{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T07:27:58Z","timestamp":1793258878568,"version":"4.5.0"},"reference-count":20,"publisher":"American Medical Association (AMA)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JAMA Netw Open"],"abstract":"<jats:sec id=\"ab-zoi251544-4\">\n                    <jats:title>Importance<\/jats:title>\n                    <jats:p>Percutaneous left atrial appendage occlusion (LAAO) is frequently performed with an interventional echocardiographer (IE) in close proximity to the patient and radiation source, increasing the risk for occupational radiation exposure. Yet optimal radiation shielding methods for IEs remain unknown.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"ab-zoi251544-5\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To assess whether using a suspended lead suit reduces IE radiation dose compared with traditional lead apron shielding during LAAO procedures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"ab-zoi251544-6\">\n                    <jats:title>Design, Setting, and Participants<\/jats:title>\n                    <jats:p>In this blinded cross-sectional study, IE radiation exposure data were prospectively collected during all LAAO procedures conducted for adults at a single quaternary care center from February 21 to August 22, 2023. Head-level dosimeters were worn by IEs who were using suspended lead suits during sequential LAAO procedures conducted at the center.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"ab-zoi251544-7\">\n                    <jats:title>Exposures<\/jats:title>\n                    <jats:p>Use of a suspended lead suit or traditional lead apron radiation protection device.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"ab-zoi251544-8\">\n                    <jats:title>Main Outcomes and Measures<\/jats:title>\n                    <jats:p>The primary outcome was measured personal dose equivalents at head level to IEs per case using real-time radiation dosimeters. Dosimeter-derived physician radiation doses and procedural radiation (dose area product) were compared with a control group of 30 sequential historical LAAO cases performed with IEs wearing traditional lead aprons from July 1, 2016, to January 31, 2018.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"ab-zoi251544-9\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Overall, 125 patients (mean [SD] age, 78 [8] years; 77 [61.6%] male) were included. Among 95 cases in which IEs used suspended lead suits, the median (IQR) radiation dose was 0.0 (0.0-0.3) \u03bcSv, which was significantly lower than 30 cases in which IEs wore traditional lead aprons (median [IQR], 10.6 [5.8-24.1] \u03bcSv;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&amp;amp;lt;\u2009.001). Radiation doses were undetectable in 60% of IEs (57of 95) using suspended lead suits compared with 0% of IEs (0 of 30) using traditional lead aprons (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&amp;amp;lt;\u2009.001). Radiation doses of at least 20 \u03bcSv were observed in 0 of 95 cases (0%) with suspended lead suits vs 9 of 30 cases (30%) with traditional lead aprons (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&amp;amp;lt;\u2009.001). Similar associations were noted in exploratory analyses adjusting IE radiation doses for procedural dose area product (mean [IQR], 0.0 [0.0-0.0] \u03bcSv\/Gy\u2009\u00d7\u2009cm\n                      <jats:sup>2<\/jats:sup>\n                      ) for suspended lead suits vs traditional lead aprons (mean [IQR], 0.6 [0.3-1.0] \u03bcSv\/Gy\u2009\u00d7\u2009cm\n                      <jats:sup>2<\/jats:sup>\n                      ;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&amp;amp;lt;\u2009.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"ab-zoi251544-10\">\n                    <jats:title>Conclusions and Relevance<\/jats:title>\n                    <jats:p>In this cross-sectional study, the use of suspended lead suits was associated with large reductions in head-level radiation doses to IEs compared with the use of traditional lead aprons during LAAO cases. These findings have important ramifications for the risk of occupational radiation exposure to IEs and potential shielding mechanisms during structural heart interventions.