{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T13:42:01Z","timestamp":1698068521898},"reference-count":28,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2005,10,20]],"date-time":"2005-10-20T00:00:00Z","timestamp":1129766400000},"content-version":"vor","delay-in-days":5072,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J Imaging Syst Tech"],"published-print":{"date-parts":[[1991,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>We present the recent developments of the Scanning Tomographic Acoustic Microscope (STAM). The STAM was proposed as a method to achieve 3D imaging capability for the Scanning Laser Acoustic Microscope (SLAM). With the addition of a quadrature receiver, the complex scattered wave field can now be detected, and consequently the STAM is capable of subsurface holographic and tomographic imaging. The resolution improvement of the STAM can be attributed directly to the detection of the phase information and the image reconstruction technique. The STAM is sensitive to phase errors in the tomographic projections. In particular, the quadrature phase error and the initial phase error in the complex projections are critical to the tomographic reconstruction process. For multiple\u2010angle tomography, high\u2010precision projection registration and alignment become necessary. By obtaining solutions to these implementation problems, we have succeeded in obtaining images superior to the original SLAM images. In addition, quantitative ultrasonic imaging is possible with the STAM, and a method is presented to image the velocity parameter of simple specimens. With these capabilities, the STAM may become a useful tool for high\u2010resolution subsurface nondestructive evaluation.<\/jats:p>","DOI":"10.1002\/ima.1850030406","type":"journal-article","created":{"date-parts":[[2007,3,5]],"date-time":"2007-03-05T22:49:29Z","timestamp":1173134969000},"page":"334-353","source":"Crossref","is-referenced-by-count":7,"title":["Recent advances in scanning tomographic acoustic microscopy"],"prefix":"10.1002","volume":"3","author":[{"given":"Richard Y.","family":"Chiao","sequence":"first","affiliation":[]},{"given":"Hua","family":"Lee","sequence":"additional","affiliation":[]}],"member":"311","published-online":{"date-parts":[[2005,10,20]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1364\/AO.8.001567"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1109\/PROC.1979.11281"},{"key":"e_1_2_1_4_2","first-page":"15","volume-title":"Acoustical Imaging","author":"Kessler L. W.","year":"1974"},{"issue":"4","key":"e_1_2_1_5_2","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1109\/T-SU.1985.31631","article-title":"Plane\u2010scanning reflection\u2010diffraction tomography","volume":"32","author":"Lan C. Q.","year":"1985","journal-title":"IEEE Trans. Sonics Ultrason."},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1109\/T-SU.1985.31564"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1063\/1.97370"},{"key":"e_1_2_1_8_2","first-page":"627","volume-title":"Proceedings of the 1983 IEEE Ultrasonics Symposium","author":"Lin Z.","year":"1983"},{"key":"e_1_2_1_9_2","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1109\/T-UFFC.1987.26947","article-title":"Holographic image reconstruction in scanning laser acoustic microscopy","volume":"34","author":"Lin Z. C.","year":"1987","journal-title":"IEEE Trans. Ultrason. Ferroelectron. Freq. Control"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4684-1137-9_20"},{"key":"e_1_2_1_11_2","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1109\/T-SU.1984.31547","article-title":"Back\u2010and\u2010forth propagation for diffraction tomography","volume":"31","author":"Lin Z. C.","year":"1984","journal-title":"IEEE Trans. Sonics Ultrason."},{"key":"e_1_2_1_12_2","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1109\/T-SU.1985.31584","article-title":"Scanning tomographic acoustic microscopy: A review","volume":"32","author":"Lin Z. C.","year":"1985","journal-title":"IEEE Trans. Sonics Ultrason."},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1109\/T-SU.1983.31440"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1121\/1.385544"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1109\/T-SU.1985.31601"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1109\/ULTSYM.1988.49474"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1109\/TASSP.1977.1162923"},{"key":"e_1_2_1_18_2","first-page":"54","volume-title":"Introduction to Fourier Optics","author":"Goodman J. W.","year":"1968"},{"key":"e_1_2_1_19_2","unstructured":"R. Y.Chiao \u201cSignal Processing and Image Reconstruction for Scanning Tomographic Acoustic Microscopy \u201d Ph. D. dissertation Department of Electrical and Computer Engineering University of Illinois at Urbana\u2010Champaign 1991."},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1121\/1.392277"},{"key":"e_1_2_1_21_2","first-page":"84","volume-title":"Optimization by Vector Space Methods","author":"Luenberger D. G.","year":"1969"},{"key":"e_1_2_1_22_2","first-page":"1508","volume-title":"Proceedings of 1989 IEEE International Conference on Acoustics, Speech and Signal Processing","author":"Chiao R. Y.","year":"1989"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-12-266719-0.50006-3"},{"key":"e_1_2_1_24_2","doi-asserted-by":"crossref","unstructured":"M.\u2010K.Hu \u201cVisual pattern recognition by moment invariants \u201dIRE Trans. Inf. Theory 179\u2013187(1962).","DOI":"10.1109\/TIT.1962.1057692"},{"key":"e_1_2_1_25_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPAMI.1987.4767965"},{"key":"e_1_2_1_26_2","volume-title":"Applied Linear Algebra","author":"Noble B.","year":"1979"},{"key":"e_1_2_1_27_2","doi-asserted-by":"publisher","DOI":"10.1109\/TASSP.1982.1163965"},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.1109\/29.46552"},{"key":"e_1_2_1_29_2","doi-asserted-by":"publisher","DOI":"10.1109\/29.1630"}],"container-title":["International Journal of Imaging Systems and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fima.1850030406","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ima.1850030406","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T00:41:24Z","timestamp":1698021684000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ima.1850030406"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1991,12]]},"references-count":28,"journal-issue":{"issue":"4","published-print":{"date-parts":[[1991,12]]}},"alternative-id":["10.1002\/ima.1850030406"],"URL":"https:\/\/doi.org\/10.1002\/ima.1850030406","archive":["Portico"],"relation":{},"ISSN":["0899-9457","1098-1098"],"issn-type":[{"value":"0899-9457","type":"print"},{"value":"1098-1098","type":"electronic"}],"subject":[],"published":{"date-parts":[[1991,12]]}}}