{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T19:50:09Z","timestamp":1793649009576,"version":"4.5.1"},"reference-count":37,"publisher":"American Medical Association (AMA)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JAMA Otolaryngol Head Neck Surg"],"published-print":{"date-parts":[[2023,6,1]]},"abstract":"<jats:sec>\n                    <jats:title>Importance<\/jats:title>\n                    <jats:p>Hearing loss is a highly prevalent condition, with numerous debilitating consequences when left untreated. However, less than 20% of US adults with hearing loss use hearing aids. Over-the-counter (OTC) hearing aids became available in October 2022 to improve access and affordability. However, clinical effectiveness studies of available OTC hearing aids using the existing devices in the market are limited.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To compare the clinical effectiveness of a self-fitting OTC hearing aid with remote support and a hearing aid fitted using audiologist-fitted best practices.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design, Setting, and Participants<\/jats:title>\n                    <jats:p>This randomized clinical effectiveness trial was conducted between April 14 and August 29, 2022. Sixty-eight adults with self-perceived mild to moderate hearing loss were recruited and randomly assigned to either the self-fitting or the audiologist-fitted group. Following bilateral hearing aid fitting, participants first completed a 2-week, take-home field trial without any support. Access to fine-tuning for both groups was only available after the 2-week trial. Support and adjustment were provided remotely for the self-fitting group per request and by the audiologist for the audiologist-fitted group. Participants were then reassessed after an additional 4-week take-home trial.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interventions<\/jats:title>\n                    <jats:p>A commercially available self-fitting OTC hearing aid was provided to participants in the self-fitting group who were expected to set up the hearing aids using the commercially supplied instructional material and accompanying smartphone application. In the audiologist-fitted group, audiologists fitted the same hearing aid according to the National Acoustics Laboratories nonlinear version 2 algorithm for prescriptive gain target using real-ear verification with hearing aid use instruction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main Outcomes and Measures<\/jats:title>\n                    <jats:p>The primary outcome measure was self-reported hearing aid benefit, measured using the Abbreviated Profile of Hearing Aid Benefit (APHAB). Secondary measures included the International Outcome Inventory for Hearing Aids (IOI-HA) and speech recognition in noise measured using an abbreviated speech-in-noise test and a digits-in-noise test. All measures were completed at baseline and at 2 intervals following hearing aid fitting (2 and 6 weeks).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Sixty-four participants were included in the analytic sample (33 men [51.6%]; mean [SD] age, 63.6 [14.1] years), with equal numbers of participants (n\u2009=\u200932) randomized into each group. The groups did not differ significantly in age (effect size\n                      <jats:italic>r<\/jats:italic>\n                      = \u22120.2 [95% CI, \u22120.3 to 0.2]) or 4-frequency pure-tone average (effect size\n                      <jats:italic>r<\/jats:italic>\n                      = 0.2 [95% CI, \u22120.1 to 0.4]). After the 2-week field trial, the self-fitting group had an initial advantage compared with the audiologist-fitted group on the self-reported APHAB (Cohen\n                      <jats:italic>d<\/jats:italic>\n                      = \u22120.5 [95% CI, \u22121.0 to 0]) and IOI-HA (effect size\n                      <jats:italic>r<\/jats:italic>\n                      = 0.3 [95% CI, 0.0-0.5]) but not speech recognition in noise. At the end of the 6-week trial, no meaningful differences were evident between the groups on any outcome measures.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion and relevance<\/jats:title>\n                    <jats:p>In this randomized clinical effectiveness trial, self-fitting OTC hearing aids with remote support yielded outcomes at 6 weeks post fitting comparable to those of hearing aids fitted using audiologist best practices. These findings suggest that self-fitting OTC hearing aids may provide an effective intervention for mild to moderate hearing loss.