{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T16:37:48Z","timestamp":1794242268844,"version":"4.9.0"},"reference-count":95,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2020,1,20]],"date-time":"2020-01-20T00:00:00Z","timestamp":1579478400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004189","name":"Max-Planck-Gesellschaft","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004189","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["advanced.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Advanced Intelligent Systems"],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:sec><jats:label\/><jats:p>Magnetic resonance imaging (MRI) system\u2013driven medical robotics is an emerging field that aims to use clinical MRI systems not only for medical imaging but also for actuation, localization, and control of medical robots. Submillimeter scale resolution of MR images for soft tissues combined with the electromagnetic gradient coil\u2013based magnetic actuation available inside MR scanners can enable theranostic applications of medical robots for precise image\u2010guided minimally invasive interventions. MRI\u2010driven robotics typically does not introduce new MRI instrumentation for actuation but instead focuses on converting already available instrumentation for robotic purposes. To use the advantages of this technology, various medical devices such as untethered mobile magnetic robots and tethered active catheters have been designed to be powered magnetically inside MRI systems. Herein, the state\u2010of\u2010the\u2010art progress, challenges, and future directions of MRI\u2010driven medical robotic systems are reviewed.<\/jats:p><\/jats:sec>","DOI":"10.1002\/aisy.201900110","type":"journal-article","created":{"date-parts":[[2019,11,19]],"date-time":"2019-11-19T13:55:51Z","timestamp":1574171751000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":74,"title":["Magnetic Resonance Imaging System\u2013Driven Medical Robotics"],"prefix":"10.1002","volume":"2","author":[{"given":"Onder","family":"Erin","sequence":"first","affiliation":[{"name":"Physical Intelligence Department Max Planck Institute for Intelligent Systems  Stuttgart 70569 Germany"},{"name":"Mechanical Engineering Department Carnegie Mellon University  Pittsburgh PA 15213 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mustafa","family":"Boyvat","sequence":"additional","affiliation":[{"name":"Physical Intelligence Department Max Planck Institute for Intelligent Systems  Stuttgart 70569 Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mehmet Efe","family":"Tiryaki","sequence":"additional","affiliation":[{"name":"Physical Intelligence Department Max Planck Institute for Intelligent Systems  Stuttgart 70569 Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Phelan","sequence":"additional","affiliation":[{"name":"Physical Intelligence Department Max Planck Institute for Intelligent Systems  Stuttgart 70569 Germany"},{"name":"Mechanical Engineering Department Carnegie Mellon University  Pittsburgh PA 15213 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8249-3854","authenticated-orcid":false,"given":"Metin","family":"Sitti","sequence":"additional","affiliation":[{"name":"Physical Intelligence Department Max Planck Institute for Intelligent Systems  Stuttgart 70569 Germany"},{"name":"Mechanical Engineering Department Carnegie Mellon University  Pittsburgh PA 15213 USA"},{"name":"School of Engineering and School of Medicine Ko\u00e7 University  Istanbul 34450 Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2020,1,20]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1126\/scirobotics.aar7650"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2013.01.487"},{"key":"e_1_2_10_4_1","first-page":"2017","volume-title":"Health at a Glance","author":"OECD","year":"2017"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2005.862570"},{"key":"e_1_2_10_6_1","doi-asserted-by":"crossref","unstructured":"A.Becker O.Felfoul P. E.Dupont inIEEE\/RSJ Int. Conf. Intelligent Robots and Systems IEEE Chicago IL2014 p.2017.","DOI":"10.1109\/IROS.2014.6942831"},{"key":"e_1_2_10_7_1","doi-asserted-by":"crossref","unstructured":"A. T.Becker O.Felfoul P. E.Dupont inIEEE Int. Conf. Robotics and Automation IEEE Seattle WA2015 p.1184.","DOI":"10.1109\/ICRA.2015.7139341"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1109\/TRO.2015.2407795"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1177\/0278364913500362"},{"key":"e_1_2_10_10_1","doi-asserted-by":"crossref","unstructured":"P.Vartholomeos L.Qin P. E.Dupont inIEEE\/RSJ Int. Conf. Intelligent Robots and Systems IEEE San Francisco CA2011 p.4508.","DOI":"10.1109\/IROS.2011.6094962"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10544-011-9594-7"},{"key":"e_1_2_10_12_1","first-page":"403","volume":"3","author":"Leclerc J.","year":"2018","journal-title":"IEEE Rob. Autom. Lett."