{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T17:00:10Z","timestamp":1761843610165},"reference-count":22,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2005,11,22]],"date-time":"2005-11-22T00:00:00Z","timestamp":1132617600000},"content-version":"vor","delay-in-days":4039,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[1994,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>For sequential studies of patients with brain tumors, the authors have designed an automated registration procedure for intra\u2010 and interexamination alignment of magnetic resonance images. This was evaluated with artificially misregistered data and data from repeat studies of six healthy volunteers and six brain tumor patients. In a subset of cases, a manual procedure based on matching of neuroanatomic landmarks was also applied for comparison. The results showed that the technique is robust and reproducible, giving an accuracy in the range of 1\u20132 mm, which corresponded to the spatial resolution of the images. Subject motion between imaging sequences within the same study was negligible, although adjustments (one to two section thicknesses) were required in the z direction to correlate multisection and volume images and to allow accurate image segmentation. For alignment between sequential volunteer and patient examinations, translations of up to 22 mm and rotations in the x, y, and z axes of up to 9\u00b0 were required. This alignment procedure may be valuable in numerous aspects of treatment planning and patient follow\u2010up.<\/jats:p>","DOI":"10.1002\/jmri.1880040621","type":"journal-article","created":{"date-parts":[[2007,3,6]],"date-time":"2007-03-06T03:14:17Z","timestamp":1173150857000},"page":"877-883","source":"Crossref","is-referenced-by-count":53,"title":["Registration of images from sequential MR studies of the brain"],"prefix":"10.1002","volume":"4","author":[{"given":"Sarah J.","family":"Nelson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Allen B.","family":"Nalbandian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Evelyn","family":"Proctor","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel B.","family":"Vigneron","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,11,22]]},"reference":[{"key":"e_1_2_1_2_2","first-page":"3802","volume-title":"Book of abstracts: Society of Magnetic Resonance in Medicine 1992","author":"Nelson SJ","year":"1992"},{"key":"e_1_2_1_3_2","first-page":"52","volume-title":"Book of abstracts: Society of Magnetic Resonance in Medicine 1992","author":"Vigneron DB","year":"1992"},{"key":"e_1_2_1_4_2","first-page":"4207","volume-title":"Book of abstracts: Society of Magnetic Resonance in Medicine 1992","author":"Nelson SJ","year":"1992"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-198901000-00004"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.169.3.3263666"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-198102000-00027"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-198208000-00043"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-198412000-00042"},{"key":"e_1_2_1_10_2","first-page":"634","article-title":"Correlation of structural and functional images in the same patient (abstr)","volume":"28","author":"Martin WRW","year":"1987","journal-title":"J Nucl Med"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1038\/jcbfm.1988.92"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-198803000-00038"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-198901000-00045"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-199005000-00019"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-198711000-00005"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1992.76.3.0444"},{"key":"e_1_2_1_17_2","first-page":"266","volume-title":"Information processing in medical imaging","author":"Maguire GQ","year":"1985"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/37\/1\/019"},{"key":"e_1_2_1_19_2","first-page":"51","article-title":"Three\u2010dimensional alignment of functional and morphological tomograms","volume":"14","author":"Pietrzyk U","year":"1990","journal-title":"J Comput Assist Tomogr"},{"key":"e_1_2_1_20_2","first-page":"682","article-title":"Three dimensional correlation of PET, CT and MRI images (abstr)","volume":"28","author":"Pelizzari CA","year":"1987","journal-title":"J Nucl Med"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.172.3.2788893"},{"key":"e_1_2_1_22_2","first-page":"36","article-title":"Peak detection and quantification in NMR spectra using the PIQABLE algorithm","volume":"11","author":"Nelson SJ","year":"1990","journal-title":"Bull Magn Reson"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1991.74.5.0845"}],"container-title":["Journal of Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjmri.1880040621","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.1880040621","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,24]],"date-time":"2023-10-24T05:44:15Z","timestamp":1698126255000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.1880040621"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1994,11]]},"references-count":22,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1994,11]]}},"alternative-id":["10.1002\/jmri.1880040621"],"URL":"https:\/\/doi.org\/10.1002\/jmri.1880040621","archive":["Portico"],"relation":{},"ISSN":["1053-1807","1522-2586"],"issn-type":[{"value":"1053-1807","type":"print"},{"value":"1522-2586","type":"electronic"}],"subject":[],"published":{"date-parts":[[1994,11]]}}}