{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,18]],"date-time":"2026-10-18T10:08:27Z","timestamp":1792318107848,"version":"4.4.0"},"update-to":[{"DOI":"10.1002\/14651858.cd008942","type":"new_version","label":"New version","source":"publisher","updated":{"date-parts":[[2016,8,21]],"date-time":"2016-08-21T00:00:00Z","timestamp":1471737600000}}],"reference-count":22,"publisher":"Wiley","issue":"8","content-domain":{"domain":["wiley.com","cochranelibrary.com"],"crossmark-restriction":true},"short-container-title":[],"DOI":"10.1002\/14651858.cd008942.pub2","type":"journal-article","created":{"date-parts":[[2016,8,21]],"date-time":"2016-08-21T13:21:11Z","timestamp":1471785671000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Venous cutdown versus the Seldinger technique for placement of totally implantable venous access ports"],"prefix":"10.1002","volume":"2016","author":[{"given":"Charlie C-T","family":"Hsu","sequence":"first","affiliation":[{"name":"Princess Alexandra Hospital; Department of Medical Imaging; 199 Ipswich Road Brisbane Queensland Australia 4102"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gigi NC","family":"Kwan","sequence":"additional","affiliation":[{"name":"Princess Alexandra Hospital; Department of Medical Imaging; 199 Ipswich Road Brisbane Queensland Australia 4102"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hannah","family":"Evans-Barns","sequence":"additional","affiliation":[{"name":"University of Melbourne; Faculty of Medicine, Dentistry and Health Sciences; Grattan Street, Parkville Melbourne Victoria Australia 3010"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John A","family":"Rophael","sequence":"additional","affiliation":[{"name":"University of Melbourne; Department of Surgery - St Vincent's Hospital; 41 Victoria Parade Fitzroy Victoria Australia 3065"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mieke L","family":"van Driel","sequence":"additional","affiliation":[{"name":"The University of Queensland; Discipline of General Practice, School of Medicine; Brisbane Queensland Australia 4029"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2016,8,21]]},"reference":[{"issue":"5","key":"10.1002\/14651858.CD008942.pub2-BIB0001|cit1","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1093\/annonc\/mdn701","article-title":"Best choice of central venous insertion site for the prevention of catheter-related complications in adult patients who need cancer therapy: a randomized trial","volume":"20","author":"Biffi","year":"2009","journal-title":"Annals of Oncology"},{"issue":"8","key":"10.1002\/14651858.CD008942.pub2-BIB0002|cit2","first-page":"52","article-title":"Subcutaneous venous reservoirs: dissection versus puncture","volume":"26","author":"Bold\u00f3","year":"2003","journal-title":"Oncolog\u00eda"},{"issue":"8","key":"10.1002\/14651858.CD008942.pub2-BIB0003|cit3","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.jclinane.2007.06.016","article-title":"Experience of anesthesiologists with percutaneous nonangiographic venous access","volume":"19","author":"Chen","year":"2007","journal-title":"Journal of Clinical Anesthesia"},{"issue":"4","key":"10.1002\/14651858.CD008942.pub2-BIB0004|cit4","first-page":"495","article-title":"Prospective randomised study of cephalic vein cut-down versus subclavian vein puncture technique in the implantation of subcutaneous venous access devices","volume":"54","author":"D'Angelo","year":"2002","journal-title":"Chirurgia Italiana"},{"issue":"2","key":"10.1002\/14651858.CD008942.pub2-BIB0005|cit5","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1002\/bjs.6457","article-title":"Randomized clinical trial of a modified Seldinger technique for open central venous cannulation for implantable access devices","volume":"96","author":"Knebel","year":"2009","journal-title":"The British Journal of Surgery"},{"issue":"6","key":"10.1002\/14651858.CD008942.pub2-BIB0006|cit6","doi-asserted-by":"crossref","first-page":"1111","DOI":"10.1097\/SLA.0b013e318214ba21","article-title":"Insertion of totally implantable venous access devices: an expertise-based, randomized, controlled trial","volume":"253","author":"Knebel","year":"2011","journal-title":"Annals of Surgery"},{"issue":"10","key":"10.1002\/14651858.CD008942.pub2-BIB0007|cit7","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1002\/bjs.6730","article-title":"Randomized clinical trial comparing venous cutdown with the Seldinger technique for placement of implantable venous access ports","volume":"96","author":"Nocito","year":"2009","journal-title":"British Journal of Surgery"},{"issue":"3","key":"10.1002\/14651858.CD008942.pub2-BIB0008|cit8","first-page":"305","article-title":"Totally implantable venous access ports: a clinical trial comparing percutaneous versus surgical technique","volume":"58","author":"Riapisarda","year":"2006","journal-title":"Chirurgia Italiana"},{"issue":"2","key":"10.1002\/14651858.CD008942.pub2-BIB0009|cit9","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1002\/pbc.23220","article-title":"Long-term complications in totally implantable venous access devices: randomized study comparing subclavian and internal jugular vein puncture","volume":"58","author":"Ribeiro","year":"2012","journal-title":"Pediatric Blood and