},{"key":"e_1_2_10_13_1","doi-asserted-by":"crossref","unstructured":"L.Arcese M.Fruchard A.Ferreira inIEEE\/RSJ Int. Conf. Intelligent Robots and Systems IEEE St. Louis MO2009 p.534.","DOI":"10.1109\/IROS.2009.5354600"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1109\/TRO.2014.2300591"},{"key":"e_1_2_10_15_1","doi-asserted-by":"crossref","unstructured":"O.Erin J.Giltinan L.Tsai M.Sitti inIEEE Int. Conf. Robotics and Automation IEEE Singapore2017 p.3404.","DOI":"10.1109\/ICRA.2017.7989387"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1038\/srep33567"},{"key":"e_1_2_10_17_1","doi-asserted-by":"crossref","unstructured":"D.Folio C.Dahmen T.Wortmann M. A.Zeeshan K.Shou S.Pane B. J.Nelson A.Ferreira S.Fatikow inIEEE\/RSJ Int. Conf. Intelligent Robots and Systems IEEE San Francisco CA2011 p.1297.","DOI":"10.1109\/IROS.2011.6094975"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3622599"},{"key":"e_1_2_10_19_1","doi-asserted-by":"crossref","unstructured":"V.Lalande F. P.Gosselin S.Martel inIEEE\/ASME Int. Conf. Advanced Intelligent Mechatronics IEEE Montreal2010 p.103.","DOI":"10.1109\/AIM.2010.5695914"},{"key":"e_1_2_10_20_1","doi-asserted-by":"crossref","unstructured":"V.Lalande F. P.Gosselin S.Martel inInt. Conf. IEEE Engineering in Medicine and Biology Society IEEE Buenos Aires2010 p.1874.","DOI":"10.1109\/IEMBS.2010.5627150"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.4941925"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22279"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2009.08.005"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2010.12.059"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.10325"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2750963"},{"key":"e_1_2_10_27_1","doi-asserted-by":"crossref","unstructured":"P.Vartholomeos M. R.Akhavan-Sharif P. E.Dupont inIEEE Int. Conf. Robotics and Automation IEEE Saint Paul MN2012 p.1927.","DOI":"10.1109\/ICRA.2012.6225330"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1177\/0278364915583539"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.4874306"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1038\/nature25443"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.1608193113"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1039\/C4LC00004H"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1080\/15599612.2016.1166305"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.2713229"},{"key":"e_1_2_10_35_1","doi-asserted-by":"crossref","unstructured":"M.Latulippe S.Martel inIEEE RAS\/EMBS Int. Conf. Biomedical Robotics and Biomechatronics IEEE S\u00e3o Paulo2014 p.320.","DOI":"10.1109\/BIOROB.2014.6913796"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1109\/TRO.2015.2489518"},{"key":"e_1_2_10_37_1","doi-asserted-by":"crossref","unstructured":"A.Friedman A.Liberzon G.K\u00f3sa inIEEE Int. Conf. Robotics and Automation IEEE Seattle WA2015 p.4736.","DOI":"10.1109\/ICRA.2015.7139857"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20202"},{"key":"e_1_2_10_39_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21239"},{"key":"e_1_2_10_40_1","doi-asserted-by":"publisher","DOI":"10.1038\/srep12842"},{"key":"e_1_2_10_41_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910370116"},{"key":"e_1_2_10_42_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-2594(199903)41:3<636::AID-MRM30>3.0.CO;2-A"},{"key":"e_1_2_10_43_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880080137"},{"key":"e_1_2_10_44_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910370614"},{"key":"e_1_2_10_45_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF01759775"},{"key":"e_1_2_10_46_1","first-page":"89","volume":"60","author":"Kaiser M.","year":"2015","journal-title":"Biomed. Eng.\/Biomed. Tech."},{"key":"e_1_2_10_47_1","author":"Jordan C. D.","year":"2019","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"e_1_2_10_48_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41551-018-0309-8"},{"key":"e_1_2_10_49_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2014.03.007"},{"key":"e_1_2_10_50_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.snb.2009.03.026"},{"key":"e_1_2_10_51_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21419"},{"key":"e_1_2_10_52_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20347"},{"key":"e_1_2_10_53_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.10307"},{"key":"e_1_2_10_54_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910360326"},{"key":"e_1_2_10_55_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20041"},{"key":"e_1_2_10_56_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910380214"},{"key":"e_1_2_10_57_1","doi-asserted-by":"publisher","DOI":"10.1109\/42.736037"},{"key":"e_1_2_10_58_1","doi-asserted-by":"crossref","unstructured":"N.Olamaei F.Cheriet G.Beaudoin S.Martel inInt. Conf. IEEE Engineering in Medicine and Biology Society IEEE Buenos Aires2010 p.4355.","DOI":"10.1109\/IEMBS.2010.5626222"},{"key":"e_1_2_10_59_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2007.897375"},{"key":"e_1_2_10_60_1","doi-asserted-by":"publisher","DOI":"10.1109\/TRO.2010.2073030"},{"key":"e_1_2_10_61_1","doi-asserted-by":"crossref","unstructured":"D.Son M. D.Dogan M.Sitti inIEEE Int. Conf. Robotics and Automation IEEE Singapore2017 p.1132.","DOI":"10.1109\/ICRA.2017.7989135"},{"key":"e_1_2_10_62_1","doi-asserted-by":"publisher","DOI":"10.1002\/smll.201303538"},{"key":"e_1_2_10_63_1","doi-asserted-by":"publisher","DOI":"10.1177\/0278364909353351"},{"key":"e_1_2_10_64_1","doi-asserted-by":"publisher","DOI":"10.1109\/TRO.2007.910775"},{"key":"e_1_2_10_65_1","author":"Son D.","year":"2019","journal-title":"Soft Rob."