{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T22:12:46Z","timestamp":1794867166779,"version":"4.9.1"},"reference-count":54,"publisher":"American Medical Association (AMA)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JAMA Ophthalmol"],"published-print":{"date-parts":[[2025,8,1]]},"abstract":"<jats:sec id=\"ab-eoi250028-4\"><jats:title>Importance<\/jats:title><jats:p>There is currently no consensus regarding the association of capsular tension ring (CTR) on intraocular lens (IOL) position or the indications for its implantation.<\/jats:p><\/jats:sec><jats:sec id=\"ab-eoi250028-5\"><jats:title>Objective<\/jats:title><jats:p>To evaluate the association of CTR implantation on IOL position.<\/jats:p><\/jats:sec><jats:sec id=\"ab-eoi250028-6\"><jats:title>Data Sources<\/jats:title><jats:p>PubMed, Embase, and Cochrane Library were searched from their inception to October 18, 2024.<\/jats:p><\/jats:sec><jats:sec id=\"ab-eoi250028-7\"><jats:title>Study Selection<\/jats:title><jats:p>Randomized clinical trials (RCTs) or prospective cohorts reporting the effect or association of CTR on postoperative anterior chamber depth (ACD), IOL decentration, tilt, or rotation.<\/jats:p><\/jats:sec><jats:sec id=\"ab-eoi250028-8\"><jats:title>Data Extraction and Synthesis<\/jats:title><jats:p>Data extraction was conducted by 2 reviewers and verified by another for accuracy. Mean difference (MD) was used to synthesize the effect measures, and subgroup analyses were conducted according to IOL haptic design (C-loop and plate haptic) and whether the patient had high myopia.<\/jats:p><\/jats:sec><jats:sec id=\"ab-eoi250028-9\"><jats:title>Main Outcome and Measures<\/jats:title><jats:p>Postoperative ACD and IOL decentration, tilt, and rotation.<\/jats:p><\/jats:sec><jats:sec id=\"ab-eoi250028-10\"><jats:title>Results<\/jats:title><jats:p>A total of 11 RCTs and 7 cohort studies, involving 809 eyes with CTR and 822 eyes without CTR, were included in this meta-analysis. The analysis revealed that IOL tilt (MD, \u22121.04\u00b0; 95% CI, \u22122.05\u00b0 to \u22120.03\u00b0; <jats:italic>P<\/jats:italic>\u2009=\u2009.04) and rotation (MD, \u22120.82\u00b0; 95% CI, \u22121.27\u00b0 to \u22120.37\u00b0; <jats:italic>P<\/jats:italic>\u2009&amp;amp;lt;\u2009.001) were smaller in the CTR group compared with the control group. The subgroup analysis of ACD (<jats:italic>I<jats:sup>2<\/jats:sup><\/jats:italic>\u2009=\u200970.7%; <jats:italic>P<\/jats:italic>\u2009=\u2009.03), decentration (<jats:italic>I<jats:sup>2<\/jats:sup><\/jats:italic>\u2009=\u200966.5%, <jats:italic>P<\/jats:italic>\u2009=\u2009.08), and tilt (<jats:italic>I<jats:sup>2<\/jats:sup><\/jats:italic>\u2009=\u200976.7%, <jats:italic>P<\/jats:italic>\u2009=\u2009.01) revealed a heterogeneity between the subgroups stratified according to IOL haptic design. Additionally, subgroup analysis demonstrated that CTR group showed a deeper ACD in eyes implanted with plate haptic IOLs (MD, 0.11 mm; 95% CI, 0.02 to 0.20 mm; <jats:italic>P<\/jats:italic>\u2009=\u2009.01), and a smaller IOL tilt in highly myopic eyes (MD, \u22121.43\u00b0; 95% CI, \u22122.59\u00b0 to \u22120.26\u00b0; <jats:italic>P<\/jats:italic>\u2009=\u2009.02) compared with the control group.<\/jats:p><\/jats:sec><jats:sec id=\"ab-eoi250028-11\"><jats:title>Conclusions and Relevance<\/jats:title><jats:p>CTR implantation was associated with enhanced stability of IOL rotation in this meta-analysis, while only reducing IOL tilt in high myopia. While the direct clinical relevance of these results could not be determined from this investigation, these findings provide evidence supporting use of CTR implantation when toric IOLs have been implanted or with high myopia, although a hyperopic refractive shift after implantation of plate haptic IOLs may require target refraction adjustment.<\/jats:p><\/jats:sec>","DOI":"10.1001\/jamaophthalmol.2025.1623","type":"journal-article","created":{"date-parts":[[2025,6,12]],"date-time":"2025-06-12T11:01:06Z","timestamp":1749726066000},"page":"643","source":"Crossref","is-referenced-by-count":6,"title":["Capsular Tension Ring Implantation for Intraocular Lens Position"],"prefix":"10.1001","volume":"143","author":[{"given":"Haowen","family":"Lin","sequence":"first","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Zhang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaohang","family":"Xie","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuhua","family":"Tan","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"Jin","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiaqing","family":"Zhang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lixia","family":"Luo","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yizhi","family":"Liu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10","reference":[{"issue":"3","key":"eoi250028r1","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1136\/bjophthalmol-2020-317822","article-title":"Anterior