{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T00:08:27Z","timestamp":1790208507572,"version":"4.1.0"},"reference-count":28,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2018,6,14]],"date-time":"2018-06-14T00:00:00Z","timestamp":1528934400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2018,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    This study details a validation process for linear accelerator\u2010based treatment of trigeminal neuralgia using\n                    <jats:styled-content style=\"fixed-case\">HD<\/jats:styled-content>\n                    \u2010\n                    <jats:styled-content style=\"fixed-case\">MLC<\/jats:styled-content>\n                    field collimation. Nine trigeminal neuralgia treatment plans utilizing\n                    <jats:styled-content style=\"fixed-case\">HD<\/jats:styled-content>\n                    \u2010\n                    <jats:styled-content style=\"fixed-case\">MLC<\/jats:styled-content>\n                    were selected for absolute dose measurement at isocenter using a commercial scintillating detector in an anthropomorphic phantom. Four plans were chosen for film dosimetry measurements in each of the three principal planes to assess spatial dose distribution agreement with the treatment planning system. Additionally, trajectory log analysis for each treatment field in the nine cases was performed to assess mechanical positioning accuracy of the\n                    <jats:styled-content style=\"fixed-case\">MLC<\/jats:styled-content>\n                    system during delivery. Scintillator and film measurements both revealed mean dose agreement at isocenter of better than 3% while\n                    <jats:styled-content style=\"fixed-case\">FWHM<\/jats:styled-content>\n                    of the 2D dose distribution in each plane showed agreement between plan and measurement within 0.2\u00a0mm. Analysis of log files revealed a maximum\n                    <jats:styled-content style=\"fixed-case\">MLC<\/jats:styled-content>\n                    leaf positioning error of 0.04\u00a0mm across 178 treatment fields. In conjunction with a quality\u2010controlled treatment delivery methodology, an appropriately commissioned treatment planning system can be used for accurate and clinically appropriate design of trigeminal neuralgia treatment plans utilizing\n                    <jats:styled-content style=\"fixed-case\">HD<\/jats:styled-content>\n                    \u2010\n                    <jats:styled-content style=\"fixed-case\">MLC<\/jats:styled-content>\n                    .\n                  <\/jats:p>","DOI":"10.1002\/acm2.12381","type":"journal-article","created":{"date-parts":[[2018,6,14]],"date-time":"2018-06-14T07:16:39Z","timestamp":1528960599000},"page":"214-221","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Validation of\n                    <scp>MLC<\/scp>\n                    \u2010based linac radiosurgery for trigeminal neuralgia"],"prefix":"10.1002","volume":"19","author":[{"given":"M. Tynan R.","family":"Stevens","sequence":"first","affiliation":[{"name":"Department of Radiation and Cellular Oncology University of Chicago Medicine Chicago IL USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric C.","family":"Lobb","sequence":"additional","affiliation":[{"name":"Department of Radiation and Cellular Oncology University of Chicago Medicine Chicago IL USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kamil M.","family":"Yenice","sequence":"additional","affiliation":[{"name":"Department of Radiation and Cellular Oncology University of Chicago Medicine Chicago IL USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2018,6,14]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2969268"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/0360-3016(88)90446-4"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/roi.2970010111"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-8140(99)00020-1"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v12i3.3475"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4790563"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/1533034615574385"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(00)01537-6"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacr.2008.11.016"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.62.4.660"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4903757"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/38\/7\/005"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3562896"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1109\/TNS.2002.803680"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2008487"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.598407"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF03178579"},{"key":"e_1_2_6_19_1","first-page":"194","article-title":"Radiochromic EBT film dosimetry: effect of film orientation and batch on the lateral correction of the scanner","volume":"84","author":"Paelinck L","year":"2007","journal-title":"Radiother Oncol"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3223621"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4947295"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-016-0709-4"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v14i6.4493"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/44\/4\/006"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.1567736"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3641644"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2731031"},{"key":"e_1_2_6_28_1","first-page":"140","article-title":"An analysis of the accuracy of the CyberKnifeL A robotic frameless stereotactic radiosurgical system","volume":"52","author":"Chang S","year":"2003","journal-title":"Neurosurgery"},{"key":"e_1_2_6_29_1","unstructured":"AspradakisMM ByrneJP PalmansH et\u00a0al.IPEM report 103: Small field MV photon dosimetry.Inst Phys Eng Med;2010:1\u2013186."}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Facm2.12381","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.12381","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,18]],"date-time":"2023-09-18T05:17:49Z","timestamp":1695014269000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.12381"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,14]]},"references-count":28,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018,7]]}},"alternative-id":["10.1002\/acm2.12381"],"URL":"https:\/\/doi.org\/10.1002\/acm2.12381","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,14]]},"assertion":[{"value":"2017-12-26","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-05-16","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-06-14","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}