{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,10,21]],"date-time":"2022-10-21T04:59:32Z","timestamp":1666328372364},"reference-count":12,"publisher":"American Medical Association (AMA)","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JAMA Ophthalmol"],"published-print":{"date-parts":[[2022,10,1]]},"abstract":"<jats:sec id=\"ab-ebr220014-4\"><jats:title>Importance<\/jats:title><jats:p>Ganglion cell analysis (GCA) of ocular coherence tomography (OCT) imaging is routinely used to detect and monitor glaucomatous damage of the ganglion cell complex in the macula. The GCA printout provides qualitative and quantitative data about the macular ganglion cell\u2013inner plexiform layer and a single B-scan of the retina through the fovea. However, the full macular cube scan, including all 128 B-scans, is available for review. The macular cube scan provides considerable information about nonglaucomatous ocular pathology that may be missed if clinicians review only the GCA printout.<\/jats:p><\/jats:sec><jats:sec id=\"ab-ebr220014-5\"><jats:title>Objective<\/jats:title><jats:p>To determine the frequency and type of nonglaucomatous macular findings that are observable in the full macular cube scan but not the GCA printout.<\/jats:p><\/jats:sec><jats:sec id=\"ab-ebr220014-6\"><jats:title>Design, Setting, and Participants<\/jats:title><jats:p>A retrospective cross-sectional analysis of GCA printouts and full macular cube scans to detect nonglaucomatous macular pathology at a tertiary care academic center. Consecutive patients undergoing ganglion cell complex  imaging during routine glaucoma evaluations over a 1-week period in a multi-clinician glaucoma clinic.<\/jats:p><\/jats:sec><jats:sec id=\"ab-ebr220014-7\"><jats:title>Main Outcomes and Measures<\/jats:title><jats:p>The prevalence and type of nonglaucomatous macular pathology visible on the GCA printout or macular cube scan.<\/jats:p><\/jats:sec><jats:sec id=\"ab-ebr220014-8\"><jats:title>Results<\/jats:title><jats:p>Among 105 patients (mean (SD) age, 67 (15.46) years; 63 [60%] female and 42 [40%] male) 201 eyes were imaged (64 [31.7%] with suspected glaucoma, 126 [62.4%] with open-angle glaucoma, 6 [3.0%] with closed-angle glaucoma, and 6 [3.0%] with other glaucoma). GCA printouts and macular cube scans revealed nonglaucomatous macular pathology in 65 eyes (32.2%). Of these, 25 eyes (38.5%) included findings that were not visible on the GCA printout. Of the cases not visible on the printout, 16 eyes (64.0% ) included macular pathology that required further evaluation.<\/jats:p><\/jats:sec><jats:sec id=\"ab-ebr220014-9\"><jats:title>Conclusions and Relevance<\/jats:title><jats:p>The findings indicate that nonglaucomatous macular pathology may be missed based on GCA printouts alone. While it may be beneficial to review the full macular cube to detect potentially vision-threatening disease and ensure proper patient care, this study cannot determine if this missed pathology affects clinical outcomes.<\/jats:p><\/jats:sec>","DOI":"10.1001\/jamaophthalmol.2022.3450","type":"journal-article","created":{"date-parts":[[2022,9,8]],"date-time":"2022-09-08T15:32:59Z","timestamp":1662651179000},"page":"1002","source":"Crossref","is-referenced-by-count":0,"title":["Detection of Nonglaucomatous Macula Findings With Ganglion Cell Analysis Printouts vs Full Macular Cube Scans"],"prefix":"10.1001","volume":"140","author":[{"given":"Maya","family":"Yamane","sequence":"first","affiliation":[{"name":"Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California, San Diego"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henry","family":"Ferreyra","sequence":"additional","affiliation":[{"name":"Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California, San Diego"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benjamin Y.","family":"Xu","sequence":"additional","affiliation":[{"name":"Roski Eye Institute, Department of Ophthalmology, Keck School of Medicine at the University of Southern California, Los Angeles"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert N.","family":"Weinreb","sequence":"additional","affiliation":[{"name":"Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California, San Diego"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew S.","family":"Camp","sequence":"additional","affiliation":[{"name":"Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California, San