chamber depth, lens thickness and intraocular lens calculation formula accuracy: nine formulas comparison.","volume":"106","author":"Hip\u00f3lito-Fernandes","year":"2022","journal-title":"Br J Ophthalmol"},{"issue":"3","key":"eoi250028r2","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1016\/j.jcrs.2018.01.015","article-title":"Accuracy of 8 intraocular lens calculation formulas in relation to anterior chamber depth in patients with normal axial lengths.","volume":"44","author":"G\u00f6kce","year":"2018","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"eoi250028r3","doi-asserted-by":"publisher","first-page":"1724","DOI":"10.1016\/j.ophtha.2011.02.025","article-title":"The influence of tilt, decentration, and pupil size on the higher-order aberration profile of aspheric intraocular lenses.","volume":"118","author":"McKelvie","year":"2011","journal-title":"Ophthalmology"},{"issue":"5","key":"eoi250028r4","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1016\/j.jcrs.2018.10.049","article-title":"Effects of decentration and tilt on the optical performance of 6 aspheric intraocular lens designs in a model eye [published correction in J Cataract Refract Surg. 2019;45(5):708].","volume":"45","author":"Lawu","year":"2019","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"eoi250028r5","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1016\/j.jcrs.2012.01.029","article-title":"Visual simulation through different intraocular lenses using adaptive optics: effect of tilt and decentration.","volume":"38","author":"Madrid-Costa","year":"2012","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"eoi250028r6","doi-asserted-by":"publisher","first-page":"1654","DOI":"10.1016\/j.jcrs.2014.01.044","article-title":"Long-term clinical outcomes of toric intraocular lens implantation in cataract cases with preexisting astigmatism.","volume":"40","author":"Miyake","year":"2014","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"eoi250028r7","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1016\/j.ophtha.2023.10.010","article-title":"Toric monofocal intraocular lenses for the correction of astigmatism during cataract surgery: a report by the American Academy of Ophthalmology.","volume":"131","author":"Al-Mohtaseb","year":"2024","journal-title":"Ophthalmology"},{"key":"eoi250028r8","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.ajo.2021.08.017","article-title":"Clinically significant intraocular lens decentration and tilt in highly myopic eyes: a swept-source optical coherence tomography study.","volume":"235","author":"Wang","year":"2022","journal-title":"Am J Ophthalmol"},{"issue":"11","key":"eoi250028r9","doi-asserted-by":"publisher","first-page":"1318","DOI":"10.1097\/j.jcrs.0000000000000997","article-title":"Predicting the risk of clinically significant intraocular lens tilt and decentration in vitrectomized eyes.","volume":"48","author":"Zhang","year":"2022","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"eoi250028r10","doi-asserted-by":"publisher","first-page":"358","DOI":"10.3928\/1542-8877-19910601-16","article-title":"\u201cEquator ring\u201d for maintenance of the completely circular contour of the capsular bag equator after cataract removal.","volume":"22","author":"Hara","year":"1991","journal-title":"Ophthalmic Surg"},{"issue":"3","key":"eoi250028r11","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/S0886-3350(13)80126-5","article-title":"Endocapsular ring approach to the subluxed cataractous lens.","volume":"21","author":"Cionni","year":"1995","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"eoi250028r12","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1016\/j.ophtha.2004.09.022","article-title":"Interim results of the United States investigational device study of the Ophtec capsular tension ring.","volume":"112","author":"Price","year":"2005","journal-title":"Ophthalmology"},{"issue":"8","key":"eoi250028r13","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1001\/jamaophthalmol.2024.2215","article-title":"Capsular tension ring implantation for intraocular lens decentration and tilt in highly myopic eyes: a randomized clinical trial.","volume":"142","author":"Lin","year":"2024","journal-title":"JAMA Ophthalmol"},{"issue":"4","key":"eoi250028r14","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1016\/j.ophtha.2023.10.031","article-title":"Influence