{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T18:36:27Z","timestamp":1774377387208,"version":"3.50.1"},"update-to":[{"DOI":"10.1002\/14651858.cd011656","type":"new_version","label":"New version","source":"publisher","updated":{"date-parts":[[2015,11,18]],"date-time":"2015-11-18T00:00:00Z","timestamp":1447804800000}}],"reference-count":61,"publisher":"Wiley","issue":"11","content-domain":{"domain":["wiley.com","cochranelibrary.com"],"crossmark-restriction":true},"short-container-title":[],"DOI":"10.1002\/14651858.cd011656.pub2","type":"journal-article","created":{"date-parts":[[2015,11,18]],"date-time":"2015-11-18T04:34:56Z","timestamp":1447821296000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Effectiveness and risks of cricoid pressure during rapid sequence induction for endotracheal intubation"],"prefix":"10.1002","volume":"2015","author":[{"given":"Catherine M","family":"Algie","sequence":"first","affiliation":[{"name":"Western Health; Department of Anaesthesia & Pain Medicine; Gordon Street, Footscray, Locked Bag 2 Footscray Victoria Australia 3011"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert K","family":"Mahar","sequence":"additional","affiliation":[{"name":"The Royal Children's Hospital, The University of Melbourne; Department of Paediatrics; Parkville Australia"},{"name":"Murdoch Childrens Research Institute, The Royal Children's Hospital; Data Science Core; Parkville Victoria Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hannah B","family":"Tan","sequence":"additional","affiliation":[{"name":"The Alfred Hospital; Victorian Adult Burns Service; Commercial Road Prahran Victoria Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Greer","family":"Wilson","sequence":"additional","affiliation":[{"name":"The Royal Melbourne Hospital; Emergency Department; 300 Grattan Street, Parkville Melbourne Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick D","family":"Mahar","sequence":"additional","affiliation":[{"name":"St Vincent's Clinical School, The University of Melbourne; Department of Medicine; Fitzroy Victoria Australia"},{"name":"School of Medicine, Deakin University; Department of Surgery; Geelong Victoria Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jason","family":"Wasiak","sequence":"additional","affiliation":[{"name":"The Epworth Hospital; Department of Radiation Oncology; 89 Bridge Rd Richmond Australia 3121"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2015,11,18]]},"reference":[{"issue":"9","key":"10.1002\/14651858.CD011656.pub2-BIB0001|cit1","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1111\/j.1365-2044.1988.tb05760.x","article-title":"Cricoid pressure and the pressor response to tracheal intubation","volume":"43","author":"Mills","year":"1988","journal-title":"Anaesthesia"},{"issue":"3","key":"10.1002\/14651858.CD011656.pub2-BIB0002|cit2","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/0952-8180(94)00048-9","article-title":"The effect of cricoid pressure application on airway patency","volume":"7","author":"Allman","year":"1995","journal-title":"Journal of Clinical Anesthesia"},{"issue":"5","key":"10.1002\/14651858.CD011656.pub2-BIB0003|cit3","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1093\/bja\/69.5.465","article-title":"Cricoid pressure may prevent insertion of the laryngeal mask airway","volume":"69","author":"Ansermino","year":"1992","journal-title":"British Journal of Anaesthesia"},{"issue":"10","key":"10.1002\/14651858.CD011656.pub2-BIB0004|cit4","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1007\/BF03011906","article-title":"Cricoid pressure impedes positioning and ventilation through the laryngeal mask airway","volume":"43","author":"Aoyama","year":"1996","journal-title":"Canadian Journal of Anaesthesia"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0005|cit5","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1111\/j.1399-6576.2012.02789.x","article-title":"The duration of fibre-optic intubation is increased by cricoid pressure. A randomised double-blind study","volume":"57","author":"Arenkiel","year":"2013","journal-title":"Acta Anaesthesiologica Scandinavica"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0006|cit6","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1093\/bja\/72.1.47","article-title":"Cricoid pressure impedes placement of the laryngeal mask airway and subsequent tracheal intubation through the mask","volume":"72","author":"Asai","year":"1994","journal-title":"British Journal of Anaesthesia"},{"issue":"5","key":"10.1002\/14651858.CD011656.pub2-BIB0007|cit7","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1093\/bja\/74.5.521","article-title":"Cricoid pressure impedes placement of the laryngeal mask