blood pressure monitoring in five high-volume medical centers.","volume":"80","author":"Juraschek","year":"2023","journal-title":"Hypertension"},{"issue":"15","key":"hrv250001r63","doi-asserted-by":"publisher","first-page":"1384","DOI":"10.1056\/NEJMp2033275","article-title":"Remote patient monitoring\u2014overdue or overused?","volume":"384","author":"Mecklai","year":"2021","journal-title":"N Engl J Med"},{"issue":"1","key":"hrv250001r64","doi-asserted-by":"publisher","DOI":"10.1093\/jamiaopen\/ooac111","article-title":"Remote physiologic monitoring for hypertension in primary care: a prospective pragmatic pilot study in electronic health records using propensity score matching.","volume":"6","author":"Petito","year":"2023","journal-title":"JAMIA Open"},{"key":"hrv250001r65","doi-asserted-by":"publisher","DOI":"10.2196\/49003","article-title":"Digital health reimbursement strategies of 8 European countries and Israel: scoping review and policy mapping.","volume":"11","author":"van Kessel","year":"2023","journal-title":"JMIR Mhealth Uhealth"},{"issue":"8","key":"hrv250001r66","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1093\/ajh\/hpy062","article-title":"Patient barriers and facilitators to ambulatory and home blood pressure monitoring: a qualitative study.","volume":"31","author":"Carter","year":"2018","journal-title":"Am J Hypertens"},{"issue":"7","key":"hrv250001r67","doi-asserted-by":"publisher","first-page":"680","DOI":"10.1001\/jama.2021.24464","article-title":"Validation status of blood pressure measuring devices sold globally.","volume":"327","author":"Picone","year":"2022","journal-title":"JAMA"},{"issue":"3","key":"hrv250001r68","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1038\/s41371-022-00670-4","article-title":"Perceptions of pharmacists on the quality of automated blood pressure devices: a national survey.","volume":"37","author":"Picone","year":"2023","journal-title":"J Hum Hypertens"},{"issue":"2","key":"hrv250001r69","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1161\/HYPERTENSIONAHA.118.11990","article-title":"History and justification of a national blood pressure measurement validated device listing.","volume":"73","author":"Cohen","year":"2019","journal-title":"Hypertension"},{"issue":"2","key":"hrv250001r70","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1038\/s41371-022-00747-0","article-title":"The urgency to regulate validation of automated blood pressure measuring devices: a policy statement and call to action from the world hypertension league.","volume":"37","author":"Sharman","year":"2023","journal-title":"J Hum Hypertens"},{"issue":"12","key":"hrv250001r71","doi-asserted-by":"publisher","first-page":"7445","DOI":"10.1364\/BOE.439893","article-title":"Monte Carlo analysis of optical heart rate sensors in commercial wearables: the effect of skin tone and obesity on the photoplethysmography (PPG) signal.","volume":"12","author":"Ajmal","year":"2021","journal-title":"Biomed Opt Express"},{"issue":"1","key":"hrv250001r72","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s40885-020-00158-8","article-title":"Smartphone\/smartwatch-based cuffless blood pressure measurement: a position paper from the Korean Society of Hypertension.","volume":"27","author":"Lee","year":"2021","journal-title":"Clin Hypertens"},{"issue":"6","key":"hrv250001r73","doi-asserted-by":"publisher","first-page":"1164","DOI":"10.1161\/HYPERTENSIONAHA.117.10647","article-title":"Performance of a blood pressure smartphone app in pregnant women: the iPARR trial (iPhone App Compared With Standard RR Measurement).","volume":"71","author":"Raichle","year":"2018","journal-title":"Hypertension"},{"issue":"11","key":"hrv250001r74","doi-asserted-by":"publisher","first-page":"1616","DOI":"10.1111\/jch.13710","article-title":"STRIDE