{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T19:01:32Z","timestamp":1774638092146,"version":"3.50.1"},"update-to":[{"DOI":"10.1002\/14651858.cd007897.pub2","type":"new_version","label":"New version","source":"publisher","updated":{"date-parts":[[2015,2,25]],"date-time":"2015-02-25T00:00:00Z","timestamp":1424822400000}}],"reference-count":75,"publisher":"Wiley","issue":"2","content-domain":{"domain":["wiley.com","cochranelibrary.com"],"crossmark-restriction":true},"short-container-title":[],"DOI":"10.1002\/14651858.cd007897.pub3","type":"journal-article","created":{"date-parts":[[2015,2,25]],"date-time":"2015-02-25T22:16:58Z","timestamp":1424902618000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":27,"title":["Remediating buildings damaged by dampness and mould for preventing or reducing respiratory tract symptoms, infections and asthma"],"prefix":"10.1002","volume":"2015","author":[{"given":"Riitta","family":"Sauni","sequence":"first","affiliation":[{"name":"Finnish Institute of Occupational Health; P.O.Box 486 Tampere Finland FI-33101"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos H","family":"Verbeek","sequence":"additional","affiliation":[{"name":"Finnish Institute of Occupational Health; Cochrane Occupational Safety and Health Review Group; PO Box 310 Kuopio Finland 70101"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jukka","family":"Uitti","sequence":"additional","affiliation":[{"name":"Finnish Institute of Occupational Health; P.O.Box 486 Tampere Finland FI-33101"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Merja","family":"Jauhiainen","sequence":"additional","affiliation":[{"name":"Finnish Institute of Occupational Health; Knowledge Transfer Team; Topeliuksenkatu 41aA Helsinki Finland FIN-00250"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kathleen","family":"Kreiss","sequence":"additional","affiliation":[{"name":"National Institute for Occupational Safety and Health; Division of Respiratory Disease Studies; 1095 Willowdale Road Morgantown West Virginia USA 26505"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Torben","family":"Sigsgaard","sequence":"additional","affiliation":[{"name":"Aarhus University; School of Public Health; Aarhus Jutland Denmark"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2015,2,25]]},"reference":[{"key":"10.1002\/14651858.CD007897.pub3-BIB0001|cit1","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1034\/j.1600-0668.2000.010001057.x","article-title":"Improved health after intervention on a school with moisture problems","volume":"10","author":"\u00c5hman","year":"2000","journal-title":"Indoor Air"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0002|cit2","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1136\/thx.2006.070847","article-title":"Effects on patients with asthma of eradicating visible indoor mould: a randomised controlled study","volume":"62","author":"Burr","year":"2007","journal-title":"Thorax"},{"issue":"19","key":"10.1002\/14651858.CD007897.pub3-BIB0003|cit3","doi-asserted-by":"crossref","first-page":"3628","DOI":"10.1016\/j.scitotenv.2011.06.011","article-title":"Investigation of different approaches to reduce allergens in asthmatic children's homes; the Breath of Fresh Air Project, Cornwall, UK","volume":"409","author":"Eick","year":"2011","journal-title":"Science of the Total Environment"},{"issue":"6","key":"10.1002\/14651858.CD007897.pub3-BIB0004|cit4","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1111\/j.1600-0668.2012.00785.x","article-title":"Assessment of airborne exposures and health in flooded homes undergoing renovation","volume":"22","author":"Hoppe","year":"2012","journal-title":"Indoor Air"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0005|cit5","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1136\/bmj.39070.573032.80","article-title":"Effect of insulating existing houses on health inequality: cluster randomised study in the community","volume":"334","author":"Howden-Chapman","year":"2007","journal-title":"BMJ"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0006|cit6","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1080\/10473220117482","article-title":"Allergic respiratory disease and fungal remediation on a building in a subtropical climate","volume":"16","author":"Jarvis","year":"2001","journal-title":"Applied Occupational and Environmental Hygiene"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0007|cit7","doi-asserted-by":"crossref","first-page":"1574","DOI":"10.1289\/ehp.8742","article-title":"Reduction in asthma morbidity in children as a result of home remediation aimed at moisture sources","volume":"114","author":"Kercsmar","year":"2006","journal-title":"Environmental