{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T06:40:59Z","timestamp":1693550459608},"reference-count":17,"publisher":"Wiley","issue":"2-3","license":[{"start":{"date-parts":[[2005,10,20]],"date-time":"2005-10-20T00:00:00Z","timestamp":1129766400000},"content-version":"vor","delay-in-days":3794,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J Imaging Syst Tech"],"published-print":{"date-parts":[[1995,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>In this article, we have described a tailored radio frequency gradient echo (TRFGE) technique which is applied to functional imaging. The TRFGE technique is insensitive to the inflow effect, which often complicates the analysis of functional magnetic resonance imaging (FMRI) data, and is also insensitive to nonfunctional backgrounds such as static tissues. The susceptibility effect measurement obtained from the TRFGE technique therefore provides a unique form of functional imaging, namely, susceptibility\u2010only functional imaging. To examine TRFGE functional imaging systematically, we designed an experiment to determine the flow effect and susceptibility\u2010dependent signal change by varying the imaging parameters including flip angle \u03b1, repetition time TR, and echo time TE. The results obtained were then compared with the data obtained with conventional gradient\u2010echo (CGE) functional MR imaging. The experimental results shown were all obtained using human volunteers with a 2.0\u2010T whole\u2010body MRI system.<\/jats:p>","DOI":"10.1002\/ima.1850060205","type":"journal-article","created":{"date-parts":[[2007,3,5]],"date-time":"2007-03-05T23:32:18Z","timestamp":1173137538000},"page":"164-170","source":"Crossref","is-referenced-by-count":2,"title":["Susceptibility effect\u2010enhanced functional MR imaging using tailored RF gradient echo (TRFGE) sequence"],"prefix":"10.1002","volume":"6","author":[{"given":"Z. H.","family":"Cho","sequence":"first","affiliation":[]},{"given":"Y. M.","family":"Ro","sequence":"additional","affiliation":[]},{"given":"S. C.","family":"Chung","sequence":"additional","affiliation":[]}],"member":"311","published-online":{"date-parts":[[2005,10,20]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.87.24.9868"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.89.12.5675"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910250220"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1152\/jn.1993.69.1.297"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910290221"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910290126"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.83.4.1140"},{"key":"e_1_2_1_9_2","unstructured":"C. E.Stern K. K.Kwong J. W.Belliveau J. R.Baker andB. R.Rosen. \u201cMR tracking of physiological mechanisms underlying brain activity \u201d in Book of Abstracts 11th Annual Meeting SMRM 1992 p.1821."},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910280104"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910230120"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910280206"},{"key":"e_1_2_1_13_2","unstructured":"Z. H.Cho Y. M.Ro J. B.Park S. C.Chung andS. H.Park. \u201cFunctional brain imaging using blood flow changes \u201d in Proc. SMRM 12th Annual Meeting 1993 p.170."},{"key":"e_1_2_1_14_2","unstructured":"Z. H.Cho Y. M.Ro Sh. H.Park S. C.Chung andR.Ong.\u201cNMR functional imaging using tailored RF gradient echo sequence\u2014a true susceptibility measurement technique \u201d Proc. SMR Second Meeting 1994 p.659."},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-2364(90)90303-Q"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1088\/0022-3719\/10\/3\/004"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.1986.4307732"},{"key":"e_1_2_1_18_2","unstructured":"Z. H.Cho C. B.Ahn J. H.Kim Y. E.Lee andC. W.Mun. Book of Abstracts 6th SMRM vol. 2 p.912(1987)."}],"container-title":["International Journal of Imaging Systems and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fima.1850060205","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ima.1850060205","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T07:28:29Z","timestamp":1693466909000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ima.1850060205"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1995,6]]},"references-count":17,"journal-issue":{"issue":"2-3","published-print":{"date-parts":[[1995,6]]}},"alternative-id":["10.1002\/ima.1850060205"],"URL":"https:\/\/doi.org\/10.1002\/ima.1850060205","archive":["Portico"],"relation":{},"ISSN":["0899-9457","1098-1098"],"issn-type":[{"value":"0899-9457","type":"print"},{"value":"1098-1098","type":"electronic"}],"subject":[],"published":{"date-parts":[[1995,6]]}}}