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial Registration<\/jats:title>\n                    <jats:p>\n                      ClinicalTrials.gov Identifier:\n                      <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/clinicaltrials.gov\/ct2\/show\/NCT05337748\">NCT05337748<\/jats:ext-link>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1001\/jamaoto.2023.0376","type":"journal-article","created":{"date-parts":[[2023,4,13]],"date-time":"2023-04-13T11:02:43Z","timestamp":1681383763000},"page":"522","source":"Crossref","is-referenced-by-count":90,"title":["Effectiveness of an Over-the-Counter Self-fitting Hearing Aid Compared With an Audiologist-Fitted Hearing Aid"],"prefix":"10.1001","volume":"149","author":[{"given":"Karina C.","family":"De Sousa","sequence":"first","affiliation":[{"name":"Department of Speech-Language Pathology and Audiology, University of Pretoria, Pretoria, South Africa"},{"name":"Virtual Hearing Lab, Collaborative Initiative Between the University of Colorado and the University of Pretoria, Aurora, Colorado"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vinaya","family":"Manchaiah","sequence":"additional","affiliation":[{"name":"Department of Speech-Language Pathology and Audiology, University of Pretoria, Pretoria, South Africa"},{"name":"Virtual Hearing Lab, Collaborative Initiative Between the University of Colorado and the University of Pretoria, Aurora, Colorado"},{"name":"Department of Otolaryngology\u2013Head and Neck Surgery, University of Colorado School of Medicine, Aurora"},{"name":"UCHealth Hearing and Balance, University of Colorado Hospital, Aurora"},{"name":"Department of Speech and Hearing, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David R.","family":"Moore","sequence":"additional","affiliation":[{"name":"Communication Sciences Research Center, Cincinnati Children\u2019s Hospital Medical Center and University of Cincinnati, Cincinnati, Ohio"},{"name":"Manchester Centre for Audiology and Deafness, University of Manchester, Manchester, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marien A.","family":"Graham","sequence":"additional","affiliation":[{"name":"Department of Science, Mathematics and Technology Education, University of Pretoria, Pretoria, South Africa"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"De Wet","family":"Swanepoel","sequence":"additional","affiliation":[{"name":"Department of Speech-Language Pathology and Audiology, University of Pretoria, Pretoria, South Africa"},{"name":"Virtual Hearing Lab, Collaborative Initiative Between the University of Colorado and the University of Pretoria, Aurora, Colorado"},{"name":"Department of Otolaryngology\u2013Head and Neck Surgery, University of Colorado School of Medicine, Aurora"},{"name":"Ear Science Institute Australia, Perth, Western Australia, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10","reference":[{"issue":"3","key":"ooi230014r2","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1177\/1084713810385712","article-title":"Factors influencing help seeking, hearing aid uptake, hearing aid use and satisfaction with hearing aids: a review of the literature.","volume":"14","author":"Knudsen","year":"2010","journal-title":"Trends Amplif"},{"issue":"2","key":"ooi230014r3","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1044\/1059-0889(2012\/12-0028)","article-title":"Older adults and hearing help-seeking behaviors.","volume":"21","author":"Saunders","year":"2012","journal-title":"Am J Audiol"},{"issue":"3","key":"ooi230014r4","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1001\/archinternmed.2011.1408","article-title":"Prevalence of hearing aid use among older adults in the United States.","volume":"172","author":"Chien","year":"2012","journal-title":"Arch Intern Med"},{"issue":"3S","key":"ooi230014r5","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1044\/2017_AJA-16-0135","article-title":"Findings from EuroTrak surveys from 2009 to 2015: hearing loss prevalence, hearing aid adoption, and benefits of hearing aid use.","volume":"26","author":"Bisgaard","year":"2017","journal-title":"Am J Audiol"},{"issue":"1","key":"ooi230014r6","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1097\/AUD.0b013e3181cbc783","article-title":"Guest editorial: accessible and affordable hearing health care for adults with mild to moderate hearing loss.","volume":"31","author":"Donahue","year":"2010","journal-title":"Ear Hear"},{"key":"ooi230014r7","doi-asserted-by":"publisher","first-page":"859","DOI":"10.2147\/CIA","article-title":"Applications of direct-to-consumer hearing devices for adults with hearing loss: a review.","volume":"12","author":"Manchaiah","year":"2017","journal-title":"Clin Interv Aging"},{"issue":"8","key":"ooi230014r8","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1001\/jama.2016.7916","article-title":"Priorities for improving hearing health care for adults: a report from the National Academies of Sciences, Engineering, and Medicine.","volume":"316","author":"Lin","year":"2016","journal-title":"JAMA"},{"issue":"4","key":"ooi230014r12","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1177\/1084713811427707","article-title":"A