Health Perspectives"},{"issue":"3","key":"10.1002\/14651858.CD007897.pub3-BIB0008|cit8","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1039\/B615459J","article-title":"Effects of moisture damage and renovation on microbial conditions and pupils' health in two schools - a longitudinal analysis of five years","volume":"9","author":"Lignell","year":"2007","journal-title":"Journal of Environmental Monitoring"},{"issue":"Suppl 10","key":"10.1002\/14651858.CD007897.pub3-BIB0009|cit9","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1111\/j.1600-0668.2005.00357.x","article-title":"Effects of moisture-damage repairs on microbial exposure and symptoms in school children","volume":"15","author":"Meklin","year":"2005","journal-title":"Indoor Air"},{"issue":"3","key":"10.1002\/14651858.CD007897.pub3-BIB0010|cit10","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1039\/B615459J","article-title":"Effects of moisture damage and renovation on microbial conditions and pupils' health in two schools - a longitudinal analysis of five years","volume":"9","author":"Lignell","year":"2007","journal-title":"Journal of Environmental Monitoring"},{"issue":"Suppl 10","key":"10.1002\/14651858.CD007897.pub3-BIB0011|cit11","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1111\/j.1600-0668.2005.00357.x","article-title":"Effects of moisture-damage repairs on microbial exposure and symptoms in school children","volume":"15","author":"Meklin","year":"2005","journal-title":"Indoor Air"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0012|cit12","first-page":"36","article-title":"The remediation of mold damaged school - a three year follow-up study on teachers' health","volume":"12","author":"Patovirta","year":"2004","journal-title":"Central European Journal of Public Health"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0013|cit13","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1080\/00039890009604038","article-title":"Respiratory morbidity among children following renovation of a water-damaged school","volume":"55","author":"Savilahti","year":"2000","journal-title":"Archives of Environmental Health"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0014|cit14","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.healthplace.2005.10.004","article-title":"\"The walls were so damp and cold\" fuel poverty and ill health in Northern Ireland: results from a housing intervention","volume":"13","author":"Shortt","year":"2007","journal-title":"Health & Place"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0015|cit15","article-title":"Evaluation of dampness-associated respiratory symptoms with relocation of staff during remediation of an elementary school - North Carolina","volume-title":"NIOSH Health hazard evaluation report: HETA-2009-0172-3124. www.cdc.gov\/niosh\/hhe\/reports\/pdfs\/2009-0172-3124.pdf","author":"Bailey","year":"2009"},{"issue":"4","key":"10.1002\/14651858.CD007897.pub3-BIB0016|cit16","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1542\/hpeds.2013-0047","article-title":"Connecting at-risk inpatient asthmatics to a community-based program to reduce home environmental risks: care system redesign using quality improvement methods","volume":"3","author":"Beck","year":"2013","journal-title":"Hospital Pediatrics"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0017|cit17","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1080\/15298668391404581","article-title":"Exposures to respirable, airborne Penicillium from a contaminated ventilation system: clinical, environmental and epidemiological aspects","volume":"44","author":"Bernstein","year":"1983","journal-title":"American Industrial Hygiene Association Journal"},{"issue":"Suppl","key":"10.1002\/14651858.CD007897.pub3-BIB0018|cit18","doi-asserted-by":"crossref","first-page":"262","DOI":"10.2105\/AJPH.2011.300164","article-title":"Effectiveness of a household environmental health intervention delivered by rural public health nurses","volume":"101","author":"Butterfield","year":"2011","journal-title":"American Journal of Public Health"},{"issue":"2","key":"10.1002\/14651858.CD007897.pub3-BIB0019|cit19","doi-asserted-by":"crossref","first-page":"AB64","DOI":"10.1016\/j.jaci.2011.12.735","article-title":"Indoor airborne spore levels before and after healthy homes education and remediation","volume":"129","author":"Dhar","year":"2012","journal-title":"Journal of Allergy and Clinical Immunology"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0020|cit20","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1186\/1471-2458-13-123","article-title":"The impact of pre- and postnatal exposures on allergy related diseases in childhood: a controlled