{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:16:17Z","timestamp":1787019377224,"version":"build-2736575974"},"reference-count":20,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T00:00:00Z","timestamp":1757980800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T00:00:00Z","timestamp":1757980800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Circuit Theory &amp; Apps"],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>This paper presents a novel peak power control strategy for LLC resonant converters, targeting renewable energy\u2010based hydrogen production systems. Unlike conventional charge control methods, PPC regulates the peak half\u2010cycle charge by adjusting the resonant capacitor's negative peak voltage and a feedback\u2010defined voltage increment, enabling fast and accurate power control. The proposed method features first\u2010order dynamic behavior with high bandwidth and phase margin, leading to improved stability and transient performance. A fully digital implementation based on a TMS320F280049C controller is developed, and a 110\u2009V\/24\u2009V, 240\u2009W prototype is built for experimental validation. Test results show that PPC achieves faster dynamic response and lower voltage deviation compared to time\u2010shift control and hybrid hysteresis control, while also enhancing robustness under overcurrent and short\u2010circuit conditions. These advantages make PPC a promising control solution for high\u2010efficiency and stable power conversion in hydrogen energy applications.<\/jats:p>","DOI":"10.1002\/cta.70141","type":"journal-article","created":{"date-parts":[[2025,9,17]],"date-time":"2025-09-17T04:10:08Z","timestamp":1758082208000},"page":"2639-2651","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["A Charge Control Strategy With Digital Implementation for LLC Resonant Converters"],"prefix":"10.1002","volume":"54","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9870-373X","authenticated-orcid":false,"given":"Yu","family":"Tang","sequence":"first","affiliation":[{"name":"Hebei University of Technology State Key Laboratory of Reliability and Intelligence of Electrical Equipment Hebei University of Technology  Tianjin China"},{"name":"Hebei University of Technology School of Electrical Engineering Hebei University of Technology  Tianjin China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-4594-3384","authenticated-orcid":false,"given":"Feilong","family":"Li","sequence":"additional","affiliation":[{"name":"Hebei University of Technology State Key Laboratory of Reliability and Intelligence of Electrical Equipment Hebei University of Technology  Tianjin China"},{"name":"Hebei University of Technology School of Electrical Engineering Hebei University of Technology  Tianjin China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heng","family":"Liu","sequence":"additional","affiliation":[{"name":"Hebei University of Technology State Key Laboratory of Reliability and Intelligence of Electrical Equipment Hebei University of Technology  Tianjin China"},{"name":"Hebei University of Technology School of Electrical Engineering Hebei University of Technology  Tianjin China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,9,16]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2023.3282923"},{"key":"e_1_2_10_3_1","doi-asserted-by":"crossref","unstructured":"C.Tang C.Zhang L.Zhang F.Wang andX.Zhao \u201cA High\u2010Power Converter for Electrolytic Hydrogen Production Based on DC Microgrid \u201d (2024):622\u2013627.","DOI":"10.1109\/ISESC63657.2024.10785276"},{"key":"e_1_2_10_4_1","doi-asserted-by":"crossref","unstructured":"B.Yang F.Lee A.Zhang andG.Huang \u201cLLC Resonant Converter for Front End DC\/DC Conversion \u201d in 2 (2002):1108\u20131112 vol.2","DOI":"10.1109\/APEC.2002.989382"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2024.3515155"},{"key":"e_1_2_10_6_1","doi-asserted-by":"crossref","unstructured":"N.Yildiran \u201cDesign Methodology and Implementation of Half\u2010Bridge LLC Resonant Converter \u201d (2020):1\u20136","DOI":"10.1109\/ICECCE49384.2020.9179322"},{"key":"e_1_2_10_7_1","doi-asserted-by":"crossref","unstructured":"S.Tian F. C.Lee andQ.Li \u201cEquivalent Circuit Modeling of LLC Resonant Converter \u201d in (2016):1608\u20131615","DOI":"10.1109\/APEC.2016.7468082"},{"key":"e_1_2_10_8_1","doi-asserted-by":"crossref","unstructured":"M.Farooq F.Gurara M.Khatua D.Shahzad S.Pervaiz andK. K.Afridi \u201cControl Techniques for a Current\u2010Mode\u2010Controlled Merged\u2010Energy\u2010Buffer\u2010Based Two\u2010Stage Electrolytic\u2010Free Offline LED Driver \u201d in (2021):2251\u20132257","DOI":"10.1109\/ECCE47101.2021.9595487"},{"key":"e_1_2_10_9_1","doi-asserted-by":"crossref","unstructured":"Y. H.HsiehandF. C.Lee \u201cAccurate Small\u2010Signal Model for LLC Resonant Converters \u201d in (2019):660\u2013665","DOI":"10.1109\/ECCE.2019.8913021"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2024.3450712"},{"key":"e_1_2_10_11_1","doi-asserted-by":"crossref","unstructured":"H.Choi \u201cCharge Current Control for LLC Resonant Converter \u201d in (2015):1448\u20131452","DOI":"10.1109\/APEC.2015.7104538"},{"key":"e_1_2_10_12_1","doi-asserted-by":"crossref","unstructured":"Y.Panov \u201cImplementation and Stability of Charge Control for Full\u2010Bridge LLC Converter \u201d in (2021):1859\u20131866","DOI":"10.1109\/APEC42165.2021.9487256"},{"key":"e_1_2_10_13_1","doi-asserted-by":"crossref","unstructured":"M.Farooq S.Poddar T.Merkin andS.Pervaiz \u201cA Feedforward\u2010Enhanced Feedback Hybrid Hysteretic Charge Control for LLC Converters \u201d in (2024):1\u20137.","DOI":"10.1109\/COMPEL57542.2024.10614044"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2014.2313130"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.24295\/CPSSTPEA.2019.00013"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2022.3217596"},{"key":"e_1_2_10_17_1","unstructured":"C.Adragna \u201cTime\u2010Shift Control of LLC Resonant Converters \u201d (2010)."},{"key":"e_1_2_10_18_1","doi-asserted-by":"crossref","unstructured":"C.Adragna D.Ciambellotti M.Dell'Oro andF.Gallenda \u201cDigital Implementation and Performance Evaluation of a Time\u2010Shift\u2010Controlled LLC Resonant Half\u2010Bridge Converter \u201d in (2014):2074\u20132080","DOI":"10.1109\/APEC.2014.6803592"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2024.3463956"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2024.3425377"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2021.3070928"}],"container-title":["International Journal of Circuit Theory and Applications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/cta.70141","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/cta.70141","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/cta.70141","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T10:19:40Z","timestamp":1777371580000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/cta.70141"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,16]]},"references-count":20,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["10.1002\/cta.70141"],"URL":"https:\/\/doi.org\/10.1002\/cta.70141","archive":["Portico"],"relation":{},"ISSN":["0098-9886","1097-007X"],"issn-type":[{"value":"0098-9886","type":"print"},{"value":"1097-007X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,16]]},"assertion":[{"value":"2025-05-08","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-08-28","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-16","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}