{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T12:11:45Z","timestamp":1780056705529,"version":"3.54.0"},"reference-count":25,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2024,12,12]],"date-time":"2024-12-12T00:00:00Z","timestamp":1733961600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["52307086"],"award-info":[{"award-number":["52307086"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Circuit Theory &amp; Apps"],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p>With the expansion of hybrid AC\/DC microgrids (MGs), the AC and DC subgrids should be able to maintain interconnection through interlinking converter (IC) under short\u2010circuit faults to avoid the system instability caused by power mutation. Conventional IC control methods have given insights into the current restraining between two subgrids but neglect the transient voltage\/frequency support requirement, especially under islanded operation mode. This paper proposes a grid\u2010forming IC control with fault\u2010ride\u2010through (FRT) capability. An <jats:italic>f<\/jats:italic><jats:sub>n<\/jats:sub>\u2010<jats:italic>P<\/jats:italic><jats:sub>ic<\/jats:sub>\u2010<jats:italic>V<\/jats:italic><jats:sub>dc<\/jats:sub> control architecture is presented to regulate power exchanges among AC and DC subgrids with solid AC bus voltage supports under the premise of DC voltage stable. Additionally, the Lyapunov large disturbance stability equation is established, and the safe operating boundaries of key parameters are described based on the Takagi\u2013Sugeno (TS) model criterion. It is revealed that within certain range, the proper DC voltage feedback control parameters in IC could enhance the system stability and the power support capability of DC subgrid to the AC side. Finally, comparative case studies are conducted to validate effectiveness of the proposed control strategy.<\/jats:p>","DOI":"10.1002\/cta.4394","type":"journal-article","created":{"date-parts":[[2024,12,12]],"date-time":"2024-12-12T23:25:21Z","timestamp":1734045921000},"page":"5410-5421","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Grid\u2010Forming Interlinking Converter With Fault\u2010Ride\u2010Through Capability in Islanded Hybrid AC\/DC Microgrids"],"prefix":"10.1002","volume":"53","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0286-4350","authenticated-orcid":false,"given":"Xia","family":"Shen","sequence":"first","affiliation":[{"name":"College of Electrical Engineering Southeast University  Nanjing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7674-627X","authenticated-orcid":false,"given":"Chao","family":"Shen","sequence":"additional","affiliation":[{"name":"College of Electrical Engineering Southeast University  Nanjing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feng","family":"Zhao","sequence":"additional","affiliation":[{"name":"Hunan University  Changsha China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wen","family":"Huang","sequence":"additional","affiliation":[{"name":"Hunan University  Changsha China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,12,12]]},"reference":[{"key":"e_1_2_8_2_1","unstructured":"\u201cIEEE Standard for interconnection and interoperability of distributed energy resources with associated electric power systems interfaces \u201d IEEE Std 1547\u20102018 \u2013 Redline (2018):1\u2013227."},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1109\/PESGM.2017.8274583"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1109\/JESTPE.2020.2983726"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2021.3073943"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1109\/MPEL.2019.2925298"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1049\/rpg2.12028"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1109\/ISGT-Europe54678.2022.9960394"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1109\/ISGT.2019.8791661"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2021.3071323"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2020.106616"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2020.3001802"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2022.3230787"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.egyr.2024.06.001"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2021.3078839"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2020.105927"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2023.3343327"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2021.107298"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1109\/JESTPE.2020.3017713"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2022.3191132"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1109\/JESTPE.2017.2740424"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2018.2864208"},{"issue":"2","key":"e_1_2_8_23_1","first-page":"593","article-title":"Transient Stability Analysis and Design of VSGs With Different DC\u2010Link Voltage Controllers","volume":"10","author":"Shen C.","year":"2024","journal-title":"CSEE Journal of Power and Energy Systems"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2020.2965152"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2017.2752146"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2011.2170202"}],"container-title":["International Journal of Circuit Theory and Applications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/cta.4394","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T09:53:10Z","timestamp":1757325190000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/cta.4394"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,12]]},"references-count":25,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["10.1002\/cta.4394"],"URL":"https:\/\/doi.org\/10.1002\/cta.4394","archive":["Portico"],"relation":{},"ISSN":["0098-9886","1097-007X"],"issn-type":[{"value":"0098-9886","type":"print"},{"value":"1097-007X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,12]]},"assertion":[{"value":"2024-10-18","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-11-24","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-12-12","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}