{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T10:20:40Z","timestamp":1768558840477,"version":"3.49.0"},"reference-count":28,"publisher":"American Medical Association (AMA)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JAMA Ophthalmol"],"published-print":{"date-parts":[[2026,1,1]]},"abstract":"<jats:sec>\n                    <jats:title>Importance<\/jats:title>\n                    <jats:p>Appropriately sized and well-centered capsulorhexis is key for high-quality phacoemulsification cataract surgery and can be achieved with digital-guidance devices. However, such devices are not readily available, warranting the need for a device-free manual auxiliary capsulorhexis technique.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>To determine if manual marking\u2013assisted capsulorhexis (MMAC) is noninferior to a digital guidance\u2013assisted capsulorhexis (DGAC) in capsulorhexis accuracy following phacoemulsification for age-related cataract.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design, Setting, and Participants<\/jats:title>\n                    <jats:p>This noninferiority randomized clinical trial was conducted between July 2021 and December 2021 at Zhongshan Ophthalmic Center, China, with follow-up through 1 month after surgery. Of 204 adults screened, 156 were included who were aged 55 to 80 years and had pupil diameter \u22656.5 mm after pupil dilation and Lens Opacities Classification System III with nuclear opalescence grade of 3.0 to 4.0. Patients were excluded if they had previous intraocular surgery or a diagnosed eye disease that might affect functions of lens suspensory ligament. Data were analyzed from September to December 2024.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interventions<\/jats:title>\n                    <jats:p>In the MMAC group, a lens caliper was used to measure and locate capsulorhexis position, subsequently applying its blunt head to mark the anterior lens capsule for capsulotomy guidance. In the DGAC group, a ring with predefined target diameter was projected to guide capsulorhexis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main Outcomes and Measures<\/jats:title>\n                    <jats:p>The primary outcome was the median deviation of capsulorhexis diameter from the target diameter with a noninferiority margin of 0.2 mm. Secondary outcomes included ratio of ideal capsulorhexis, grades of capsulorhexis\u2013intraocular lens (IOL) overlap, off-center distance of capsulorhexis, postoperative best-corrected visual acuity, IOL tilt, and decentration.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Among 156 participants randomized into the MMAC group (mean [SD] age, 71 [7] years; 47 [60%] female) or DGAC group (mean [SD] age, 72 [7]; 47 [60%] female), median deviations comparing the capsulorhexis and target diameters were 0.22 mm (95% CI, 0.11-0.37) in the MMAC group vs 0.27 mm (95% CI, 0.14-0.52) in the DGAC group (difference, \u22120.05 mm; 95% CI, \u22120.16 to 0.07) for horizontal diameter and 0.27 mm (95% CI, 0.12-0.40) vs 0.33 mm (95% CI, 0.20-0.51) (difference, \u22120.06 mm; 95% CI, \u22120.17 to 0.05), respectively, for vertical diameters, both within the noninferiority margin of 0.20 mm. The proportion of ideal capsulorhexis was 96.2% (75 of 78) in the MMAC group and 88.5% (69 of 78) in the DGAC group (difference, 7.7%; 95% CI, \u22120.6 to 16.0), also within the noninferiority margin of \u22125.0%.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions and Relevance<\/jats:title>\n                    <jats:p>The findings in this trial indicate that accuracy of capsulorhexis with MMAC was noninferior to DGAC. Since the MMAC technique does not require special equipment, it might be considered routinely in clinical practice settings if similar outcomes are obtained elsewhere.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial Registration<\/jats:title>\n                    <jats:p>\n                      ClinicalTrials.gov Identifier:\n                      <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/clinicaltrials.gov\/study\/NCT04977115\">NCT04977115<\/jats:ext-link>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1001\/jamaophthalmol.2025.4448","type":"journal-article","created":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T16:00:39Z","timestamp":1763049639000},"page":"15","source":"Crossref","is-referenced-by-count":0,"title":["Manual Marking Guidance vs Digital Guidance System\u2013Assisted Capsulorhexis in