airway","volume":"74","author":"Asai","year":"1995","journal-title":"British Journal of Anaesthesia"},{"issue":"6","key":"10.1002\/14651858.CD011656.pub2-BIB0008|cit8","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1093\/bja\/76.6.772","article-title":"Cricoid pressure applied after placement of the laryngeal mask prevents gastric insufflation but inhibits ventilation","volume":"76","author":"Asai","year":"1996","journal-title":"British Journal of Anaesthesia"},{"issue":"2","key":"10.1002\/14651858.CD011656.pub2-BIB0009|cit9","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1093\/bja\/85.2.256","article-title":"Cricoid pressure applied after placement of laryngeal mask impedes subsequent fibreoptic tracheal intubation through mask","volume":"85","author":"Asai","year":"2000","journal-title":"British Journal of Anaesthesia"},{"issue":"9","key":"10.1002\/14651858.CD011656.pub2-BIB0010|cit10","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1046\/j.1365-2044.2002.02706.x","article-title":"Effect of cricoid pressure on the ease of fiberscope-aided tracheal intubation","volume":"57","author":"Asai","year":"2002","journal-title":"Anaesthesia"},{"issue":"2","key":"10.1002\/14651858.CD011656.pub2-BIB0011|cit11","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1093\/bja\/aem159","article-title":"Cricoid pressure prevents placement of the laryngeal tube and laryngeal tube-suction II","volume":"99","author":"Asai","year":"2007","journal-title":"British Journal of Anaesthesia"},{"issue":"2","key":"10.1002\/14651858.CD011656.pub2-BIB0012|cit12","first-page":"20","article-title":"Cricoid pressure effective in aspiration prevention with emergent appendectomy","volume":"13","author":"Dickinson","year":"2014","journal-title":"International Student Journal of Nurse Anesthesia"},{"issue":"1","key":"10.1002\/14651858.CD011656.pub2-BIB0013|cit13","first-page":"46","article-title":"Cricoid pressure in prevention of aspiration","volume":"12","author":"Hamel","year":"2013","journal-title":"International Student Journal of Nurse Anesthesia"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0014|cit14","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1016\/j.resuscitation.2010.02.023","article-title":"Cricoid pressure and laryngeal manipulation in 402 pre-hospital emergency anaesthetics: essential safety measure or a hindrance to rapid safe intubation?","volume":"81","author":"Harris","year":"2010","journal-title":"Resuscitation"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0015|cit15","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1046\/j.1365-2044.1999.00891.x","article-title":"The use of cricoid pressure with the intubating laryngeal mask","volume":"54","author":"Harry","year":"1999","journal-title":"Anaesthesia"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0016|cit16","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1097\/00000542-200102000-00015","article-title":"Effect of cricoid pressure on the success of endotracheal intubation with a lightwand","volume":"94","author":"Hodgson","year":"2001","journal-title":"Anaesthesiology"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0017|cit17","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1046\/j.1365-2044.2000.055002163.x","article-title":"Effect of cricoid pressure on the incidence of nausea and vomiting in the immediate postoperative period","volume":"55","author":"Khan","year":"2000","journal-title":"Anaesthesia"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0018|cit18","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1007\/s12630-011-9543-1","article-title":"Cricoid pressure with the Truview Evo2TM laryngoscope improves the glottic view","volume":"58","author":"Kumar","year":"2011","journal-title":"Canadian Journal of Anaesthesia"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0019|cit19","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1093\/bja\/58.8.925","article-title":"The cricoid-yoke - a device for providing consistent and reproducible cricoid pressure","volume":"58","author":"Lawes","year":"1986","journal-title":"British Journal of Anaesthesia"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0020|cit20","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1111\/j.1365-2044.2007.05019.x","article-title":"The effect of cricoid pressure on intubation facilitated by the gum elastic bougie","volume":"61","author":"McNelis","year":"2007","journal-title":"Anaesthesia"},{"issue":"7","key":"10.1002\/14651858.CD011656.pub2-BIB0021|cit21","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1007\/BF03018715","article-title":"The gum elastic bougie eases tracheal intubation while applying cricoid pressure compared to a