{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,19]],"date-time":"2026-11-19T14:13:30Z","timestamp":1795097610074,"version":"4.10.3"},"reference-count":27,"publisher":"American Medical Association (AMA)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JAMA Ophthalmol"],"published-print":{"date-parts":[[2025,5,1]]},"abstract":"<jats:sec><jats:title>Importance<\/jats:title><jats:p>Capsular tension ring (CTR) implantation has been shown to reduce intraocular lens (IOL) decentration and tilt in high myopia. However, the effect of CTR implantation in highly myopic eyes on IOL power calculation remains unclear, particularly in new-generation formulas.<\/jats:p><\/jats:sec><jats:sec><jats:title>Objective<\/jats:title><jats:p>To evaluate the influence of CTR implantation on IOL power calculation in highly myopic eyes.<\/jats:p><\/jats:sec><jats:sec><jats:title>Design, Setting, and Participants<\/jats:title><jats:p>This is a prespecified secondary analysis of outcomes of a randomized clinical trial conducted between November 2021 and September 2023 at the Zhongshan Ophthalmic Center in Guangzhou, China. Cataract patients with an axial length (AL) of 26 mm or longer were enrolled and stratified into 3 strata based on AL (stratum 1: AL 26-&amp;amp;lt;28 mm; stratum 2: AL 28-&amp;amp;lt;30 mm; stratum 3: AL \u226530 mm).<\/jats:p><\/jats:sec><jats:sec><jats:title>Interventions<\/jats:title><jats:p>Participants were stratified based on AL and randomized to the CTR group (a C-loop IOL combined with a CTR) or the control group (only a C-loop IOL) within each stratum.<\/jats:p><\/jats:sec><jats:sec><jats:title>Main Outcomes and Measures<\/jats:title><jats:p>Predictive outcomes of 6 new-generation formulas and 4 traditional formulas were evaluated. The arithmetic and absolute prediction error (PE) and the percentages of eyes within \u00b10.25 diopter (D), \u00b10.50 D, \u00b10.75 D, and \u00b11.00 D of PE were analyzed.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>A total of 186 eyes of 186 participants were randomized into the CTR group (93 eyes [50%]) or control group (93 eyes [50%]). Excluding a withdrawal case and 24 eyes with best-corrected visual acuity less than 20\/40, 80 eyes in the CTR group (86.0%) and 81 eyes in the control group (87.1%) were analyzed. Of 161 participants analyzed, overall mean (SD) participant age was 56.7 (10.5) years, and 100 participants (62.1%) were female. No differences were observed in arithmetic PE between the CTR and control groups in any strata. The CTR group showed smaller absolute PE in all new-generation formulas and higher percentage of PE within \u00b10.50 D in the Emmetropia Verifying Optical 2.0, Hoffer QST, LISA, and Pearl-DGS formulas only for eyes with an AL of 30 mm or longer compared with the control group. In traditional formulas, no differences were observed between the 2 groups in any strata.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions and Relevance<\/jats:title><jats:p>In this secondary analysis, CTR implantation in highly myopic eyes did not affect the target refraction and can improve the prediction accuracy of new-generation IOL calculation formulas in eyes with AL of 30 mm or longer. These findings support use of CTR implantation in eyes with an AL of 30 mm or longer.<\/jats:p><\/jats:sec><jats:sec><jats:title>Trial Registration<\/jats:title><jats:p>ClinicalTrials.gov Identifier: <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/www.clinicaltrials.gov\/study\/NCT05161520\">NCT05161520<\/jats:ext-link><\/jats:p><\/jats:sec>","DOI":"10.1001\/jamaophthalmol.2025.0110","type":"journal-article","created":{"date-parts":[[2025,3,20]],"date-time":"2025-03-20T20:49:20Z","timestamp":1742503760000},"page":"373","source":"Crossref","is-referenced-by-count":9,"title":["Capsular Tension Ring Implantation for Intraocular Lens Power Calculation in Highly Myopic Eyes"],"prefix":"10.1001","volume":"143","author":[{"given":"Haowen","family":"Lin","sequence":"first","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Vision Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiaqing","family":"Zhang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Vision Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aixia","family":"Jin","sequence":"additional","affiliation":[{"name":"Shenzhen Eye Institute, Shenzhen Eye Hospital, Jinan University, Shenzhen, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yifan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, The Second People\u2019s Hospital of Foshan, Foshan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Zhang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Vision Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"Jin","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Vision Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yifan","family":"Xu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Vision Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaohang","family":"Xie","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Vision Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaozhang","family":"Qiu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Vision Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boyufei","family":"Dai","sequence":"additional","affiliation":[{"name":"Zhongshan