Phacoemulsification"],"prefix":"10.1001","volume":"144","author":[{"given":"Xiaoyun","family":"Chen","sequence":"first","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zitian","family":"Liu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ling","family":"Jin","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yingfeng","family":"Zheng","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lixia","family":"Luo","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yizhi","family":"Liu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"10","reference":[{"issue":"10094","key":"eoi250070r1","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1016\/S0140-6736(17)30544-5","article-title":"Cataracts.","volume":"390","author":"Liu","year":"2017","journal-title":"Lancet"},{"issue":"1","key":"eoi250070r2","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1038\/sj.eye.6703015","article-title":"The Cataract National Dataset electronic multi-centre audit of 55,567 operations: updating benchmark standards of care in the United Kingdom and internationally.","volume":"23","author":"Jaycock","year":"2009","journal-title":"Eye (Lond)"},{"issue":"4","key":"eoi250070r3","doi-asserted-by":"crossref","first-page":"450","DOI":"10.4103\/ijo.IJO_1728_18","article-title":"Techniques of anterior capsulotomy in cataract surgery.","volume":"67","author":"Sharma","year":"2019","journal-title":"Indian J Ophthalmol"},{"issue":"3","key":"eoi250070r4","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/S0002-9394(99)00157-9","article-title":"The effect of capsulorhexis size on posterior capsular opacification: one-year results of a randomized prospective trial.","volume":"128","author":"Hollick","year":"1999","journal-title":"Am J Ophthalmol"},{"issue":"3","key":"eoi250070r5","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1016\/j.ophtha.2013.09.049","article-title":"Effect of centration and circularity of manual capsulorrhexis on cataract surgery refractive outcomes.","volume":"121","author":"Okada","year":"2014","journal-title":"Ophthalmology"},{"issue":"6","key":"eoi250070r6","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1177\/112067210301300606","article-title":"The effect of capsulorhexis size on development of posterior capsule opacification: small (4.5 to 5.0 mm) versus large (6.0 to 7.0 mm).","volume":"13","author":"Aykan","year":"2003","journal-title":"Eur J Ophthalmol"},{"issue":"8","key":"eoi250070r7","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.1097\/j.jcrs.0000000000000219","article-title":"Characteristics and factors associated with intraocular lens tilt and decentration after cataract surgery.","volume":"46","author":"Chen","year":"2020","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"eoi250070r8","doi-asserted-by":"crossref","first-page":"185","DOI":"10.3928\/1542-8877-19990301-06","article-title":"The relationship between capsulorhexis size and anterior chamber depth relation.","volume":"30","author":"Ceki\u00e7","year":"1999","journal-title":"Ophthalmic Surg Lasers"},{"key":"eoi250070r9","doi-asserted-by":"crossref","first-page":"16227","DOI":"10.1038\/srep16227","article-title":"Capsular outcomes differ with capsulorhexis sizes after pediatric cataract surgery: a randomized controlled trial.","volume":"5","author":"Lin","year":"2015","journal-title":"Sci Rep"},{"issue":"5","key":"eoi250070r10","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1016\/S0886-3350(96)80014-9","article-title":"Capsular opening contraction after continuous curvilinear capsulorhexis and intraocular lens implantation.","volume":"22","author":"Joo","year":"1996","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"eoi250070r11","doi-asserted-by":"crossref","first-page":"35","DOI":"10.3390\/medicina57010035","article-title":"Anterior capsule opening contraction and late intraocular lens dislocation after cataract surgery in patients with weak or partially absent zonular support.","volume":"57","author":"Vanags","year":"2021","journal-title":"Medicina (Kaunas)"},{"issue":"11","key":"eoi250070r12","doi-asserted-by":"crossref","first-page":"3803","DOI":"10.4103\/ijo.IJO_1812_22","article-title":"Complications of manual small-incision cataract surgery.","volume":"70","author":"Goel","year":"2022","journal-title":"Indian J Ophthalmol"},{"issue":"3","key":"eoi250070r13","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1038\/s41433-019-0521-0","article-title":"Early postoperative rotational stability and its related factors of a single-piece acrylic toric intraocular lens.","volume":"34","author":"Li","year":"2020","journal-title":"Eye (Lond)"},{"issue":"1","key":"eoi250070r14","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1186\/s12886-020-01465-2","article-title":"Early-stage clinical outcomes and rotational stability of TECNIS toric intraocular lens implantation in cataract cases with long axial length.","volume":"20","author":"He","year":"2020","journal-title":"BMC Ophthalmol"},{"issue":"3","key":"eoi250070r15","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1016\/j.jcrs.2016.12.027","article-title":"Clinical performance in continuous curvilinear capsulorhexis creation