{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T15:42:12Z","timestamp":1792165332059,"version":"4.4.0"},"reference-count":11,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2017,8,30]],"date-time":"2017-08-30T00:00:00Z","timestamp":1504051200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2017,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Introduction<\/jats:title><jats:p>Designing a radiation plan that optimally delivers both target coverage and normal tissue sparing is challenging. There are limited tools to determine what is dosimetrically achievable and frequently the experience of the planner\/physician is relied upon to make these determinations. Plan<jats:styled-content style=\"fixed-case\">IQ<\/jats:styled-content> software provides a tool that uses target and organ at risk (<jats:styled-content style=\"fixed-case\">OAR<\/jats:styled-content>) geometry to indicate the difficulty of achieving different points for organ dose\u2013volume histograms (<jats:styled-content style=\"fixed-case\">DVH<\/jats:styled-content>). We hypothesized that Plan<jats:styled-content style=\"fixed-case\">IQ<\/jats:styled-content> Feasibility <jats:styled-content style=\"fixed-case\">DVH<\/jats:styled-content> may aid planners in reducing dose to <jats:styled-content style=\"fixed-case\">OAR<\/jats:styled-content>s.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods and materials<\/jats:title><jats:p>Clinically delivered head and neck treatments (clinical plan) were re\u2010planned (re\u2010plan) putting high emphasis on maximally sparing the contralateral parotid gland, contralateral submandibular gland, and larynx while maintaining routine clinical dosimetric objectives. The planner was blinded to the results of the clinically delivered plan as well as the Feasibility <jats:styled-content style=\"fixed-case\">DVH<\/jats:styled-content>s from Plan<jats:styled-content style=\"fixed-case\">IQ<\/jats:styled-content>. The re\u2010plan treatments were designed using 3\u2010arc <jats:styled-content style=\"fixed-case\">VMAT<\/jats:styled-content> in Raystation (RaySearch Laboratories, Sweden). The planner was then given the results from the Plan<jats:styled-content style=\"fixed-case\">IQ<\/jats:styled-content> Feasibility <jats:styled-content style=\"fixed-case\">DVH<\/jats:styled-content> analysis and developed an additional plan incorporating this information using 4\u2010arc <jats:styled-content style=\"fixed-case\">VMAT<\/jats:styled-content> (<jats:styled-content style=\"fixed-case\">IQ<\/jats:styled-content> plan). The <jats:styled-content style=\"fixed-case\">DVH<\/jats:styled-content>s across the three treatment plans were compared with what was deemed \u201cimpossible\u201d by Plan<jats:styled-content style=\"fixed-case\">IQ<\/jats:styled-content>'s Feasibility <jats:styled-content style=\"fixed-case\">DVH<\/jats:styled-content> (Impossible <jats:styled-content style=\"fixed-case\">DVH<\/jats:styled-content>). The impossible <jats:styled-content style=\"fixed-case\">DVH<\/jats:styled-content> (red) is defined as the <jats:styled-content style=\"fixed-case\">DVH<\/jats:styled-content> generated using the minimal dose that any voxel outside the targets must receive given 100% target coverage.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The re\u2010plans performed blinded to Plan<jats:styled-content style=\"fixed-case\">IQ<\/jats:styled-content> Feasibilty <jats:styled-content style=\"fixed-case\">DVH<\/jats:styled-content> achieved superior sparing of aforementioned <jats:styled-content style=\"fixed-case\">OAR<\/jats:styled-content>s compared to the clinically delivered plans and resulted in discrepancies from the impossible <jats:styled-content style=\"fixed-case\">DVH<\/jats:styled-content>s by an average of 200\u2013700 <jats:styled-content style=\"fixed-case\">cG<\/jats:styled-content>y. Using the Plan<jats:styled-content style=\"fixed-case\">IQ<\/jats:styled-content> Feasibility <jats:styled-content style=\"fixed-case\">DVH<\/jats:styled-content> led to <jats:italic>additional<\/jats:italic><jats:styled-content style=\"fixed-case\">OAR<\/jats:styled-content> sparing compared to both the re\u2010plans and clinical plans and reduced the discrepancies from the impossible <jats:styled-content style=\"fixed-case\">DVH<\/jats:styled-content>s to an average of approximately 100 <jats:styled-content style=\"fixed-case\">cG<\/jats:styled-content>y. The dose reduction from clinical to re\u2010plan and re\u2010plan to <jats:styled-content style=\"fixed-case\">IQ<\/jats:styled-content> plan were significantly different even when taking into account multiple hypothesis testing for both the contralateral parotid and the larynx (<jats:italic>P<\/jats:italic> &lt; 0.004 for all comparisons). No significant differences were observed between the three plans for the contralateral parotid when considering multiple hypothesis testing.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Clinical treatment plans and blinded re\u2010plans were found to suboptimally spare <jats:styled-content style=\"fixed-case\">OAR<\/jats:styled-content>s. Plan<jats:styled-content style=\"fixed-case\">IQ<\/jats:styled-content> could aid planners in generating treatment plans that push the limits of <jats:styled-content style=\"fixed-case\">OAR<\/jats:styled-content> sparing while maintaining routine clinical target coverage goals.<\/jats:p><\/jats:sec>","DOI":"10.1002\/acm2.12165","type":"journal-article","created":{"date-parts":[[2017,8,31]],"date-time":"2017-08-31T11:38:34Z","timestamp":1504179514000},"page":"245-250","source":"Crossref","is-referenced-by-count":35,"title":["Assessment of Plan<scp>IQ<\/scp> Feasibility <scp>DVH<\/scp> for head and neck treatment planning"],"prefix":"10.1002","volume":"18","author":[{"given":"David V.","family":"Fried","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology University of North Carolina at Chapel Hill Chapel Hill NC USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bhishamjit S.","family":"Chera","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology University of North Carolina at Chapel Hill Chapel Hill NC USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shiva K.","family":"Das","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology University of North Carolina at Chapel Hill Chapel Hill NC USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,8,30]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prro.2011.11.012"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1470-2045(10)70290-4"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2009.06.090"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-014-0255-x"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2011.09.004"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2009.03.079"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2007.01.047"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2014.12.045"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2009.24.6199"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2014.11.014"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.12500"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Facm2.12165","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.12165","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/acm2.12165","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.12165","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,10]],"date-time":"2023-09-10T16:16:49Z","timestamp":1694362609000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.12165"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8,30]]},"references-count":11,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2017,9]]}},"alternative-id":["10.1002\/acm2.12165"],"URL":"https:\/\/doi.org\/10.1002\/acm2.12165","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,8,30]]}}}