self-fitting hearing aid: need and concept.","volume":"15","author":"Convery","year":"2011","journal-title":"Trends Amplif"},{"issue":"4","key":"ooi230014r13","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1177\/1084713812444009","article-title":"Evidence on self-fitting hearing aids.","volume":"15","author":"Wong","year":"2011","journal-title":"Trends Amplif"},{"issue":"1","key":"ooi230014r14","doi-asserted-by":"publisher","first-page":"5","DOI":"10.3766\/jaaa.26.1.2","article-title":"Factors affecting reliability and validity of self-directed automatic in situ audiometry: implications for self-fitting hearing AIDS.","volume":"26","author":"Convery","year":"2015","journal-title":"J Am Acad Audiol"},{"issue":"12","key":"ooi230014r15","doi-asserted-by":"publisher","first-page":"868","DOI":"10.3109\/14992027.2010.503664","article-title":"Validity and reliability of in-situ air conduction thresholds measured through hearing aids coupled to closed and open instant-fit tips.","volume":"49","author":"O\u2019Brien","year":"2010","journal-title":"Int J Audiol"},{"issue":"1","key":"ooi230014r16","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1044\/1059-0889(2006\/009)","article-title":"Test-retest reliability of in situ unaided thresholds in adults.","volume":"15","author":"Smith-Olinde","year":"2006","journal-title":"Am J Audiol"},{"issue":"6","key":"ooi230014r17","doi-asserted-by":"publisher","first-page":"385","DOI":"10.3109\/14992027.2013.773407","article-title":"Hearing-aid assembly management among adults from culturally and linguistically diverse backgrounds: toward the feasibility of self-fitting hearing aids.","volume":"52","author":"Convery","year":"2013","journal-title":"Int J Audiol"},{"issue":"4","key":"ooi230014r18","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1177\/1084713811431694","article-title":"Management of hearing aid assembly by urban-dwelling hearing-impaired adults in a developed country: implications for a self-fitting hearing aid.","volume":"15","author":"Convery","year":"2011","journal-title":"Trends Amplif"},{"issue":"1","key":"ooi230014r19","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1044\/2017_AJA-16-0111","article-title":"The effects of service-delivery model and purchase price on hearing-aid outcomes in older adults: a randomized double-blind placebo-controlled clinical trial.","volume":"26","author":"Humes","year":"2017","journal-title":"Am J Audiol"},{"issue":"1","key":"ooi230014r20","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1044\/2018_AJA-18-0082","article-title":"A follow-up clinical trial evaluating the consumer-decides service delivery model.","volume":"28","author":"Humes","year":"2019","journal-title":"Am J Audiol"},{"key":"ooi230014r21","doi-asserted-by":"publisher","DOI":"10.1177\/2331216519900589","article-title":"Validation of a self-fitting method for over-the-counter hearing aids.","volume":"24","author":"Sabin","year":"2020","journal-title":"Trends Hear"},{"issue":"2","key":"ooi230014r23","first-page":"227","article-title":"Matching real-ear targets for adult hearing aid fittings: NAL-NL1 and DSL v5. 0 prescriptive formulae.","volume":"41","author":"Baker","year":"2017","journal-title":"Can J Speech Lang Audiol."},{"issue":"8","key":"ooi230014r24","doi-asserted-by":"publisher","first-page":"550","DOI":"10.3109\/14992021003713122","article-title":"Fit to targets, preferred listening levels, and self-reported outcomes for the DSL v5.0 a hearing aid prescription for adults.","volume":"49","author":"Polonenko","year":"2010","journal-title":"Int J Audiol"},{"issue":"1","key":"ooi230014r25","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1044\/2020_AJA-20-00085","article-title":"Toward a new evidence-based fitting paradigm for over-the-counter hearing aids.","volume":"30","author":"Urbanski","year":"2021","journal-title":"Am J Audiol"},{"issue":"2","key":"ooi230014r26","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1097\/00003446-199504000-00005","article-title":"The abbreviated profile of hearing aid benefit.","volume":"16","author":"Cox","year":"1995","journal-title":"Ear Hear"},{"issue":"1","key":"ooi230014r27","doi-asserted-by":"publisher","first-page":"30","DOI":"10.3109\/14992020209101309","article-title":"The International Outcome Inventory for Hearing Aids (IOI-HA): psychometric properties of the English version.","volume":"41","author":"Cox","year":"2002","journal-title":"Int J Audiol"},{"issue":"4 Pt 1","key":"ooi230014r28","doi-asserted-by":"publisher","first-page":"2395","DOI":"10.1121\/1.1784440","article-title":"Development of a quick speech-in-noise test for measuring signal-to-noise ratio loss in normal-hearing and hearing-impaired listeners.","volume":"116","author":"Killion","year":"2004","journal-title":"J