Diego"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"10","reference":[{"issue":"2","key":"ebr220014r1","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1111\/ceo.1995.23.issue-2","article-title":"Ganglion cell death in glaucoma: pathology recapitulates ontogeny.","volume":"23","author":"Quigley","year":"1995","journal-title":"Aust N Z J Ophthalmol"},{"issue":"1","key":"ebr220014r2","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1002\/(ISSN)1096-9861","article-title":"Topography of ganglion cells in human retina.","volume":"300","author":"Curcio","year":"1990","journal-title":"J Comp Neurol"},{"key":"ebr220014r3","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1016\/j.ajo.2017.03.008","article-title":"Comparing the rates of retinal nerve fiber layer and ganglion cell-inner plexiform layer loss in healthy eyes and in glaucoma eyes.","volume":"178","author":"Hammel","year":"2017","journal-title":"Am J Ophthalmol"},{"issue":"2","key":"ebr220014r4","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/S0161-6420(98)92743-9","article-title":"Quantitative detection of glaucomatous damage at the posterior pole by retinal thickness mapping. a pilot study.","volume":"105","author":"Zeimer","year":"1998","journal-title":"Ophthalmology"},{"issue":"6","key":"ebr220014r5","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1016\/j.ajo.2013.08.001","article-title":"Macular ganglion cell\/inner plexiform layer measurements by spectral domain optical coherence tomography for detection of early glaucoma and comparison to retinal nerve fiber layer measurements.","volume":"156","author":"Nouri-Mahdavi","year":"2013","journal-title":"Am J Ophthalmol"},{"issue":"4","key":"ebr220014r6","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1016\/j.ophtha.2003.06.028","article-title":"Comparison of the clinical diagnosis of diabetic macular edema with diagnosis by optical coherence tomography.","volume":"111","author":"Browning","year":"2004","journal-title":"Ophthalmology"},{"key":"ebr220014r7","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.ajo.2020.08.018","article-title":"Impact of artifacts from optical coherence tomography retinal nerve fiber layer and macula scans on detection of glaucoma progression.","volume":"221","author":"Li","year":"2021","journal-title":"Am J Ophthalmol"},{"issue":"4","key":"ebr220014r8","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1001\/jamaophthalmol.2013.7974","article-title":"Artifacts in spectral-domain optical coherence tomography measurements in glaucoma.","volume":"132","author":"Asrani","year":"2014","journal-title":"JAMA Ophthalmol"},{"issue":"12","key":"ebr220014r9","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0206684","article-title":"Prevalence and type of artefact with spectral domain optical coherence tomography macular ganglion cell imaging in glaucoma surveillance.","volume":"13","author":"Awadalla","year":"2018","journal-title":"PLoS One"},{"issue":"6","key":"ebr220014r10","doi-asserted-by":"publisher","first-page":"3995","DOI":"10.1167\/iovs.14-14438","article-title":"Patterns of macular ganglion cell abnormalities in various ocular conditions.","volume":"55","author":"Hwang","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"1","key":"ebr220014r11","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/S0161-6420(02)01443-4","article-title":"Five-year cumulative incidence and progression of epiretinal membranes: the Blue Mountains Eye Study.","volume":"110","author":"Fraser-Bell","year":"2003","journal-title":"Ophthalmology"},{"issue":"1","key":"ebr220014r12","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1148\/radiology.175.1.2179991","article-title":"When is it malpractice to miss lung cancer on chest radiographs?","volume":"175","author":"Potchen","year":"1990","journal-title":"Radiology"}],"container-title":["JAMA Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/jamanetwork.com\/journals\/jamaophthalmology\/articlepdf\/2795942\/jamaophthalmology_yamane_2022_br_220014_1666118422.29505.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,20]],"date-time":"2022-10-20T15:04:33Z","timestamp":1666278273000},"score":1,"resource":{"primary":{"URL":"https:\/\/jamanetwork.com\/journals\/jamaophthalmology\/fullarticle\/2795942"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,1]]},"references-count":12,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2022,10,1]]}},"URL":"https:\/\/doi.org\/10.1001\/jamaophthalmol.2022.3450","relation":{},"ISSN":["2168-6165"],"issn-type":[{"value":"2168-6165","type":"print"}],"subject":[],"published":{"date-parts":[[2022,10,1]]}}}