multicentre intervention study in primary health care","volume":"13","author":"Dotterud","year":"2013","journal-title":"BMC Public Health"},{"issue":"1","key":"10.1002\/14651858.CD007897.pub3-BIB0021|cit21","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.jaci.2013.06.003","article-title":"A simulation model of building intervention impacts on indoor environmental quality, pediatric asthma, and costs","volume":"133","author":"Fabian","year":"2014","journal-title":"Journal of Allergy and Clinical Immunology"},{"issue":"1","key":"10.1002\/14651858.CD007897.pub3-BIB0022|cit22","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1353\/cpr.2013.0010","article-title":"Impact of LEED-certified affordable housing on asthma in the South Bronx","volume":"7","author":"Garland","year":"2013","journal-title":"Progress in Community Health Partnerships: Research, Education, and Action"},{"issue":"Suppl 3","key":"10.1002\/14651858.CD007897.pub3-BIB0023|cit23","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1289\/ehp.99107s3509","article-title":"An approach to management of critical indoor air problems in school buildings","volume":"107","author":"Haverinen","year":"1999","journal-title":"Environmental Health Perspectives"},{"issue":"Suppl 1","key":"10.1002\/14651858.CD007897.pub3-BIB0024|cit24","first-page":"58","article-title":"Estimating effects of moisture damage repairs on students' health - a long-term intervention study","volume":"14","author":"Haverinen-Shaughnessy","year":"2004","journal-title":"Journal of Exposure Analysis and Environmental Epidemiology"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0025|cit25","doi-asserted-by":"crossref","first-page":"2600","DOI":"10.1016\/j.socscimed.2005.04.049","article-title":"Retrofitting houses with insulation to reduce health inequalities: aims and methods of a clustered, randomised community-based trial","volume":"61","author":"Howden-Chapman","year":"2005","journal-title":"Social Science & Medicine"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0026|cit26","first-page":"A4649","article-title":"Three years of dampness remediation and respiratory health of an office worker cohort","volume":"181","author":"Iossifova","year":"2010","journal-title":"American Journal of Respiratory and Critical Care Medicine"},{"issue":"4","key":"10.1002\/14651858.CD007897.pub3-BIB0027|cit27","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1002\/ajim.20910","article-title":"Lack of respiratory improvement following remediation of a water-damaged office building","volume":"54","author":"Iossifova","year":"2011","journal-title":"American Journal of Industrial Medicine"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0028|cit28","doi-asserted-by":"crossref","first-page":"377","DOI":"10.2500\/aap.2009.30.3257","article-title":"Low-cost interventions improve indoor air quality and children's health","volume":"30","author":"Johnson","year":"2009","journal-title":"Allergy & Asthma Proceedings"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0029|cit29","doi-asserted-by":"crossref","first-page":"793","DOI":"10.1136\/jech.2007.067835","article-title":"The effect of improving the thermal quality of cold housing on blood pressure and general health: a research note","volume":"62","author":"Lloyd","year":"2008","journal-title":"Journal of Epidemiology and Community Health"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0030|cit30","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.1056\/NEJMoa032097","article-title":"Results of a home-based environmental intervention among urban children with asthma","volume":"351","author":"Morgan","year":"2004","journal-title":"New England Journal of Medicine"},{"issue":"5","key":"10.1002\/14651858.CD007897.pub3-BIB0031|cit31","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1111\/j.1600-0668.2011.00717.x","article-title":"Respiratory symptoms, perceived air quality and physiological signs in elementary school pupils in relation to displacement and mixing ventilation system: an intervention study","volume":"21","author":"Norback","year":"2011","journal-title":"Indoor Air"},{"issue":"9","key":"10.1002\/14651858.CD007897.pub3-BIB0032|cit32","doi-asserted-by":"crossref","first-page":"911","DOI":"10.3109\/02770903.2012.724131","article-title":"Environmental improvements brought by the legal interventions in the homes of poorly controlled inner-city adult asthmatic patients: a proof-of-concept study","volume":"49","author":"O'Sullivan","year":"2012","journal-title":"Journal of Asthma"},{"issue":"11","key":"10.1002\/14651858.CD007897.pub3-BIB0033|cit33","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1080\/15459624.2012.724650","article-title":"Occurrence