{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T01:57:47Z","timestamp":1777427867573,"version":"3.51.4"},"reference-count":21,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2006,1,12]],"date-time":"2006-01-12T00:00:00Z","timestamp":1137024000000},"content-version":"vor","delay-in-days":2964,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[1997,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Signal phase variations caused by physiology are a major source of instability in fMRI images produced by multiple RF pulses. <jats:italic>k<\/jats:italic>\u2010Space phase variation maps show cyclic phase variations at the frequency of respiration combined with a cardiac variation of lower amplitude. The amplitude of the variation increases with gradient echo time and proximity to the chest, suggesting that the dominant cause of the phase variation is a <jats:italic>B<\/jats:italic><jats:sub>0<\/jats:sub> shift (\u223c0.01 ppm) produced by movement of organs in the chest. A simple <jats:italic>k<\/jats:italic>\u2010space phase correction method is proposed and demonstrated for FLASH fMRI. The retrospective method requires no pulse sequence modification, and is more effective than navigator echo correction. Physiological noise is dramatically reduced, especially at inferior slice locations.<\/jats:p>","DOI":"10.1002\/mrm.1910380625","type":"journal-article","created":{"date-parts":[[2007,3,13]],"date-time":"2007-03-13T12:17:19Z","timestamp":1173788239000},"page":"1029-1034","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":70,"title":["<i>k<\/i>\u2010space detection and correction of physiological artifacts in fMRI"],"prefix":"10.1002","volume":"38","author":[{"given":"Brian","family":"Wowk","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael C.","family":"McIntyre","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John K.","family":"Saunders","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,1,12]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.89.12.5675"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880020505"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910310307"},{"key":"e_1_2_1_5_2","unstructured":"R. M.Weisskoff J.Baker J.Belliveau T. L.Davis K. K.Kwong M. S.Cohen B. R.Rosen Power spectrum analysis of functionally weighted MR data: what's in the noise? in\u201cProc. SMRM 12th Annual Meeting New York 1993 \u201d p.7."},{"key":"e_1_2_1_6_2","unstructured":"P.Jezzard D.LeBihan C.Cuenod L.Pannier A.Prinster R.Turner An investigation of the contribution of physiological noise in human functional MRI studies at 1.5 Tesla and 4 Tesla in\u201cProc. SMRM 12th Annual Meeting New York 1993 \u201d p.1392."},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910350312"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910300204"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910350114"},{"key":"e_1_2_1_10_2","unstructured":"D. C.Noll W.Schneider J. D.Cohen Artifacts in functional MRI using conventional scanning in\u201cProc. SMRM 12th Annual Meeting New York 1993 \u201d p.1407."},{"key":"e_1_2_1_11_2","unstructured":"D. C.Noll W.Schneider Respiration artifacts in functional brain imaging: sources of signal variation and compensation strategies in\u201cProc. SMR 2nd Annual Meeting San Francisco 1994 \u201d p.647."},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910310505"},{"key":"e_1_2_1_13_2","unstructured":"B.Wowk M. C.McIntyre J. K.Suanders Physiologic artifact correction in fMRI without navigator echoes.in\u201cProc. ISMRM 4th Annual Meeting New York 1996 \u201d p.1822."},{"key":"e_1_2_1_14_2","unstructured":"D. C.Noll J.O'Brien Simulation of physiological effects in functional MRI in\u201cProc. SMR\/ESMRMB Annual Meeting Nice 1995 \u201d p.794."},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910330507"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910340211"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910350305"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910340423"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910340327"},{"key":"e_1_2_1_20_2","unstructured":"R. S.Menon H.Merkle K. U 151 urbil A novel multislice FLASH sequence for functional magnetic resonance imaging in\u201cProc. SMRM 12th Annual Meeting New York 1993 \u201d p.1203."},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910300617"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910350613"}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmrm.1910380625","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.1910380625","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,28]],"date-time":"2023-10-28T05:45:16Z","timestamp":1698471916000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.1910380625"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1997,12]]},"references-count":21,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1997,12]]}},"alternative-id":["10.1002\/mrm.1910380625"],"URL":"https:\/\/doi.org\/10.1002\/mrm.1910380625","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[1997,12]]},"assertion":[{"value":"1996-09-09","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"1997-06-11","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2006-01-12","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}