stylet","volume":"50","author":"Noguchi","year":"2003","journal-title":"Canadian Journal of Anaesthesia"},{"issue":"2","key":"10.1002\/14651858.CD011656.pub2-BIB0022|cit22","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1177\/0310057X8801600202","article-title":"The prevention of gastric inflation - a neglected benefit of cricoid pressure","volume":"16","author":"Petito","year":"1988","journal-title":"Anaesthesia and Intensive Care"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0023|cit23","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1097\/00000539-200109000-00046","article-title":"The pressor response and airway effects of cricoid pressure during induction of general anaesthesia","volume":"93","author":"Saghaei","year":"2001","journal-title":"Anesthesia and Analgesia"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0024|cit24","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/S0952-8180(01)00241-0","article-title":"A comparison of the Bullard laryngoscope versus the flexible fibreoptic bronchoscope during intubation in patients afforded inline stabilization","volume":"13","author":"Shulman","year":"2001","journal-title":"Journal of Clinical Anesthesia"},{"issue":"6","key":"10.1002\/14651858.CD011656.pub2-BIB0025|cit25","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1007\/BF03017391","article-title":"Cricoid pressure decreases ease of tracheal intubation using fibreoptic laryngoscopy (WuScope SystemTM)","volume":"49","author":"Smith","year":"2002","journal-title":"Canadian Journal of Anaesthesia"},{"issue":"1","key":"10.1002\/14651858.CD011656.pub2-BIB0026|cit26","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1007\/BF03018589","article-title":"The \u201cBURP\u201d maneuver worsens the glottis view when applied in combination with cricoid pressure","volume":"52","author":"Snider","year":"2005","journal-title":"Canadian Journal of Anaesthesia"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0027|cit27","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1097\/00000542-200502000-00012","article-title":"Cricoid pressure does not increased the rate of failed intubation by direct laryngoscopy in adults","volume":"102","author":"Turgeon","year":"2005","journal-title":"Anesthesiology"},{"issue":"3","key":"10.1002\/14651858.CD011656.pub2-BIB0028|cit28","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1213\/ANE.0000000000000068","article-title":"The effectiveness of cricoid pressure for occluding the esophageal entrance in anesthetized and paralyzed patients: an experimental and observational glidescope study","volume":"118","author":"Zeidan","year":"2014","journal-title":"Anesthesia and Analgesia"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0029|cit29","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/1745-6215-13-17","article-title":"Effectiveness of cricoid pressure in preventing gastric aspiration during rapid sequence intubation in the emergency department: study protocol for a randomised controlled trial","volume":"13","author":"Trethewy","year":"2012","journal-title":"Trials"},{"issue":"2","key":"10.1002\/14651858.CD011656.pub2-BIB0030|cit30","first-page":"163","article-title":"Towards evidence-based emergency medicine: best BETs from the Manchester Royal Infirmary. BET 1: Cricoid pressure in emergency rapid sequence induction","volume":"30","author":"Butler","year":"2013","journal-title":"Emergency Medicine Journal"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0031|cit31","unstructured":"Cook T Frerk C (editors) Chapter 19: Aspiration of gastric contents and blood. In: NAP4: 4th National Audit Project of The Royal College of Anaesthetists and The Difficult Airway Society: Major complications of airway management in the United Kingdom [March 2011]. The Royal College of Anaesthetists, 2011 Available from http:\/\/www.rcoa.ac.uk\/system\/files\/CSQ-NAP4-Full.pdf (accessed 4 July 2015)"},{"issue":"3","key":"10.1002\/14651858.CD011656.pub2-BIB0032|cit32","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/0197-2456(86)90046-2","article-title":"Meta-analysis in clinical trials","volume":"7","author":"DerSimonian","year":"1986","journal-title":"Controlled Clinical Trials"},{"issue":"8746","key":"10.1002\/14651858.CD011656.pub2-BIB0033|cit33","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1016\/0140-6736(91)90201-Y","article-title":"Publication bias in clinical research","volume":"337","author":"Easterbrook","year":"1991","journal-title":"Lancet"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0034|cit34","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1136\/bmj.315.7109.629","article-title":"Bias in meta-analysis detected by a simple, graphical test","volume":"315","author":"Egger","year":"1997","journal-title":"BMJ (Clinical Research Ed.)"