Cancer"},{"issue":"6","key":"10.1002\/14651858.CD008942.pub2-BIB0010|cit10","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1016\/S0748-7983(97)93205-4","article-title":"Alternative insertion sites for permanent central venous access devices","volume":"23","author":"D'Angelo","year":"1997","journal-title":"European Journal of Surgical Oncology"},{"issue":"2","key":"10.1002\/14651858.CD008942.pub2-BIB0011|cit11","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1007\/BF01616826","article-title":"Long-term central venous access catheters: A prospective randomized trial comparing percutaneous and cut-down methods of insertion","volume":"8","author":"Munro","year":"1999","journal-title":"International Journal of Angiology"},{"key":"10.1002\/14651858.CD008942.pub2-BIB0012|cit12","unstructured":"NCT01584193 Ultrasound-guided subclavian vein puncture versus cephalic vein dissection for venous access port implantation http:\/\/clinicaltrials.gov\/ct2\/show\/NCT01584193 (accessed August 2015)"},{"key":"10.1002\/14651858.CD008942.pub2-BIB0013|cit13","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1186\/s13063-015-0643-z","article-title":"Frequency of pneumothorax and haemothorax after primary open versus closed implantation strategies for insertion of a totally implantable venous access port in oncological patients: Study protocol for a randomised controlled trial","volume":"16","author":"Huttner","year":"2015","journal-title":"Trials"},{"issue":"7454","key":"10.1002\/14651858.CD008942.pub2-BIB0014|cit14","doi-asserted-by":"crossref","first-page":"1490","DOI":"10.1136\/bmj.328.7454.1490","article-title":"Grading quality of evidence and strength of recommendations","volume":"328","author":"Atkins","year":"2004","journal-title":"BMJ"},{"issue":"4","key":"10.1002\/14651858.CD008942.pub2-BIB0015|cit15","doi-asserted-by":"crossref","first-page":"1267","DOI":"10.1200\/JCO.1999.17.4.1267","article-title":"Totally implantable venous access ports systems for patients receiving chemotherapy for solid tissue malignancies: a randomized controlled clinical trial examining the safety, efficacy, costs, and impact on quality of life","volume":"17","author":"Bow","year":"1999","journal-title":"Journal of Clinical Oncology"},{"issue":"9","key":"10.1002\/14651858.CD008942.pub2-BIB0016|cit16","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1001\/archsurg.136.9.1050","article-title":"Totally implantable venous access devices implanted surgically: a retrospective study on early and late complications","volume":"136","author":"Carlo","year":"2001","journal-title":"Archives of Surgery"},{"issue":"6","key":"10.1002\/14651858.CD008942.pub2-BIB0017|cit17","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.1245\/s10434-010-1005-4","article-title":"Increased use of percutaneous technique for totally implantable venous access devices. Is it real progress? A 27-year comprehensive review on early complications","volume":"17","author":"Carlo","year":"2010","journal-title":"Annals of Surgical Oncology"},{"key":"10.1002\/14651858.CD008942.pub2-BIB0018|cit18","unstructured":"Higgins JPT Green S (editors) Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011]. The Cochrane Collaboration, 2011 Available from www.cochrane-handbook.org"},{"issue":"7411","key":"10.1002\/14651858.CD008942.pub2-BIB0019|cit19","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1136\/bmj.327.7411.361","article-title":"Ultrasonic locating devices for central venous cannulation: meta-analysis","volume":"327","author":"Hind","year":"2003","journal-title":"BMJ"},{"issue":"7","key":"10.1002\/14651858.CD008942.pub2-BIB0020|cit20","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.clon.2007.04.003","article-title":"A comparison of Hickman line- and Port-a-Cath-associated complications in patients with solid tumours undergoing chemotherapy","volume":"19","author":"Ng","year":"2007","journal-title":"Clinical Oncology (Royal College of Radiologist (Great Britain))"},{"issue":"10","key":"10.1002\/14651858.CD008942.pub2-BIB0021|cit21","doi-asserted-by":"crossref","first-page":"1046","DOI":"10.1016\/S0895-4356(01)00377-8","article-title":"Funnel plots for detecting bias in meta-analysis: guidelines on choice of axis","volume":"54","author":"Sterne","year":"2001","journal-title":"Journal of Clinical Epidemiology"},{"issue":"1","key":"10.1002\/14651858.CD008942.pub2-BIB0022|cit22","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD008942","article-title":"Venous cutdown versus the Seldinger technique for placement of totally implantable venous access ports","author":"Hsu","year":"2011","journal-title":"Cochrane Database of Systematic Reviews"}],"container-title":["Cochrane Database of Systematic Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full\/10.1002\/14651858.CD008942.pub2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,20]],"date-time":"2024-06-20T01:53:01Z","timestamp":1718848381000},"score":1,"resource":{"primary":{"URL":"http:\/\/doi.wiley.com\/10.1002\/14651858.CD008942.pub2"}},"subtitle":[],"editor":[{"name":"Cochrane Vascular Group","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2016,8,21]]},"references-count":22,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2016,8]]}},"URL":"https:\/\/doi.org\/10.1002\/14651858.cd008942.pub2","relation":{},"ISSN":["1465-1858"],"issn-type":[{"value":"1465-1858","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,8,21]]}}}