of a capsular tension ring on capsular bag behavior of a plate haptic intraocular lens: an intraindividual randomized trial.","volume":"131","author":"Schartm\u00fcller","year":"2024","journal-title":"Ophthalmology"},{"issue":"1","key":"eoi250028r15","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/j.mjafi.2012.08.029","article-title":"A study to evaluate whether CTR increases refractive unpredictability between predicted and actual IOL position.","volume":"70","author":"Baranwal","year":"2014","journal-title":"Med J Armed Forces India"},{"issue":"5","key":"eoi250028r16","doi-asserted-by":"publisher","first-page":"1236","DOI":"10.3349\/ymj.2016.57.5.1236","article-title":"Effect of co-implantation of a capsular tension ring on clinical outcomes after cataract surgery with monofocal intraocular lens implantation.","volume":"57","author":"Park","year":"2016","journal-title":"Yonsei Med J"},{"issue":"71","key":"eoi250028r17","doi-asserted-by":"publisher","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews.","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"eoi250028r18","doi-asserted-by":"publisher","first-page":"l4898","DOI":"10.1136\/bmj.l4898","article-title":"RoB 2: a revised tool for assessing risk of bias in randomised trials.","volume":"366","author":"Sterne","year":"2019","journal-title":"BMJ"},{"issue":"4","key":"eoi250028r19","doi-asserted-by":"publisher","first-page":"e485","DOI":"10.1111\/aos.15793","article-title":"Differences in the prevalence of uveitis between Crohn\u2019s disease and ulcerative colitis: a systematic review and meta-analysis.","volume":"102","author":"Lin","year":"2024","journal-title":"Acta Ophthalmol"},{"issue":"9","key":"eoi250028r20","doi-asserted-by":"publisher","first-page":"e654","DOI":"10.3928\/1081597X-20240723-02","article-title":"Influence of capsular tension rings on the IOL-capsule complex in patients with long axial length: a clinical observation based on SS-OCT.","volume":"40","author":"Chang","year":"2024","journal-title":"J Refract Surg"},{"issue":"1","key":"eoi250028r21","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1186\/s12886-019-1147-5","article-title":"Rotation of a toric intraocular lens with and without capsular tension ring: data from a multicenter non-inferiority randomized clinical trial (RCT).","volume":"19","author":"Hahn","year":"2019","journal-title":"BMC Ophthalmol"},{"issue":"10","key":"eoi250028r22","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.1097\/j.jcrs.0000000000001495","article-title":"Effectiveness of prophylactic capsular tension ring implantation during cataract surgery in highly myopic eyes.","volume":"50","author":"Hu","year":"2024","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"eoi250028r23","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1016\/j.jcrs.2004.04.063","article-title":"Change in IOL position and capsular bag size with an angulated intraocular lens early after cataract surgery.","volume":"31","author":"Koeppl","year":"2005","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"eoi250028r24","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1016\/S0886-3350(01)01174-9","article-title":"Effect of a capsular tension ring on intraocular lens decentration and tilting after cataract surgery.","volume":"28","author":"Lee","year":"2002","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"eoi250028r25","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1186\/s12886-024-03602-7","article-title":"Effect of capsular tension ring implantation on intraocular lens calculation formula selection for long axial myopia.","volume":"24","author":"Liang","year":"2024","journal-title":"BMC Ophthalmol"},{"issue":"1","key":"eoi250028r26","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1097\/j.jcrs.0000000000001554","article-title":"Rotational stability of plate-haptic toric intraocular lenses implantation with a capsular tension ring: prospective randomized paired-eye study.","volume":"51","author":"Lin","year":"2025","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"eoi250028r27","doi-asserted-by":"publisher","first-page":"989","DOI":"10.1007\/s00417-022-05851-y","article-title":"Propensity-matched comparison of postoperative stability and visual outcomes of toric intraocular lens with or without a capsular tension ring and updated meta-analysis.","volume":"261","author":"Ma","year":"2023","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"1","key":"eoi250028r28","first-page":"113","article-title":"Application effect of capsular tension ring in patients with high