},{"issue":"5","key":"10.1002\/14651858.CD011656.pub2-BIB0035|cit35","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1213\/ANE.0b013e3181d5ae47","article-title":"Rapid sequence induction and intubation: current controversy","volume":"110","author":"El-Orbany","year":"2010","journal-title":"Anesthesia and Analgesia"},{"issue":"9","key":"10.1002\/14651858.CD011656.pub2-BIB0036|cit36","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1177\/175045890701700903","article-title":"The efficacy of cricoid pressure in preventing gastro-oesophageal reflux in rapid sequence induction of anaesthesia","volume":"17","author":"Ewart","year":"2007","journal-title":"Journal of Perioperative Practice"},{"issue":"5","key":"10.1002\/14651858.CD011656.pub2-BIB0037|cit37","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1111\/j.1365-2044.2004.03682.x","article-title":"The effect of mechanically-induced cricoid force on lower oesophageal sphincter pressure in anaesthetized patients","volume":"59","author":"Garrard","year":"2004","journal-title":"Anaesthesia"},{"issue":"3","key":"10.1002\/14651858.CD011656.pub2-BIB0038|cit38","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1213\/00000539-199203000-00022","article-title":"The Sellick maneuver causing complete airway obstruction","volume":"74","author":"Georgescu","year":"1992","journal-title":"Anesthesia and Analgesia"},{"issue":"1","key":"10.1002\/14651858.CD011656.pub2-BIB0039|cit39","doi-asserted-by":"crossref","first-page":"55","DOI":"10.2307\/2530643","article-title":"Estimation of a common effect parameter from sparse follow-up data","volume":"41","author":"Greenland","year":"1985","journal-title":"Biometrics"},{"issue":"7651","key":"10.1002\/14651858.CD011656.pub2-BIB0040|cit40","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1136\/bmj.39490.551019.BE","article-title":"What is \"quality of evidence\" and why is it important to clinicians?","volume":"336","author":"Guyatt","year":"2008","journal-title":"BMJ (Clinical Research Ed.)"},{"issue":"3","key":"10.1002\/14651858.CD011656.pub2-BIB0041|cit41","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1046\/j.1365-2044.2000.01205.x","article-title":"Airway obstruction with cricoid pressure","volume":"55","author":"Hartsilver","year":"2000","journal-title":"Anesthesia"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0042|cit42","unstructured":"Higgins JPT, Green S (editors). Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011] The Cochrane Collaboration, 2011. Available from www.cochrane-handbook.org"},{"issue":"1","key":"10.1002\/14651858.CD011656.pub2-BIB0043|cit43","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1046\/j.1365-2044.1999.00642.x","article-title":"Aspiration during anaesthesia: a review of 133 cases from the Australian Anaesthetic Incident Monitoring Study (AIMS)","volume":"54","author":"Kluger","year":"1999","journal-title":"Anaesthesia"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0044|cit44","doi-asserted-by":"crossref","first-page":"e4","DOI":"10.1136\/qshc.2002.004259","article-title":"Crisis management during anaesthesia: regurgitation, vomiting and aspiration","volume":"14","author":"Kluger","year":"2005","journal-title":"Quality and Safety in Health Care"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0045|cit45","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1016\/j.emc.2008.10.002","article-title":"Challenges and advances in intubation: rapid sequence intubation","volume":"26","author":"Mace","year":"2008","journal-title":"Emergency Medicine Clinics of North America"},{"issue":"4","key":"10.1002\/14651858.CD011656.pub2-BIB0046|cit46","doi-asserted-by":"crossref","first-page":"264","DOI":"10.7326\/0003-4819-151-4-200908180-00135","article-title":"Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement","volume":"151","author":"Moher","year":"2009","journal-title":"Annals of Internal Medicine"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0047|cit47","first-page":"286","article-title":"Chapter 15: Adjuncts to anaesthesia","volume-title":"Clinical Anaesthesiology","author":"Morgan","year":"2006"},{"issue":"3","key":"10.1002\/14651858.CD011656.pub2-BIB0048|cit48","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1046\/j.1365-2044.2000.01207.x","article-title":"The effect of cricoid pressure on the cricoid cartilage and vocal cords: an endoscopic in anaesthetised patients","volume":"55","author":"Palmer","year":"2000","journal-title":"Anesthesia"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0049|cit49","unstructured":"The Nordic Cochrane Centre, The Cochrane Collaboration Review Manager (RevMan) 