},{"key":"e_1_2_10_66_1","doi-asserted-by":"publisher","DOI":"10.1109\/TRO.2011.2163861"},{"key":"e_1_2_10_67_1","doi-asserted-by":"publisher","DOI":"10.1177\/0278364909341413"},{"key":"e_1_2_10_68_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41586-018-0185-0"},{"key":"e_1_2_10_69_1","doi-asserted-by":"publisher","DOI":"10.1126\/scirobotics.aax7329"},{"key":"e_1_2_10_70_1","doi-asserted-by":"publisher","DOI":"10.1109\/TRO.2019.2934712"},{"key":"e_1_2_10_71_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2015.2510743"},{"key":"e_1_2_10_72_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.13298"},{"key":"e_1_2_10_73_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2015142648"},{"key":"e_1_2_10_74_1","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3530"},{"key":"e_1_2_10_75_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2017.2704526"},{"key":"e_1_2_10_76_1","doi-asserted-by":"crossref","unstructured":"T.Greigarn R.Jackson T.Liu M. C.\u00c7avu\u015fo\u011flu inIEEE Int. Conf. Robotics and Automation IEEE Singapore2017 p.3600.","DOI":"10.1109\/ICRA.2017.7989414"},{"key":"e_1_2_10_77_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.4036095"},{"key":"e_1_2_10_78_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10334-010-0214-y"},{"key":"e_1_2_10_79_1","doi-asserted-by":"publisher","DOI":"10.1002\/cmr.a.20163"},{"key":"e_1_2_10_80_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21638"},{"key":"e_1_2_10_81_1","doi-asserted-by":"crossref","unstructured":"A.Chanu E.Aboussouan S.Tamaz S.Martel inInt. Conf. IEEE Engineering in Medicine and Biology Society IEEE New York2006 p.1746.","DOI":"10.1109\/IEMBS.2006.260577"},{"key":"e_1_2_10_82_1","doi-asserted-by":"publisher","DOI":"10.1097\/HP.0000000000000654"},{"key":"e_1_2_10_83_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25761"},{"key":"e_1_2_10_84_1","doi-asserted-by":"publisher","DOI":"10.1097\/HP.0b013e3181aff9eb"},{"key":"e_1_2_10_85_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004032-200408000-00008"},{"key":"e_1_2_10_86_1","volume-title":"Guidance for Industry and Food and Drug Administration Staff","author":"FDA","year":"2016"},{"key":"e_1_2_10_87_1","volume-title":"Clinical Investigation of Medical Devices for Human Subjects: Good Clinical Practice","author":"ISO","year":"2011"},{"key":"e_1_2_10_88_1","doi-asserted-by":"publisher","DOI":"10.1126\/scirobotics.aam8638"},{"key":"e_1_2_10_89_1","doi-asserted-by":"publisher","DOI":"10.1038\/nm1700"},{"key":"e_1_2_10_90_1","doi-asserted-by":"publisher","DOI":"10.1039\/C4CS00345D"},{"key":"e_1_2_10_91_1","doi-asserted-by":"publisher","DOI":"10.1146\/annurev.med.60.041707.170303"},{"key":"e_1_2_10_92_1","doi-asserted-by":"publisher","DOI":"10.1002\/adma.201605529"},{"key":"e_1_2_10_93_1","doi-asserted-by":"publisher","DOI":"10.1109\/JPROC.2014.2385105"},{"key":"e_1_2_10_94_1","doi-asserted-by":"publisher","DOI":"10.1039\/C7LC00064B"},{"key":"e_1_2_10_95_1","unstructured":"J.-B.Mathieu S.Martel L. H.Yahia G.Soulez G.Beaudoin inInt. Conf. IEEE Engineering in Medicine and Biology Society IEEE Cancun2003 p.3419."},{"key":"e_1_2_10_96_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4861823"}],"container-title":["Advanced Intelligent Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/aisy.201900110","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/aisy.201900110","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/advanced.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/aisy.201900110","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,7]],"date-time":"2025-10-07T23:56:27Z","timestamp":1759881387000},"score":1,"resource":{"primary":{"URL":"https:\/\/advanced.onlinelibrary.wiley.com\/doi\/10.1002\/aisy.201900110"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,20]]},"references-count":95,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["10.1002\/aisy.201900110"],"URL":"https:\/\/doi.org\/10.1002\/aisy.201900110","archive":["Portico"],"relation":{},"ISSN":["2640-4567","2640-4567"],"issn-type":[{"value":"2640-4567","type":"print"},{"value":"2640-4567","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,20]]},"assertion":[{"value":"2019-09-18","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-01-20","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"1900110"}}