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1001\/jamanetworkopen.2025.58134","type":"journal-article","created":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T15:00:21Z","timestamp":1773241221000},"page":"e2558134","source":"Crossref","is-referenced-by-count":2,"title":["Suspended Lead Suits and Radiation Exposure in Interventional Echocardiographers"],"prefix":"10.1001","volume":"9","author":[{"given":"David A.","family":"McNamara","sequence":"first","affiliation":[{"name":"Frederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey M.","family":"Decker","sequence":"additional","affiliation":[{"name":"Frederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael W.","family":"McNamara","sequence":"additional","affiliation":[{"name":"Frederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamad A.","family":"Kenaan","sequence":"additional","affiliation":[{"name":"Frederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David M.","family":"Cameron","sequence":"additional","affiliation":[{"name":"Frederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stacie","family":"VanOosterhout","sequence":"additional","affiliation":[{"name":"Corewell Health Research Institute, Corewell Health, Grand Rapids, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jessica L.","family":"Parker","sequence":"additional","affiliation":[{"name":"Corewell Health Research Institute, Corewell Health, Grand Rapids, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan D.","family":"Madder","sequence":"additional","affiliation":[{"name":"Frederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan"},{"name":"Department of Cardiovascular Medicine, William Beaumont University Hospital, Corewell Health East, Royal Oak, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10","published-online":{"date-parts":[[2026,3,11]]},"reference":[{"issue":"1","key":"zoi251544r1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/ccd.27114","article-title":"Risk of cataract among interventional cardiologists and catheterization lab staff: a systematic review and meta-analysis.","volume":"90","author":"Elmaraezy","year":"2017","journal-title":"Catheter Cardiovasc Interv"},{"issue":"3","key":"zoi251544r2","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1159\/000342458","article-title":"Radiation-induced eye lens changes and risk for cataract in interventional cardiology.","volume":"123","author":"Ciraj-Bjelac","year":"2012","journal-title":"Cardiology"},{"issue":"4","key":"zoi251544r3","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1016\/j.jcin.2014.12.233","article-title":"Subclinical carotid atherosclerosis and early vascular aging from long-term low-dose ionizing radiation exposure: a genetic, telomere, and vascular ultrasound study in cardiac catheterization laboratory staff.","volume":"8","author":"Andreassi","year":"2015","journal-title":"JACC Cardiovasc Interv"},{"issue":"9","key":"zoi251544r4","doi-asserted-by":"publisher","first-page":"1368","DOI":"10.1016\/j.amjcard.2012.12.060","article-title":"Brain and neck tumors among physicians performing interventional procedures.","volume":"111","author":"Roguin","year":"2013","journal-title":"Am J Cardiol"},{"issue":"7","key":"zoi251544r5","doi-asserted-by":"publisher","DOI":"10.1001\/jamanetworkopen.2022.20597","article-title":"Comparison of radiation exposure among interventional echocardiographers, interventional cardiologists, and sonographers during percutaneous structural heart interventions.","volume":"5","author":"McNamara","year":"2022","journal-title":"JAMA Netw Open"},{"issue":"4","key":"zoi251544r6","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1002\/ccd.30047","article-title":"Suspended lead suit and physician radiation doses during coronary angiography.","volume":"99","author":"Salcido-Rios","year":"2022","journal-title":"Catheter Cardiovasc Interv"},{"issue":"3","key":"zoi251544r7","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1016\/j.carrev.2016.12.011","article-title":"Impact of robotics and a suspended lead suit on physician radiation exposure during percutaneous coronary intervention.","volume":"18","author":"Madder","year":"2017","journal-title":"Cardiovasc Revasc Med"},{"issue":"2","key":"zoi251544r8","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1016\/j.jcin.2017.07.026","article-title":"Radiation exposure among scrub technologists and nurse circulators during cardiac catheterization: the impact of accessory lead shields.","volume":"11","author":"Madder","year":"2018","journal-title":"JACC Cardiovasc