{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T18:30:18Z","timestamp":1777401018909,"version":"3.51.4"},"reference-count":21,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2025,9,15]],"date-time":"2025-09-15T00:00:00Z","timestamp":1757894400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2025,9,15]],"date-time":"2025-09-15T00:00:00Z","timestamp":1757894400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Circuit Theory &amp; Apps"],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>Inverter\u2010interfaced distributed generation (IIDG) unit requires special attention to keep reliable operation under short\u2010circuit fault condition. However, when the fault is clear, overvoltage and overcurrent issues of the IIDG unit may occur and even trigger its shutdown. To tackle these issues, an enhanced four\u2010state protection strategy for the IIDG unit is proposed. Firstly, the model of the IIDG unit under normal and short\u2010circuit fault conditions is analyzed. Secondly, based on the analyzed model, an enhanced four\u2010state protection strategy, which contains normal state, hardware current\u2010limiting state, software current\u2010limiting state, and recovery state, is presented, respectively. Moreover, the parameter design of the proposed protection strategy is also given comprehensively. Thanks to the enhanced four\u2010state protection strategy, overvoltage and overcurrent issues of the IIDG unit under short\u2010circuit fault condition are addressed. What is more, the proposed protection strategy can not only keep satisfactory dynamic performance under short\u2010circuit fault condition, but also improve the reliability of the IIDG unit. Finally, simulation and experimental results in a 5\u2010kVA IIDG unit verify the correctness and feasibility of the proposed protection strategy.<\/jats:p>","DOI":"10.1002\/cta.70117","type":"journal-article","created":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T06:57:02Z","timestamp":1758005822000},"page":"2626-2638","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["An Enhanced Four\u2010State Protection Strategy for Inverter\u2010Interfaced Distributed Generation Unit Under Short\u2010Circuit Fault Condition"],"prefix":"10.1002","volume":"54","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4685-3992","authenticated-orcid":false,"given":"Weibiao","family":"Wu","sequence":"first","affiliation":[{"name":"School of Electronic and Electrical Engineering Wuhan Textile University  Wuhan Hubei China"},{"name":"Hubei Key Laboratory of Digital Textile Equipment Wuhan Textile University  Wuhan Hubei China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1075-3095","authenticated-orcid":false,"given":"Ming","family":"Zhang","sequence":"additional","affiliation":[{"name":"School of Electronic and Electrical Engineering Wuhan Textile University  Wuhan Hubei China"},{"name":"Hubei Key Laboratory of Digital Textile Equipment Wuhan Textile University  Wuhan Hubei China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xinmin","family":"Liu","sequence":"additional","affiliation":[{"name":"School of Electrical and Electronic Engineering Huazhong University of Science and Technology  Wuhan Hubei China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenqiang","family":"Zhu","sequence":"additional","affiliation":[{"name":"School of Electronic and Electrical Engineering Wuhan Textile University  Wuhan Hubei China"},{"name":"Hubei Key Laboratory of Digital Textile Equipment Wuhan Textile University  Wuhan Hubei China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gujing","family":"Han","sequence":"additional","affiliation":[{"name":"School of Electronic and Electrical Engineering Wuhan Textile University  Wuhan Hubei China"},{"name":"Hubei Key Laboratory of Digital Textile Equipment Wuhan Textile University  Wuhan Hubei China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,9,15]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2022.3204825"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2025.3540446"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2021.3133843"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1109\/PSCE.2004.1397672"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1109\/TII.2012.2187913"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2018.2879191"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2013.2279162"},{"issue":"9","key":"e_1_2_9_9_1","first-page":"7684","article-title":"A Novel Protection Scheme for Inverter\u2010Interfaced Microgrid (IIM) Operated in Islanded Mode","volume":"33","author":"Chen Z.","year":"2018","journal-title":"IEEE Transactions on Power Electronics"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2020.3006791"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2017.2717388"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2019.2898165"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2024.3371403"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2024.3447755"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2024.3436639"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2023.3319476"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2015.2458960"},{"issue":"6","key":"e_1_2_9_18_1","first-page":"3557","article-title":"Sinusoidal Voltage Shaping of Inverter\u2010Equipped Stand\u2010Alone Generating Units","volume":"62","author":"Lidozzi A.","year":"2015","journal-title":"IEEE Transactions on Industrial Electronics"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2019.2929144"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2021.3094490"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2010.2066290"},{"key":"e_1_2_9_22_1","series-title":"Lectures on Power Electronics","first-page":"81","volume-title":"Digital Control in Power Electronics","author":"Suso B.","year":"2006"}],"container-title":["International Journal of Circuit Theory and Applications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/cta.70117","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/cta.70117","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/cta.70117","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T10:20:26Z","timestamp":1777371626000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/cta.70117"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,15]]},"references-count":21,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["10.1002\/cta.70117"],"URL":"https:\/\/doi.org\/10.1002\/cta.70117","archive":["Portico"],"relation":{},"ISSN":["0098-9886","1097-007X"],"issn-type":[{"value":"0098-9886","type":"print"},{"value":"1097-007X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,15]]},"assertion":[{"value":"2025-04-29","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-08-13","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-15","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}