of household mold and efficacy of sodium hypochlorite disinfectant","volume":"9","author":"Reynolds","year":"2012","journal-title":"Journal of Occupational and Environmental Hygiene"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0034|cit34","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/S1081-1206(10)62142-4","article-title":"Fungal contamination of elementary schools: a new environmental hazard","volume":"90","author":"Santilli","year":"2003","journal-title":"Annals of Allergy, Asthma & Immunology"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0035|cit35","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/00003727-200001000-00003","article-title":"Home remediation for respiratory health: a feasibility study","volume":"22","author":"Stubner","year":"2000","journal-title":"Family & Community Health"},{"issue":"7","key":"10.1002\/14651858.CD007897.pub3-BIB0036|cit36","doi-asserted-by":"crossref","first-page":"729","DOI":"10.3109\/02770903.2013.796971","article-title":"A multifaceted community-based asthma intervention in Chicago: effects of trigger reduction and self-management education on asthma morbidity","volume":"50","author":"Turyk","year":"2013","journal-title":"Journal of Asthma"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0037|cit37","first-page":"43","article-title":"A multifaceted, home based, environmental intervention reduced asthma related morbidity in children with atopic asthma","volume":"8","author":"Wilkerson","year":"2004","journal-title":"Evidence-based Nursing"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0038|cit38","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/j.scitotenv.2012.04.040","article-title":"Dampness and moulds in workplace buildings: associations with incidence and remission of sick building syndrome (SBS) and biomarkers of inflammation in a 10 year follow-up study","volume":"430","author":"Zhang","year":"2012","journal-title":"Science of the Total Environment"},{"issue":"2","key":"10.1002\/14651858.CD007897.pub3-BIB0039|cit39","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1034\/j.1600-0668.2001.110202.x","article-title":"Dampness in buildings and health. Nordic interdisciplinary review of the scientific evidence on associations between exposure to \"dampness\" in buildings and health effects (NORDDAMP)","volume":"11","author":"Bornehag","year":"2001","journal-title":"Indoor Air"},{"issue":"4","key":"10.1002\/14651858.CD007897.pub3-BIB0040|cit40","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1111\/j.1600-0668.2004.00240.x","article-title":"Dampness in buildings as a risk factor for health effects, EUROEXPO: a multidisciplinary review of the literature (1998-2000) on dampness and mite exposure in buildings and health effects","volume":"14","author":"Bornehag","year":"2004","journal-title":"Indoor Air"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0041|cit41","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1183\/09031936.93.02090940","article-title":"Validity and repeatability of the IUATLD (1984) Bronchial Symptoms Questionnaire: an international comparison","volume":"2","author":"Burney","year":"1989","journal-title":"European Respiratory Journal"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0042|cit42","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1136\/jech.52.6.377","article-title":"The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions","volume":"52","author":"Downs","year":"1998","journal-title":"Journal of Epidemiology and Community Health"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0043|cit43","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1034\/j.1600-0668.2002.02141.x","article-title":"Building-related symptoms and mold: two-step intervention study","volume":"12","author":"Ebbeh\u00f8j","year":"2002","journal-title":"Indoor Air"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0044|cit44","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1111\/j.1600-0668.2007.00475.x","article-title":"Meta-analyses of the associations of respiratory health effects with dampness and mold in homes","volume":"17","author":"Fisk","year":"2007","journal-title":"Indoor Air"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0045|cit45","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.scitotenv.2008.03.033","article-title":"Monitoring success of remediation: seven case studies of moisture and mold damaged buildings","volume":"399","author":"Haverinen-Shaughnessy","year":"2008","journal-title":"Science of the Total Environment"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0046|cit46","unstructured":"Higgins JPT Green S (editors) Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011]. The