Interv"},{"issue":"5","key":"zoi251544r9","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1002\/ccd.26007","article-title":"Comparison of radiation dose between different fluoroscopy systems in the modern catheterization laboratory: results from bench testing using an anthropomorphic phantom.","volume":"86","author":"Christopoulos","year":"2015","journal-title":"Catheter Cardiovasc Interv"},{"issue":"4","key":"zoi251544r10","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1016\/j.cardfail.2022.09.005","article-title":"Physician radiation exposure during endomyocardial biopsy and right heart catheterization.","volume":"29","author":"Loyaga-Rendon","year":"2023","journal-title":"J Card Fail"},{"issue":"10","key":"zoi251544r11","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1016\/j.jcin.2013.05.012","article-title":"Physicians\u2019 radiation exposure in the catheterization lab: does the type of procedure matter?","volume":"6","author":"Ingwersen","year":"2013","journal-title":"JACC Cardiovasc Interv"},{"issue":"11","key":"zoi251544r12","doi-asserted-by":"publisher","first-page":"1246","DOI":"10.1016\/j.jacc.2018.01.024","article-title":"Radiation exposure of operators performing transesophageal echocardiography during percutaneous structural cardiac interventions.","volume":"71","author":"Crowhurst","year":"2018","journal-title":"J Am Coll Cardiol"},{"issue":"21","key":"zoi251544r13","doi-asserted-by":"publisher","first-page":"2488","DOI":"10.1016\/j.jcin.2024.08.048","article-title":"Institutional variation in patient radiation doses during transcatheter valve interventions: a statewide experience.","volume":"17","author":"McNamara","year":"2024","journal-title":"JACC Cardiovasc Interv"},{"issue":"2","key":"zoi251544r14","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.123.013502","article-title":"Statewide initiative to reduce patient radiation doses during percutaneous coronary intervention.","volume":"17","author":"Madder","year":"2024","journal-title":"Circ Cardiovasc Interv"},{"issue":"4","key":"zoi251544r15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacadv.2024.100863","article-title":"Radiation exposure, training, and safety in cardiology.","volume":"3","author":"Tamirisa","year":"2024","journal-title":"JACC Adv"},{"issue":"7","key":"zoi251544r16","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1016\/j.echo.2024.03.020","article-title":"Radiation risk in interventional echocardiography: yet another barrier for women in cardiology.","volume":"37","author":"Quader","year":"2024","journal-title":"J Am Soc Echocardiogr"},{"issue":"6","key":"zoi251544r17","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1093\/ehjci\/jeae086","article-title":"EACVI survey on radiation exposure in interventional echocardiography.","volume":"25","author":"Galli","year":"2024","journal-title":"Eur Heart J Cardiovasc Imaging"},{"issue":"7","key":"zoi251544r18","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1016\/j.echo.2024.03.002","article-title":"Radiation exposure to the interventional echocardiographers and sonographers: a call to action.","volume":"37","author":"Garcia-Sayan","year":"2024","journal-title":"J Am Soc Echocardiogr"},{"issue":"1","key":"zoi251544r19","article-title":"Radiation exposure using rampart vs standard lead aprons and shields during invasive cardiovascular procedures.","volume":"3","author":"Lisko","year":"2023","journal-title":"J Soc Cardiovasc Angiogr Interv"},{"issue":"1","key":"zoi251544r20","article-title":"Radiation doses to the entire catheterization laboratory team with a novel radiation protection device.","volume":"3","author":"Parikh","year":"2023","journal-title":"J Soc Cardiovasc Angiogr Interv"}],"container-title":["JAMA Network Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/jamanetwork.com\/journals\/jamanetworkopen\/articlepdf\/2846210\/mcnamara_2026_oi_251544_1772645499.54239.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T15:00:22Z","timestamp":1773241222000},"score":1,"resource":{"primary":{"URL":"https:\/\/jamanetwork.com\/journals\/jamanetworkopen\/fullarticle\/2846210"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,11]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,3,2]]}},"URL":"https:\/\/doi.org\/10.1001\/jamanetworkopen.2025.58134","relation":{},"ISSN":["2574-3805"],"issn-type":[{"value":"2574-3805","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,11]]}}}