BP international initiative for accurate blood pressure measurement: systematic review of published validation studies of blood pressure measuring devices.","volume":"21","author":"Stergiou","year":"2019","journal-title":"J Clin Hypertens (Greenwich)"},{"issue":"17","key":"hrv250001r75","doi-asserted-by":"publisher","first-page":"e484","DOI":"10.1161\/CIR.0000000000000596","article-title":"2017 ACC\/AHA\/AAPA\/ABC\/ACPM\/AGS\/APhA\/ASH\/ASPC\/NMA\/PCNA guideline for the prevention, detection, evaluation, and management of high blood pressure in adults: a report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines.","volume":"138","author":"Whelton","year":"2018","journal-title":"Circulation"},{"issue":"6","key":"hrv250001r76","doi-asserted-by":"publisher","first-page":"1334","DOI":"10.1161\/HYPERTENSIONAHA.120.15026","article-title":"2020 International Society of Hypertension global hypertension practice guidelines.","volume":"75","author":"Unger","year":"2020","journal-title":"Hypertension"},{"issue":"12","key":"hrv250001r77","doi-asserted-by":"publisher","first-page":"1874","DOI":"10.1097\/HJH.0000000000003480","article-title":"2023 ESH guidelines for the management of arterial hypertension\u2014The Task Force for the management of arterial hypertension of the European Society of Hypertension: endorsed by the International Society of Hypertension (ISH) and the European Renal Association (ERA).","volume":"41","author":"Mancia","year":"2023","journal-title":"J Hypertens"},{"issue":"38","key":"hrv250001r78","doi-asserted-by":"publisher","first-page":"3912","DOI":"10.1093\/eurheartj\/ehae178","article-title":"2024 ESC Guidelines for the management of elevated blood pressure and hypertension.","volume":"45","author":"McEvoy","year":"2024","journal-title":"Eur Heart J"},{"key":"hrv250001r2","volume-title":"Global Report on Hypertension: The Race Against a Silent Killer","author":"World Health Organization","year":"2023"},{"key":"hrv250001r49","volume-title":"Digital Literacy","author":"Gilster","year":"1997"},{"key":"hrv250001r4","unstructured":"Million Hearts. Estimated hypertension prevalence, treatment, and control estimates among US adults. Accessed August 16, 2023. https:\/\/www.millionhearts.hhs.gov\/data-reports\/hypertension-prevalence.html"},{"key":"hrv250001r8","unstructured":"Grand View Research. Wearable Technology Market Size & Trends. Accessed August 16, 2023. https:\/\/www.grandviewresearch.com\/industry-analysis\/wearable-technology-market"},{"key":"hrv250001r35","unstructured":"ISO. N?ninvasive sphygmomanometers. Accessed July 26, 2023. https:\/\/www.iso.org\/standard\/71161.html"},{"key":"hrv250001r61","unstructured":"Central Intelligence Agency. Real GDP (purchasing power parity). Accessed August 20, 2023. https:\/\/www.cia.gov\/the-world-factbook\/field\/real-gdp-purchasing-power-parity\/country-comparison\/"}],"container-title":["JAMA Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/jamanetwork.com\/journals\/jamacardiology\/articlepdf\/2832857\/jamacardiology_yang_2025_rv_250001_1749063398.2659.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,11]],"date-time":"2025-06-11T15:01:01Z","timestamp":1749654061000},"score":1,"resource":{"primary":{"URL":"https:\/\/jamanetwork.com\/journals\/jamacardiology\/fullarticle\/2832857"}},"subtitle":["A Narrative Review"],"short-title":[],"issued":{"date-parts":[[2025,6,1]]},"references-count":78,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,6,1]]}},"URL":"https:\/\/doi.org\/10.1001\/jamacardio.2025.0662","relation":{},"ISSN":["2380-6583"],"issn-type":[{"value":"2380-6583","type":"print"}],"subject":[],"published":{"date-parts":[[2025,6,1]]}}}