Cochrane Collaboration, 2011 Available from www.cochrane-handbook.org"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0047|cit47","volume-title":"Immunologic and Pulmonary Reactivity in Schoolchildren from Moisture and Mould-damaged School Buildings: a Three-year Follow-up Study","author":"Immonen","year":"2002"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0048|cit48","first-page":"183","article-title":"Human health effects associated with damp indoor environments","volume-title":"Damp Indoor Spaces and Health","author":"Institute of Medicine","year":"2004"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0049|cit49","first-page":"29","article-title":"Damp buildings","volume-title":"Damp Indoor Spaces and Health","author":"Institute of Medicine","year":"2004"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0050|cit50","volume-title":"Ammattitatudit 2007 (Statistics of Occupational Diseases)","author":"Karjalainen","year":"2007"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0051|cit51","unstructured":"Koivisto J J\u00e4\u00e4skel\u00e4inen E Damages due to dampness in apartment buildings - survey of prevalence and reparation costs Publications of the National Public Health Institute, Series B 9 1996"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0052|cit52","doi-asserted-by":"crossref","first-page":"1363","DOI":"10.1183\/09031936.99.14613639","article-title":"The relationship between moisture or mould observations in houses and the state of their occupants","volume":"14","author":"Koskinen","year":"1999","journal-title":"European Respiratory Journal"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0053|cit53","volume-title":"Moisture, Mold and Health","author":"Koskinen","year":"1999"},{"issue":"Suppl 5","key":"10.1002\/14651858.CD007897.pub3-BIB0054|cit54","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/PHH.0b013e3181ddcbd9","article-title":"Housing interventions and control of asthma-related indoor biologic agents: a review of the evidence","volume":"16","author":"Krieger","year":"2010","journal-title":"Journal of Public Health Management and Practice"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0055|cit55","doi-asserted-by":"crossref","first-page":"952\u20138","DOI":"10.1164\/rccm.200301-137OC","article-title":"Clinical diagnosis of active hypersensitivity pneumonitis","volume":"168","author":"Lacasse","year":"2003","journal-title":"American Journal of Respiratory and Critical Care Medicine"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0056|cit56","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1136\/oem.2002.005835","article-title":"Psychosocial work environment and indoor air problems: a questionnaire as a means of problem diagnosis","volume":"61","author":"Lahtinen","year":"2004","journal-title":"Occupational and Environmental Medicine"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0057|cit57","unstructured":"Lefebvre C Manheimer E Glanville J Chapter 6: Searching for studies. In: Higgins JPT, Green S (editors). Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011]. The Cochrane Collaboration, 2011 Available from www.cochrane-handbook.org"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0058|cit58","unstructured":"Meklin T Microbial exposure and health in schools - effects of moisture damage and remediation National Public Health Institute (academic dissertation). Kuopio University Printing Office: Kuopio 2002"},{"issue":"6","key":"10.1002\/14651858.CD007897.pub3-BIB0059|cit59","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1289\/ehp.1002410","article-title":"Respiratory and allergic health effects of dampness, mold and dampness-related agents: a review of the epidemiologic evidence","volume":"119","author":"Mendell","year":"2011","journal-title":"Environmental Health Perspectives"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0060|cit60","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1111\/j.1600-0668.1998.tb00007.x","article-title":"Prevalence of moisture\u00a0problems in Finnish houses","volume":"Suppl 4","author":"Nevalainen","year":"1998","journal-title":"Indoor Air"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0061|cit61","unstructured":"Partanen P J\u00e4\u00e4skel\u00e4inen E Nevalainen A Husman T Hyv\u00e4rinen A Korhonen L Mould damages in small buildings - survey of prevalence and reparation costs Publications of National Public Health Institute, Series B 6 1995"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0062|cit62","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1080\/09603120400012876","article-title":"Effects of mould remediation on school