{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T16:01:55Z","timestamp":1791475315076,"version":"4.3.4"},"reference-count":16,"publisher":"American Medical Association (AMA)","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JAMA Ophthalmol"],"published-print":{"date-parts":[[2023,10,1]]},"abstract":"<jats:sec id=\"ab-eoi230052-4\"><jats:title>Importance<\/jats:title><jats:p>The current clinical criterion standard for measuring abnormal eyeball protrusion is still the historic Hertel exophthalmometer, which is prone to reading errors. Therefore, a smartphone application has been developed to measure exophthalmos.<\/jats:p><\/jats:sec><jats:sec id=\"ab-eoi230052-5\"><jats:title>Objective<\/jats:title><jats:p>To evaluate a relatively simple noninvasive measurement method for exophthalmos using a smartphone.<\/jats:p><\/jats:sec><jats:sec id=\"ab-eoi230052-6\"><jats:title>Design, Setting, and Participants<\/jats:title><jats:p>This cross-sectional study compared smartphone exophthalmometry with the existing reference standard, the Hertel exophthalmometer, or a professional high-resolution 3-dimensional scanner. Participants were patients with exophthalmos due to Graves orbitopathy and other intraorbital conditions and healthy volunteers who were recruited between June 2019 and January 2022 from the Department of Ophthalmology, University Hospital Zurich.<\/jats:p><\/jats:sec><jats:sec id=\"ab-eoi230052-7\"><jats:title>Interventions<\/jats:title><jats:p>All participants were examined twice by 3 different operators using 3 different methods (smartphone, high-resolution scanner, or Hertel exophthalmometer) at an interval of a minimum of 2 weeks or after exophthalmos-changing treatment.<\/jats:p><\/jats:sec><jats:sec id=\"ab-eoi230052-8\"><jats:title>Main Outcome Measures<\/jats:title><jats:p>Accuracy and precision, test-retest reliability, and interoperator reliability of eyeball protrusion measurements obtained with the smartphone compared to the Hertel exophthalmometer and the high-resolution face scanner.<\/jats:p><\/jats:sec><jats:sec id=\"ab-eoi230052-9\"><jats:title>Results<\/jats:title><jats:p>Of 39 participants, 23 patients (median [IQR] age, 54 [44-59] years; 15 [65%] female and 8 [35%] male) showed a mean difference in eyeball protrusion of 3.3 mm and 16 healthy volunteers (median [IQR] age, 32 [30-37] years; 11 [69%] female and 5 [31%] male) of 0.8 mm without any significant difference between the 3 methods. Accuracy and precision agreement between exophthalmos measures with the smartphone and the Hertel exophthalmometer showed an intraclass correlation coefficient (ICC) of 0.89 (95% CI, 0.80-0.94) and 0.93 (95% CI, 0.83-0.97) for the high-resolution scanner. Interoperator agreement was highest for the high-resolution scanner (ICC, 0.99 [95% CI, 0.98-0.99]), followed by the smartphone (ICC, 0.95 [95% CI, 0.92-0.97]) and the Hertel exophthalmometer (ICC, 0.91 [95% CI, 0.85-0.95]). Test retest reliability was similarly high for the smartphone (ICC, 0.93 [95% CI, 0.82-0.95]), the Hertel exophthalmometer (ICC, 0.92 [95% CI, 0.83-0.96]), and the high-resolution scanner (ICC, 0.95 [95% CI, 0.89-0.97]).<\/jats:p><\/jats:sec><jats:sec id=\"ab-eoi230052-10\"><jats:title>Conclusions and Relevance<\/jats:title><jats:p>The findings of this study demonstrate relatively high accuracy and precision, interoperator reliability, and test-retest reliability for smartphone exophthalmometry. These data support the use of a smartphone in place of a Hertel exophthalmometer for measuring exophthalmos in the future.<\/jats:p><\/jats:sec>","DOI":"10.1001\/jamaophthalmol.2023.4044","type":"journal-article","created":{"date-parts":[[2023,9,21]],"date-time":"2023-09-21T15:02:02Z","timestamp":1695308522000},"page":"974","source":"Crossref","is-referenced-by-count":9,"title":["Using Smartphone Exophthalmometry to Measure Eyeball Protrusion"],"prefix":"10.1001","volume":"141","author":[{"given":"Todor","family":"Popov","sequence":"first","affiliation":[{"name":"Department of Neurology, University Hospital Zurich, University of Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabienne C.","family":"Fierz","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University Hospital Zurich, University of Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.","family":"Bockisch","sequence":"additional","affiliation":[{"name":"Department of Neurology, University Hospital Zurich, University of Zurich, Zurich, Switzerland"},{"name":"Department of Ophthalmology, University Hospital Zurich, University of Zurich, Zurich, Switzerland"},{"name":"Department of Otorhinolaryngology, Head & Neck Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Konrad P.","family":"Weber","sequence":"additional","affiliation":[{"name":"Department of Neurology, University Hospital Zurich, University of Zurich, Zurich, Switzerland"},{"name":"Department of Ophthalmology, University Hospital Zurich, University of Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10","reference":[{"issue":"3","key":"eoi230052r1","article-title":"Etiologies