myopia, cataract and suspensory ligament relaxation.","volume":"23","author":"Meng","year":"2023","journal-title":"Intl Eye Sci"},{"issue":"3","key":"eoi250028r29","doi-asserted-by":"publisher","first-page":"411","DOI":"10.4103\/ijo.IJO_875_17","article-title":"Comparative evaluation of rotational stability and visual outcome of toric intraocular lenses with and without a capsular tension ring.","volume":"66","author":"Rastogi","year":"2018","journal-title":"Indian J Ophthalmol"},{"issue":"4","key":"eoi250028r30","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1097\/j.jcrs.0000000000001111","article-title":"Clinical and laboratory studies on the effects of capsular tension ring on surgical outcomes of trifocal intraocular lens implantation.","volume":"49","author":"Sugita","year":"2023","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"eoi250028r31","doi-asserted-by":"publisher","first-page":"186","DOI":"10.3928\/1081597X-20200120-01","article-title":"Effect of capsular tension ring implantation on postoperative rotational stability of a toric intraocular lens.","volume":"36","author":"Vokrojov\u00e1","year":"2020","journal-title":"J Refract Surg"},{"issue":"2","key":"eoi250028r32","first-page":"114","article-title":"Application of capsular tension ring implantation during phacoemulsification for ultra-high myopia complicated with cataract.","volume":"38","author":"Wang","year":"2020","journal-title":"Chin J Exp Ophthalmol"},{"issue":"1","key":"eoi250028r33","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.jcrs.2014.04.035","article-title":"Effect of a capsular tension ring on axial intraocular lens position.","volume":"41","author":"Weber","year":"2015","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"eoi250028r34","first-page":"1274","article-title":"Postoperative changes of anterior chamber depth and lens suspensory ligament in patients with ultra-high myopia and cataract and related influencing factors.","volume":"23","author":"Xiong","year":"2023","journal-title":"Intl Eye Sci"},{"issue":"12","key":"eoi250028r35","doi-asserted-by":"publisher","first-page":"2474","DOI":"10.1016\/j.ophtha.2016.09.005","article-title":"Prediction of postoperative intraocular lens position with angle-to-angle depth using anterior segment optical coherence tomography.","volume":"123","author":"Goto","year":"2016","journal-title":"Ophthalmology"},{"issue":"1","key":"eoi250028r36","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/S0002-9394(14)71745-3","article-title":"Refractive power calculations for intraocular lenses in the phakic eye.","volume":"116","author":"Holladay","year":"1993","journal-title":"Am J Ophthalmol"},{"issue":"11","key":"eoi250028r37","doi-asserted-by":"publisher","first-page":"2069","DOI":"10.1016\/S0886-3350(03)00257-8","article-title":"Accommodation obtained per 1.0 mm forward movement of a posterior chamber intraocular lens.","volume":"29","author":"Nawa","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"eoi250028r38","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2022.106868","article-title":"Predicting the biomechanical stability of IOLs inside the postcataract capsular bag with a finite element model.","volume":"221","author":"Cabeza-Gil","year":"2022","journal-title":"Comput Methods Programs Biomed"},{"issue":"9","key":"eoi250028r39","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.1016\/S0886-3350(96)80070-8","article-title":"Experimental study of different intraocular lens designs implanted in the bag after capsulorhexis.","volume":"22","author":"Ta\u00f1\u00e1","year":"1996","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"eoi250028r40","doi-asserted-by":"publisher","first-page":"846","DOI":"10.1016\/j.jcrs.2006.02.009","article-title":"Anatomic evaluation of the Morcher capsular tension ring by ultrasound biomicroscopy.","volume":"32","author":"Boomer","year":"2006","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"eoi250028r41","doi-asserted-by":"publisher","first-page":"2158","DOI":"10.1016\/j.jcrs.2004.02.072","article-title":"Influence of intraocular lens tilt and decentration on wavefront aberrations.","volume":"30","author":"Taketani","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"eoi250028r42","doi-asserted-by":"publisher","first-page":"2415","DOI":"10.2147\/OPTH.S72053","article-title":"Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye.","volume":"8","author":"Fujikado","year":"2014","journal-title":"Clin Ophthalmol"},{"issue":"11","key":"eoi250028r43","first-page":"979","article-title":"Impact of capsular tension ring implantation in cataract patients with high myopia [in