teachers' health","volume":"14","author":"Patovirta","year":"2004","journal-title":"International Journal of Environmental Health Research"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0063|cit63","volume-title":"Teachers' Health in Moisture-damaged Schools - a Follow-up Study","author":"Patovirta","year":"2005"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0064|cit64","doi-asserted-by":"crossref","first-page":"948","DOI":"10.1183\/09031936.05.00035205","article-title":"Interpretative strategies for lung function tests. Series ATS\/ERS Task Force: Standardisation of lung function testing","volume":"26","author":"Pellegrino","year":"2005","journal-title":"European Respiratory Journal"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0065|cit65","unstructured":"The Nordic Cochrane Centre, The Cochrane Collaboration Review Manager (RevMan) 2014"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0066|cit66","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1034\/j.1600-0668.2002.01112.x","article-title":"Slowly decreasing mucosal hyperreactivity years after working in a school with moisture problems","volume":"12","author":"Rudblad","year":"2002","journal-title":"Indoor Air"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0067|cit67","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.1136\/bmj.297.6658.1223","article-title":"Damp housing and childhood asthma: validation of reporting of symptoms","volume":"297","author":"Strachan","year":"1988","journal-title":"BMJ"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0068|cit68","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1002\/(SICI)1097-0274(199808)34:2<183::AID-AJIM12>3.0.CO;2-R","article-title":"Toxigenic fungi in a water-damaged building: an intervention study","volume":"34","author":"Sudakin","year":"1998","journal-title":"American Journal of Industrial Medicine"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0069|cit69","volume-title":"Moisture and Mould Problems in School Buildings","author":"Taskinen","year":"2001"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0070|cit70","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1136\/bmj.323.7306.187","article-title":"Health effects of housing improvement: systematic review of intervention studies","volume":"323","author":"Thomson","year":"2001","journal-title":"BMJ"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0071|cit71","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1378\/chest.104.2.600","article-title":"Asthma and asthma-like symptoms in adults assessed by questionnaires. A literature review","volume":"104","author":"Toren","year":"1993","journal-title":"Chest"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0072|cit72","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.jclinepi.2005.03.019","article-title":"Self-reported asthma was biased in relation to disease severity while reported year of asthma onset was accurate","volume":"59","author":"Toren","year":"2006","journal-title":"Journal of Clinical Epidemiology"},{"key":"10.1002\/14651858.CD007897.pub3-BIB0073|cit73","volume-title":"WHO guidelines for indoor air quality: dampness and mould","author":"WHO","year":"2009"},{"issue":"3","key":"10.1002\/14651858.CD007897.pub3-BIB0074|cit74","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD007897","article-title":"Remediating buildings damaged by dampness and mould for preventing respiratory tract symptoms, infections and asthma","author":"Sauni","year":"2009","journal-title":"Cochrane Database of Systematic Reviews"},{"issue":"9","key":"10.1002\/14651858.CD007897.pub3-BIB0075|cit75","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD007897.pub2","article-title":"Remediating buildings damaged by dampness and mould for preventing or reducing respiratory tract symptoms, infections and asthma","author":"Sauni","year":"2011","journal-title":"Cochrane Database of Systematic Reviews"}],"container-title":["Cochrane Database of Systematic Reviews"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/onlinelibrary.wiley.com\/wol1\/doi\/10.1002\/14651858.CD007897.pub3\/fullpdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,28]],"date-time":"2024-11-28T03:17:37Z","timestamp":1732763857000},"score":1,"resource":{"primary":{"URL":"http:\/\/doi.wiley.com\/10.1002\/14651858.CD007897.pub3"}},"subtitle":[],"editor":[{"name":"Cochrane Acute Respiratory Infections Group","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2015,2,25]]},"references-count":75,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2015,2]]}},"URL":"https:\/\/doi.org\/10.1002\/14651858.cd007897.pub3","relation":{},"ISSN":["1465-1858"],"issn-type":[{"value":"1465-1858","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,2,25]]}}}