Medical School, Sun Yat-sen University, Guangzhou, Guangdong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuhua","family":"Tan","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Vision Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lixia","family":"Luo","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Vision Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yizhi","family":"Liu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Vision Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10","reference":[{"issue":"6","key":"eoi250004r1","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1167\/iovs.64.6.6","article-title":"IMI-global trends in myopia management attitudes and strategies in clinical practice-2022 update.","volume":"64","author":"Wolffsohn","year":"2023","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"5","key":"eoi250004r2","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1016\/j.ophtha.2016.01.006","article-title":"Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050.","volume":"123","author":"Holden","year":"2016","journal-title":"Ophthalmology"},{"issue":"4","key":"eoi250004r3","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1167\/iovs.61.4.49","article-title":"The complications of myopia: a review and meta-analysis.","volume":"61","author":"Haarman","year":"2020","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"2","key":"eoi250004r4","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1016\/j.ophtha.2012.07.065","article-title":"Differential associations of myopia with major age-related eye diseases: the Singapore Indian Eye Study.","volume":"120","author":"Pan","year":"2013","journal-title":"Ophthalmology"},{"issue":"1","key":"eoi250004r5","doi-asserted-by":"publisher","first-page":"2102","DOI":"10.1038\/s41467-021-22041-2","article-title":"Aberrant TGF-\u00df1 signaling activation by MAF underlies pathological lens growth in high myopia.","volume":"12","author":"Zhu","year":"2021","journal-title":"Nat Commun"},{"key":"eoi250004r6","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.ajo.2021.08.017","article-title":"Clinically significant intraocular lens decentration and tilt in highly myopic eyes: a swept-source optical coherence tomography study.","volume":"235","author":"Wang","year":"2022","journal-title":"Am J Ophthalmol"},{"key":"eoi250004r7","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1016\/j.ajo.2020.02.023","article-title":"Effect of axial length adjustment methods on intraocular lens power calculation in highly myopic eyes.","volume":"214","author":"Zhang","year":"2020","journal-title":"Am J Ophthalmol"},{"issue":"3","key":"eoi250004r8","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1016\/j.ajo.2012.08.019","article-title":"Capsular adhesion to intraocular lens in highly myopic eyes evaluated in vivo using ultralong-scan-depth optical coherence tomography.","volume":"155","author":"Zhao","year":"2013","journal-title":"Am J Ophthalmol"},{"issue":"11","key":"eoi250004r9","doi-asserted-by":"publisher","first-page":"1473","DOI":"10.1097\/j.jcrs.0000000000000664","article-title":"Efficacy and complications of cataract surgery in high myopia.","volume":"47","author":"Yao","year":"2021","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"eoi250004r10","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1038\/eye.2013.95","article-title":"Late in-the-bag intraocular lens dislocation requiring explantation: risk factors and outcomes.","volume":"27","author":"Fern\u00e1ndez-Buenaga","year":"2013","journal-title":"Eye (Lond)"},{"issue":"6","key":"eoi250004r11","doi-asserted-by":"publisher","first-page":"358","DOI":"10.3928\/1542-8877-19910601-16","article-title":"\u201cEquator ring\u201d for maintenance of the completely circular contour of the capsular bag equator after cataract removal.","volume":"22","author":"Hara","year":"1991","journal-title":"Ophthalmic Surg"},{"issue":"3","key":"eoi250004r12","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/S0886-3350(13)80126-5","article-title":"Endocapsular ring approach to the subluxed cataractous lens.","volume":"21","author":"Cionni","year":"1995","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"eoi250004r13","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1001\/jamaophthalmol.2024.2215","article-title":"Capsular tension ring implantation for intraocular lens decentration and tilt in highly myopic eyes: a randomized clinical trial.","volume":"142","author":"Lin","year":"2024","journal-title":"JAMA Ophthalmol"},{"issue":"8","key":"eoi250004r14","doi-asserted-by":"publisher","first-page":"1318","DOI":"10.1016\/j.jcrs.2008.04.034","article-title":"Efficacy and safety of capsular bending ring implantation to prevent posterior capsule opacification: three-year