supported by a digital image guidance system.","volume":"43","author":"Haeussler-Sinangin","year":"2017","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"eoi250070r16","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1016\/j.jcrs.2008.03.025","article-title":"New technology for sizing the continuous curvilinear capsulorhexis: prospective trial.","volume":"34","author":"Dick","year":"2008","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"eoi250070r17","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1272\/jnms.79.195","article-title":"Usefulness of a semicircular capsulotomy marker.","volume":"79","author":"Suzuki","year":"2012","journal-title":"J Nippon Med Sch"},{"issue":"8","key":"eoi250070r18","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1016\/j.jcrs.2006.02.067","article-title":"Ring-shaped caliper for better anterior capsulorhexis sizing and centration.","volume":"32","author":"Tassignon","year":"2006","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"eoi250070r19","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1016\/j.jcrs.2013.10.041","article-title":"New device for creating a continuous curvilinear capsulorhexis.","volume":"40","author":"Powers","year":"2014","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"eoi250070r20","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1016\/j.jcrs.2015.06.004","article-title":"Open ring-shaped guider for circular continuous curvilinear capsulorhexis during cataract surgery.","volume":"41","author":"Lee","year":"2015","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"eoi250070r21","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/ICU.0000000000000539","article-title":"Advances in capsulorhexis.","volume":"30","author":"Hu","year":"2019","journal-title":"Curr Opin Ophthalmol"},{"issue":"10","key":"eoi250070r22","doi-asserted-by":"crossref","first-page":"654","DOI":"10.3928\/1081597X-20160609-02","article-title":"Continuous curvilinear capsulorhexis performed with the VERUS ophthalmic caliper.","volume":"32","author":"Kahook","year":"2016","journal-title":"J Refract Surg"},{"issue":"20","key":"eoi250070r23","doi-asserted-by":"crossref","first-page":"2191","DOI":"10.1001\/jama.2013.281053","article-title":"World Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects.","volume":"310","author":"World Medical Association","year":"2013","journal-title":"JAMA"},{"issue":"24","key":"eoi250070r24","doi-asserted-by":"crossref","first-page":"2594","DOI":"10.1001\/jama.2012.87802","article-title":"Reporting of noninferiority and equivalence randomized trials: extension of the CONSORT 2010 statement.","volume":"308","author":"Piaggio","year":"2012","journal-title":"JAMA"},{"issue":"1","key":"eoi250070r25","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1038\/s41746-025-01887-6","article-title":"Digitalization of surgical features improves surgical accuracy via surgeon guidance and robotization.","volume":"8","author":"Chen","year":"2025","journal-title":"NPJ Digit Med"},{"issue":"1","key":"eoi250070r26","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/s12886-023-02776-w","article-title":"Multiple linear regression model for improving accuracy of capsulorhexis size calculation in femtosecond laser-assisted cataract surgery for adults: a retrospective single-center study.","volume":"23","author":"Akaishi","year":"2023","journal-title":"BMC Ophthalmol"},{"issue":"1","key":"eoi250070r27","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1186\/s40662-023-00347-0","article-title":"Safety and efficacy of cataract surgery performed with a low-energy femtosecond laser compared with conventional phacoemulsification in Chinese patients: a randomized clinical trial.","volume":"10","author":"Zhou","year":"2023","journal-title":"Eye Vis (Lond)"},{"issue":"8","key":"eoi250070r28","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1136\/bjophthalmol-2014-306065","article-title":"Defining the ideal femtosecond laser capsulotomy.","volume":"99","author":"Packer","year":"2015","journal-title":"Br J Ophthalmol"}],"container-title":["JAMA Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/jamanetwork.com\/journals\/jamaophthalmology\/articlepdf\/2841078\/jamaophthalmology_chen_2025_oi_250070_1767803516.2725.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T16:01:43Z","timestamp":1768492903000},"score":1,"resource":{"primary":{"URL":"https:\/\/jamanetwork.com\/journals\/jamaophthalmology\/fullarticle\/2841078"}},"subtitle":["A Noninferiority Randomized Clinical Trial"],"short-title":[],"issued":{"date-parts":[[2026,1,1]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1,1]]}},"URL":"https:\/\/doi.org\/10.1001\/jamaophthalmol.2025.4448","relation":{},"ISSN":["2168-6165"],"issn-type":[{"value":"2168-6165","type":"print"}],"subject":[],"published":{"date-parts":[[2026,1,1]]}}}