{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,17]],"date-time":"2023-10-17T00:25:30Z","timestamp":1697502330068},"reference-count":46,"publisher":"Wiley","issue":"2-3","license":[{"start":{"date-parts":[[2005,10,20]],"date-time":"2005-10-20T00:00:00Z","timestamp":1129766400000},"content-version":"vor","delay-in-days":3794,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J Imaging Syst Tech"],"published-print":{"date-parts":[[1995,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>This article describes a novel MRI technique as well as its variant, which use prior knowledge to acquire and reconstruct the principal components of an image to reduce scanning time. Examples in the application of this technique are given. The implications of these results and the potential in the application of the functional imaging are discussed.<\/jats:p>","DOI":"10.1002\/ima.1850060209","type":"journal-article","created":{"date-parts":[[2007,3,5]],"date-time":"2007-03-05T23:32:18Z","timestamp":1173137538000},"page":"191-202","source":"Crossref","is-referenced-by-count":2,"title":["Acquisition and reconstruction of the principal components of an image: A novel MRI technique for reducing scanning time"],"prefix":"10.1002","volume":"6","author":[{"given":"Yue","family":"Cao","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David N.","family":"Levin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,10,20]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-2364(86)90433-6"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910130109"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910030602"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-2364(78)90159-2"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910290222"},{"key":"e_1_2_1_7_2","first-page":"67","article-title":"Constrained reconstruction methods in MR imaging","volume":"4","author":"Liang Z. P.","year":"1992","journal-title":"Rev. Mag. Res. Med."},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1118\/1.596427"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910170115"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910080308"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1109\/ICIP.1994.413899"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1109\/42.97578"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1109\/42.79470"},{"key":"e_1_2_1_14_2","unstructured":"Z. P.LiangandP. C.Lauterbur \u201cAn efficient method for dynamic magnetic resonance imaging \u201dIEEE Trans. Med. Imag.in press."},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910290618"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880030419"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910310618"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910300306"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1117\/12.175060"},{"key":"e_1_2_1_20_2","doi-asserted-by":"crossref","unstructured":"Y.CaoandD. N.Levin \u201cUsing an image database constrain the acquisition and reconstruction of MR images of the human head \u201dIEEE Trans. Med. Imag.submitted1994.","DOI":"10.1117\/12.175060"},{"key":"e_1_2_1_21_2","doi-asserted-by":"crossref","unstructured":"Y.Cao D. N.Levin andL.Yao \u201cLocally focused MRI \u201dMagn. Reson. Med. submitted1994.","DOI":"10.1002\/mrm.1910340611"},{"key":"e_1_2_1_22_2","doi-asserted-by":"crossref","unstructured":"Y.CaoandD. N.Levin Locally focused MRI Proc. IEEE Internat. Conf. on Image Proc. Austin TX 1994 pp.30\u201334.","DOI":"10.1002\/mrm.1910340611"},{"key":"e_1_2_1_23_2","first-page":"60","article-title":"Using prior knowledge of human anatomy to constrain half k\u2010space MR image acquisition and reconstruction","volume":"1","author":"Cao Y.","year":"1994","journal-title":"Proc. Soc. Magn. Reson."},{"key":"e_1_2_1_24_2","unstructured":"Y.CaoandD. N.Levin \u201cUsing prior knowledge of human anatomy to constrain MR image acquisition and reconstruction: Half k\u2010space and full k\u2010space techniques \u201d submitted for publication."},{"key":"e_1_2_1_25_2","first-page":"159","volume-title":"Pattern Recognition","author":"Watanabe S.","year":"1985"},{"key":"e_1_2_1_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/0031-3203(81)90082-0"},{"key":"e_1_2_1_27_2","first-page":"230","volume-title":"Classification, Estimation, and Pattern Recognition","author":"Young T. Y.","year":"1974"},{"key":"e_1_2_1_28_2","volume-title":"SVD and Signal Processing","author":"Dewilde P.","year":"1988"},{"key":"e_1_2_1_29_2","doi-asserted-by":"publisher","DOI":"10.1126\/science.220.4598.671"},{"key":"e_1_2_1_30_2","unstructured":"S. J.ReevesandL. P.Heck \u201cSelection of observations in signal reconstruction \u201d IEEE Trans. Signal Processing in press."},{"key":"e_1_2_1_31_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.161.2.3763926"},{"key":"e_1_2_1_32_2","first-page":"195","article-title":"Faster MR imaging: Imaging with half the data","volume":"1","author":"Margosian P.","year":"1986","journal-title":"Healthcare Instr."},{"key":"e_1_2_1_33_2","doi-asserted-by":"publisher","DOI":"10.1109\/42.79473"},{"key":"e_1_2_1_34_2","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.1982.4307556"},{"key":"e_1_2_1_35_2","doi-asserted-by":"crossref","unstructured":"J. J.CuppenandA.Van Est Reducting MR imaging time by one\u2010sided reconstruction Topical Conf. Fast MRI Techniques Cleveland Ohio 1987.","DOI":"10.1016\/0730-725X(87)90402-4"},{"key":"e_1_2_1_36_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910300109"},{"key":"e_1_2_1_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/0730-725X(90)90216-O"},{"key":"e_1_2_1_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-2364(91)90253-P"},{"key":"e_1_2_1_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/0730-725X(88)90444-4"},{"key":"e_1_2_1_40_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880010416"},{"key":"e_1_2_1_41_2","doi-asserted-by":"publisher","DOI":"10.1109\/18.119740"},{"key":"e_1_2_1_42_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880030415"},{"key":"e_1_2_1_43_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910240209"},{"key":"e_1_2_1_44_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910320219"},{"key":"e_1_2_1_45_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910330122"},{"key":"e_1_2_1_46_2","doi-asserted-by":"publisher","DOI":"10.1109\/ICIP.1994.413893"},{"key":"e_1_2_1_47_2","unstructured":"L.Yao Y.Cao andD. N.Levin \u201cTwo dimensional locally focused MRI \u201d submitted for publication."}],"container-title":["International Journal of Imaging Systems and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fima.1850060209","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ima.1850060209","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T07:30:13Z","timestamp":1693467013000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ima.1850060209"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1995,6]]},"references-count":46,"journal-issue":{"issue":"2-3","published-print":{"date-parts":[[1995,6]]}},"alternative-id":["10.1002\/ima.1850060209"],"URL":"https:\/\/doi.org\/10.1002\/ima.1850060209","archive":["Portico"],"relation":{},"ISSN":["0899-9457","1098-1098"],"issn-type":[{"value":"0899-9457","type":"print"},{"value":"1098-1098","type":"electronic"}],"subject":[],"published":{"date-parts":[[1995,6]]}}}