Acoust Soc Am"},{"issue":"7","key":"ooi230014r29","doi-asserted-by":"publisher","first-page":"405","DOI":"10.3109\/14992027.2016.1172269","article-title":"Development and validation of a smartphone-based digits-in-noise hearing test in South African English.","volume":"55","author":"Potgieter","year":"2015","journal-title":"Int J Audiol"},{"issue":"4","key":"ooi230014r30","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1097\/AUD.0000000000000522","article-title":"The South African English smartphone digits-in-noise hearing test: effect of age, hearing loss, and speaking competence.","volume":"39","author":"Potgieter","year":"2018","journal-title":"Ear Hear"},{"issue":"3","key":"ooi230014r31","doi-asserted-by":"publisher","first-page":"27","DOI":"10.11621\/pir.2015.0303","article-title":"Effect size, confidence intervals and statistical power in psychological research.","volume":"8","author":"Arnoldo","year":"2015","journal-title":"Psychol Russia"},{"issue":"3","key":"ooi230014r32","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1177\/108471380500900303","article-title":"The WHO-DAS II: psychometric properties in the measurement of functional health status in adults with acquired hearing loss.","volume":"9","author":"Chisolm","year":"2005","journal-title":"Trends Amplif"},{"issue":"4","key":"ooi230014r34","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1159\/000506666","article-title":"Assessment of hearing aid benefit using patient-reported outcomes and audiologic measures.","volume":"25","author":"Dornhoffer","year":"2020","journal-title":"Audiol Neurootol"},{"key":"ooi230014r35","doi-asserted-by":"publisher","DOI":"10.1177\/2331216521999563","article-title":"Does probe-tube verification of real-ear hearing aid amplification characteristics improve outcomes in adults? a systematic review and meta-analysis.","volume":"25","author":"Almufarrij","year":"2021","journal-title":"Trends Hear"},{"key":"ooi230014r36","doi-asserted-by":"publisher","DOI":"10.1177\/2331216518820220","article-title":"Discrimination of gain increments in speech-shaped noises.","volume":"23","author":"Caswell-Midwinter","year":"2019","journal-title":"Trends Hear"},{"issue":"4","key":"ooi230014r37","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1177\/1084713812468511","article-title":"NAL-NL2 empirical adjustments.","volume":"16","author":"Keidser","year":"2012","journal-title":"Trends Amplif"},{"key":"ooi230014r1","unstructured":"World Health Organization. World report on hearing. March 3, 2021. Accessed July 7, 2021. https:\/\/www.who.int\/publications\/i\/item\/9789240020481"},{"key":"ooi230014r9","unstructured":"National Institute on Deafness and Communication Orders. Over-the-counter hearing aids. Updated August 16, 2022. Accessed April 13, 2022. https:\/\/www.nidcd.nih.gov\/health\/over-counter-hearing-aids"},{"key":"ooi230014r10","unstructured":"US Food and Drug Administration. FDA finalizes historic rule enabling access to over-the-counter hearing aids for millions of Americans. August 16, 2022. Accessed August 26, 2022. https:\/\/www.fda.gov\/news-events\/press-announcements\/fda-finalizes-historic-rule-enabling-access-over-counter-hearing-aids-millions-americans"},{"key":"ooi230014r11","unstructured":"Roland? C, Morris? A. Listen up: you can now buy hearing aids without a prescription. The Washington Post. October 16, 2022. Accessed October 20, 2022. https:\/\/www.washingtonpost.com\/business\/2022\/10\/16\/hearing-aids-retail-consumer\/"},{"key":"ooi230014r22","unstructured":"Lexie Hearing. Lexie Lumen OTC hearing aid. Accessed October 20, 2022. https:\/\/lexiehearing.com\/us\/lexie-lumen-hearing-aid"},{"key":"ooi230014r33","unstructured":"American Speech Language and Hearing Association (ASHA). Hearing aids for adults. Accessed October 15, 2022. https:\/\/www.asha.org\/Practice-Portal\/Professional-Issues\/Hearing-Aids-for-Adults\/"}],"container-title":["JAMA Otolaryngology\u2013Head &amp; Neck Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/jamanetwork.com\/journals\/jamaotolaryngology\/articlepdf\/2803832\/jamaotolaryngology_de_sousa_2023_oi_230014_1685130124.92784.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,8]],"date-time":"2023-06-08T11:01:43Z","timestamp":1686222103000},"score":1,"resource":{"primary":{"URL":"https:\/\/jamanetwork.com\/journals\/jamaotolaryngology\/fullarticle\/2803832"}},"subtitle":["A Randomized Clinical Trial"],"short-title":[],"issued":{"date-parts":[[2023,6,1]]},"references-count":37,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2023,6,1]]}},"URL":"https:\/\/doi.org\/10.1001\/jamaoto.2023.0376","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/2022.12.12.22283331","asserted-by":"object"}]},"ISSN":["2168-6181"],"issn-type":[{"value":"2168-6181","type":"print"}],"subject":[],"published":{"date-parts":[[2023,6,1]]}}}