2014"},{"issue":"2","key":"10.1002\/14651858.CD011656.pub2-BIB0050|cit50","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1097\/00000542-199502000-00007","article-title":"Death and other complications of emergency airway management in critically ill adults: a prospective investigation of 297 tracheal intubations","volume":"82","author":"Schwartz","year":"1995","journal-title":"Anesthesiology"},{"issue":"7199","key":"10.1002\/14651858.CD011656.pub2-BIB0051|cit51","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1016\/S0140-6736(61)92485-0","article-title":"Cricoid pressure to control regurgitation of stomach contents during induction of anaesthesia","volume":"278","author":"Sellick","year":"1961","journal-title":"Lancet"},{"issue":"5","key":"10.1002\/14651858.CD011656.pub2-BIB0052|cit52","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/0952-8180(91)90185-P","article-title":"Airway obstruction following application of cricoid pressure","volume":"3","author":"Shorten","year":"1991","journal-title":"Journal of Clinical Anesthesia"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0053|cit53","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1097\/00045413-200105000-00004","article-title":"Rapid-sequence intubation in adults: indications and concerns","volume":"8","author":"Smith","year":"2001","journal-title":"Clinical Pulmonary Medicine"},{"issue":"1","key":"10.1002\/14651858.CD011656.pub2-BIB0054|cit54","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1097\/00000542-200307000-00013","article-title":"Cricoid pressure displaces the esophagus: an observational study using magnetic resonance imaging","volume":"99","author":"Smith","year":"2003","journal-title":"Anesthesiology"},{"key":"10.1002\/14651858.CD011656.pub2-BIB0055|cit55","doi-asserted-by":"crossref","first-page":"1459","DOI":"10.1136\/bmj.327.7429.1459","article-title":"Parachute use to prevent death and major trauma related to gravitational challenge: systematic review of randomised controlled trials","volume":"327","author":"Smith","year":"2003","journal-title":"BMJ"},{"issue":"1","key":"10.1002\/14651858.CD011656.pub2-BIB0056|cit56","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/00000542-199701000-00003","article-title":"Cricoid cartilage pressure decreases lower oesophageal sphincter tone","volume":"86","author":"Tournadre","year":"1997","journal-title":"Anesthesiology"},{"issue":"6","key":"10.1002\/14651858.CD011656.pub2-BIB0057|cit57","first-page":"12","article-title":"A new pepsin assay to detect pulmonary aspiration of gastric contents among newly intubated patient","volume":"22","author":"Ufberg","year":"2004","journal-title":"American Journal of Emergency Medicine"},{"issue":"5","key":"10.1002\/14651858.CD011656.pub2-BIB0058|cit58","doi-asserted-by":"crossref","first-page":"101","DOI":"10.3310\/hta3050","article-title":"Methods for evaluating area-wide and organization based interventions in health and health care: a systematic review","volume":"3","author":"Ukoumunne","year":"1999","journal-title":"Health Technology Assessment"},{"issue":"1","key":"10.1002\/14651858.CD011656.pub2-BIB0059|cit59","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1046\/j.1365-2044.1999.00756.x","article-title":"Safe use of cricoid pressure","volume":"54","author":"Vanner","year":"1999","journal-title":"Anesthesia"},{"issue":"10","key":"10.1002\/14651858.CD011656.pub2-BIB0060|cit60","doi-asserted-by":"crossref","first-page":"1028","DOI":"10.1046\/j.1365-2044.2000.01727-8.x","article-title":"Auditing the application of cricoid pressure","volume":"55","author":"Walton","year":"2000","journal-title":"Anesthesia"},{"issue":"4","key":"10.1002\/14651858.CD011656.pub2-BIB0061|cit61","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD011656","article-title":"Effectiveness and risks of cricoid pressure during rapid sequence intubation","author":"Algie","year":"2015","journal-title":"Cochrane Database of Systematic Reviews"}],"container-title":["Cochrane Database of Systematic Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full\/10.1002\/14651858.CD011656.pub2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,30]],"date-time":"2022-07-30T08:47:43Z","timestamp":1659170863000},"score":1,"resource":{"primary":{"URL":"http:\/\/doi.wiley.com\/10.1002\/14651858.CD011656.pub2"}},"subtitle":[],"editor":[{"name":"Cochrane Anaesthesia Group","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2015,11,18]]},"references-count":61,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2015,11]]}},"URL":"https:\/\/doi.org\/10.1002\/14651858.cd011656.pub2","relation":{},"ISSN":["1465-1858"],"issn-type":[{"value":"1465-1858","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,11,18]]}}}