Chinese].","volume":"58","author":"Lin","year":"2022","journal-title":"Zhonghua Yan Ke Za Zhi"},{"issue":"1","key":"eoi250028r44","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1186\/s12886-020-01772-8","article-title":"Effect of capsular tension ring implantation on capsular stability after phacoemulsification in patients with weak zonules: a randomized controlled trial: CTR implantation in cataract patients with weak zonules.","volume":"21","author":"Yang","year":"2021","journal-title":"BMC Ophthalmol"},{"issue":"10","key":"eoi250028r45","doi-asserted-by":"publisher","first-page":"1631","DOI":"10.1016\/j.jcrs.2008.04.041","article-title":"Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation.","volume":"34","author":"Ma","year":"2008","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"eoi250028r46","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1016\/j.jcrs.2013.02.020","article-title":"Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications.","volume":"39","author":"Visser","year":"2013","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"eoi250028r47","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.jcrs.2010.08.049","article-title":"Rotational stability and posterior capsule opacification of a plate-haptic and an open-loop-haptic intraocular lens.","volume":"37","author":"Prinz","year":"2011","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"eoi250028r48","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.jcrs.2011.08.028","article-title":"Rotational stability of a toric intraocular lens: influence of axial length and alignment in the capsular bag.","volume":"38","author":"Shah","year":"2012","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"eoi250028r49","doi-asserted-by":"publisher","first-page":"252","DOI":"10.3928\/1081597X-20130318-04","article-title":"Clinical and optical intraocular performance of rotationally asymmetric multifocal IOL plate-haptic design versus C-loop haptic design.","volume":"29","author":"Ali\u00f3","year":"2013","journal-title":"J Refract Surg"},{"issue":"10","key":"eoi250028r50","doi-asserted-by":"publisher","first-page":"1353","DOI":"10.1097\/j.jcrs.0000000000000259","article-title":"Comparison of the rotational stability between plate-haptic toric and C-loop haptic toric IOLs in myopic eyes.","volume":"46","author":"Zhu","year":"2020","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"eoi250028r51","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1080\/08820538.2016.1247181","article-title":"Combined special capsular tension ring and toric IOL implantation for management of astigmatism and high axial myopia with cataracts.","volume":"33","author":"Zhao","year":"2018","journal-title":"Semin Ophthalmol"},{"issue":"3","key":"eoi250028r52","doi-asserted-by":"publisher","first-page":"378","DOI":"10.18240\/ijo.2021.03.07","article-title":"Comparative evaluation of rotational stability of toric IOLs with four-eyelet vs two-eyelet capsular tension rings in eyes with high myopia.","volume":"14","author":"Jiang","year":"2021","journal-title":"Int J Ophthalmol"},{"issue":"1","key":"eoi250028r53","doi-asserted-by":"publisher","first-page":"2102","DOI":"10.1038\/s41467-021-22041-2","article-title":"Aberrant TGF-\u00df1 signaling activation by MAF underlies pathological lens growth in high myopia [published correction appears in Nat Commun. 2022 Dec 20;13(1):7834].","volume":"12","author":"Zhu","year":"2021","journal-title":"Nat Commun"},{"issue":"11","key":"eoi250028r54","doi-asserted-by":"publisher","first-page":"1436","DOI":"10.1097\/j.jcrs.0000000000000653","article-title":"Associations between anterior segment parameters and rotational stability of a plate-haptic toric intraocular lens.","volume":"47","author":"Yao","year":"2021","journal-title":"J Cataract Refract Surg"}],"container-title":["JAMA Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/jamanetwork.com\/journals\/jamaophthalmology\/articlepdf\/2835223\/jamaophthalmology_lin_2025_oi_250028_1754685063.66042.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,21]],"date-time":"2025-08-21T15:00:40Z","timestamp":1755788440000},"score":1,"resource":{"primary":{"URL":"https:\/\/jamanetwork.com\/journals\/jamaophthalmology\/fullarticle\/2835223"}},"subtitle":["A Systematic Review and Meta-Analysis"],"short-title":[],"issued":{"date-parts":[[2025,8,1]]},"references-count":54,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2025,8,1]]}},"URL":"https:\/\/doi.org\/10.1001\/jamaophthalmol.2025.1623","relation":{},"ISSN":["2168-6165"],"issn-type":[{"value":"2168-6165","type":"print"}],"subject":[],"published":{"date-parts":[[2025,8,1]]}}}