of proptosis: a review.","volume":"6","author":"Topilow","year":"2020","journal-title":"Intern Med Rev (Wash D C)"},{"key":"eoi230052r2","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1007\/BF01885286","article-title":"Ein einfaches exophthalmometer.","volume":"60","author":"Hertel","year":"1905","journal-title":"Albrecht von Graefes Archiv f\u00fcr Ophthalmologie"},{"issue":"9","key":"eoi230052r3","doi-asserted-by":"publisher","first-page":"1177","DOI":"10.1016\/S0161-6420(85)33880-0","article-title":"The reliability of Hertel exophthalmometry: observer variation between physician and lay readers.","volume":"92","author":"Musch","year":"1985","journal-title":"Ophthalmology"},{"issue":"6","key":"eoi230052r4","doi-asserted-by":"publisher","first-page":"1290e","DOI":"10.1097\/PRS.0000000000005671","article-title":"Three-dimensional analysis of donor masks for facial transplantation.","volume":"143","author":"Cammarata","year":"2019","journal-title":"Plast Reconstr Surg"},{"issue":"4","key":"eoi230052r5","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1016\/j.jobcr.2019.07.001","article-title":"Scan time, reliability and accuracy of craniofacial measurements using a 3D light scanner.","volume":"9","author":"Franco de S\u00e1 Gomes","year":"2019","journal-title":"J Oral Biol Craniofac Res"},{"key":"eoi230052r6","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.medengphy.2018.11.004","article-title":"Accuracy of 3D surface scanners for clinical torso and spinal deformity assessment.","volume":"63","author":"Grant","year":"2019","journal-title":"Med Eng Phys"},{"issue":"9","key":"eoi230052r7","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0184498","article-title":"Validity and reliability of a novel 3D scanner for assessment of the shape and volume of amputees\u2019 residual limb models.","volume":"12","author":"Seminati","year":"2017","journal-title":"PLoS One"},{"issue":"1","key":"eoi230052r9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1373\/49.1.1","article-title":"Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative: standards for reporting of diagnostic accuracy.","volume":"49","author":"Bossuyt","year":"2003","journal-title":"Clin Chem"},{"issue":"1","key":"eoi230052r10","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.jneumeth.2007.03.024","article-title":"Nonparametric statistical testing of EEG- and MEG-data.","volume":"164","author":"Maris","year":"2007","journal-title":"J Neurosci Methods"},{"key":"eoi230052r12","first-page":"65","article-title":"A simple sequentially rejective multiple test procedure.","volume":"6","author":"Holm","year":"1979","journal-title":"Scand J Stat"},{"issue":"2","key":"eoi230052r13","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1016\/j.ophtha.2004.09.019","article-title":"Anterior chamber width measurement by high-speed optical coherence tomography.","volume":"112","author":"Goldsmith","year":"2005","journal-title":"Ophthalmology"},{"issue":"5","key":"eoi230052r14","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1080\/01676830.2021.1980894","article-title":"Utilizing a mobile platform to obtain quantitative measurements of exophthalmos.","volume":"41","author":"Magazin","year":"2022","journal-title":"Orbit"},{"issue":"2","key":"eoi230052r15","doi-asserted-by":"publisher","first-page":"48","DOI":"10.17116\/oftalma2018134248-52","article-title":"Exophthalmometry with computed tomography [article in Russian].","volume":"134","author":"Gushchina","year":"2018","journal-title":"Vestn Oftalmol"},{"issue":"5","key":"eoi230052r16","doi-asserted-by":"publisher","first-page":"257","DOI":"10.3109\/01676830.2015.1057291","article-title":"Proptosis\u2013correlation and agreement between Hertel exophthalmometry and computed tomography.","volume":"34","author":"Ramli","year":"2015","journal-title":"Orbit"},{"key":"eoi230052r11","volume-title":"The Practice of Business Statistics: Using Data for Decisions","author":"Moore","year":"2009"},{"key":"eoi230052r8","unstructured":"WO2022018271 - method for determining a coronal position of an eye relative to the HEADWIPO. Accessed August 10, 2023. https:\/\/patentscope.wipo.int\/search\/en\/detail.jsf?docId=WO2022018271"}],"container-title":["JAMA Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/jamanetwork.com\/journals\/jamaophthalmology\/articlepdf\/2809651\/jamaophthalmology_popov_2023_oi_230052_1697215826.10587.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,19]],"date-time":"2023-10-19T15:05:15Z","timestamp":1697727915000},"score":1,"resource":{"primary":{"URL":"https:\/\/jamanetwork.com\/journals\/jamaophthalmology\/fullarticle\/2809651"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,1]]},"references-count":16,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2023,10,1]]}},"URL":"https:\/\/doi.org\/10.1001\/jamaophthalmol.2023.4044","relation":{},"ISSN":["2168-6165"],"issn-type":[{"value":"2168-6165","type":"print"}],"subject":[],"published":{"date-parts":[[2023,10,1]]}}}