results of a randomized clinical trial.","volume":"34","author":"Menapace","year":"2008","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"eoi250004r15","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1186\/s12886-020-01772-8","article-title":"Effect of capsular tension ring implantation on capsular stability after phacoemulsification in patients with weak zonules: a randomized controlled trial. CTR implantation in cataract patients with weak zonules.","volume":"21","author":"Yang","year":"2021","journal-title":"BMC Ophthalmol"},{"issue":"11","key":"eoi250004r16","first-page":"979","article-title":"[Impact of capsular tension ring implantation in cataract patients with high myopia].","volume":"58","author":"Lin","year":"2022","journal-title":"Zhonghua Yan Ke Za Zhi"},{"issue":"1","key":"eoi250004r17","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/j.mjafi.2012.08.029","article-title":"A study to evaluate whether CTR increases refractive unpredictability between predicted and actual IOL position.","volume":"70","author":"Baranwal","year":"2014","journal-title":"Med J Armed Forces India"},{"key":"eoi250004r18","doi-asserted-by":"publisher","DOI":"10.1080\/08820538.2024.2381770","article-title":"Effect of implanted capsular tension ring on postoperative refractive shift: a systematic review and meta-analysis.","author":"Xu","journal-title":"Semin Ophthalmol"},{"issue":"3","key":"eoi250004r19","doi-asserted-by":"publisher","first-page":"174","DOI":"10.3928\/1081597X-20201229-01","article-title":"Effect of capsular tension ring on refractive outcomes in patients with implantation of the quadrifocal Acrysof PanOptix TFNT00 IOL.","volume":"37","author":"Kwon","year":"2021","journal-title":"J Refract Surg"},{"issue":"1","key":"eoi250004r20","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1186\/s40001-024-01726-6","article-title":"Effect of capsular tension ring on the refractive outcomes of patients with extreme high axial myopia after phacoemulsification.","volume":"29","author":"Zhao","year":"2024","journal-title":"Eur J Med Res"},{"issue":"12","key":"eoi250004r21","doi-asserted-by":"publisher","first-page":"2087","DOI":"10.1016\/j.jcrs.2010.06.065","article-title":"Effect of a capsular tension ring on refractive outcomes in eyes with high myopia.","volume":"36","author":"Schild","year":"2010","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"eoi250004r22","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.ophtha.2017.08.027","article-title":"Accuracy of intraocular lens calculation formulas.","volume":"125","author":"Melles","year":"2018","journal-title":"Ophthalmology"},{"issue":"4","key":"eoi250004r23","doi-asserted-by":"publisher","first-page":"259","DOI":"10.3928\/1081597X-20120309-01","article-title":"Intraocular lens tilt and decentration measured by Scheimpflug camera following manual or femtosecond laser-created continuous circular capsulotomy.","volume":"28","author":"Kr\u00e1nitz","year":"2012","journal-title":"J Refract Surg"},{"issue":"6","key":"eoi250004r24","doi-asserted-by":"publisher","first-page":"745","DOI":"10.1016\/j.jcrs.2018.04.035","article-title":"Astigmatism induced by intraocular lens tilt evaluated via ray tracing.","volume":"44","author":"Weikert","year":"2018","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"eoi250004r25","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1016\/j.ophtha.2013.09.049","article-title":"Effect of centration and circularity of manual capsulorrhexis on cataract surgery refractive outcomes.","volume":"121","author":"Okada","year":"2014","journal-title":"Ophthalmology"},{"issue":"6","key":"eoi250004r26","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1016\/S0886-3350(00)00318-7","article-title":"Complications of endocapsular tension ring implantation in a child with Marfan\u2019s syndrome.","volume":"26","author":"Dietlein","year":"2000","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"eoi250004r27","doi-asserted-by":"publisher","first-page":"158","DOI":"10.5935\/0004-2749.20210024","article-title":"Optimal timing of capsular tension ring implantation in pseudoexfoliation syndrome.","volume":"84","author":"Ozturk","year":"2021","journal-title":"Arq Bras Oftalmol"}],"container-title":["JAMA Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/jamanetwork.com\/journals\/jamaophthalmology\/articlepdf\/2831676\/jamaophthalmology_lin_2025_oi_250004_1746666020.73148.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,15]],"date-time":"2025-05-15T15:01:34Z","timestamp":1747321294000},"score":1,"resource":{"primary":{"URL":"https:\/\/jamanetwork.com\/journals\/jamaophthalmology\/fullarticle\/2831676"}},"subtitle":["Secondary Analysis of a Randomized Clinical Trial"],"short-title":[],"issued":{"date-parts":[[2025,5,1]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,5,1]]}},"URL":"https:\/\/doi.org\/10.1001\/jamaophthalmol.2025.0110","relation":{},"ISSN":["2168-6165"],"issn-type":[{"value":"2168-6165","type":"print"}],"subject":[],"published":{"date-parts":[[2025,5,1]]}}}