{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T18:56:51Z","timestamp":1790621811870,"version":"4.1.0"},"reference-count":40,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2018,10,27]],"date-time":"2018-10-27T00:00:00Z","timestamp":1540598400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2018,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objectives<\/jats:title><jats:p>To evaluate the influence of <jats:styled-content style=\"fixed-case\">MRI<\/jats:styled-content> scanning parameters on texture analysis features.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Publicly available data from the Reference Image Database to Evaluate Therapy Response (<jats:styled-content style=\"fixed-case\">RIDER<\/jats:styled-content>) project sponsored by The Cancer Imaging Archive included <jats:styled-content style=\"fixed-case\">MRI<\/jats:styled-content>s on a phantom comprised of 18 25\u2010mm doped, gel\u2010filled tubes, and 1 20\u2010mm tube containing 0.25\u00a0mM Gd\u2010<jats:styled-content style=\"fixed-case\">DTPA<\/jats:styled-content> (EuroSpin<jats:styled-content style=\"fixed-case\">II<\/jats:styled-content> Test Object5, Diagnostic Sonar, Ltd, West Lothian, Scotland). <jats:styled-content style=\"fixed-case\">MRI<\/jats:styled-content>s performed on a 1.5\u00a0T <jats:styled-content style=\"fixed-case\">GE HD<\/jats:styled-content>, 1.5\u00a0T Siemens Espree (<jats:styled-content style=\"fixed-case\">VB<\/jats:styled-content>13), or 3.0\u00a0T <jats:styled-content style=\"fixed-case\">GE HD<\/jats:styled-content> with TwinSpeed gradients with an eight\u2010channel head coil included T1<jats:styled-content style=\"fixed-case\">WI<\/jats:styled-content>s with multiple flip angles (flip\u2010angle\u00a0=\u00a02,5,10,15,20,25,30), <jats:styled-content style=\"fixed-case\">TR<\/jats:styled-content>\/<jats:styled-content style=\"fixed-case\">TE<\/jats:styled-content>\u00a0=\u00a04.09\u20135.47\/0.90\u20131.35\u00a0ms, <jats:styled-content style=\"fixed-case\">NEX<\/jats:styled-content>\u00a0=\u00a01 and <jats:styled-content style=\"fixed-case\">DCE<\/jats:styled-content> with 30\u00b0 flip\u2010angle, <jats:styled-content style=\"fixed-case\">TR<\/jats:styled-content>\/<jats:styled-content style=\"fixed-case\">TE<\/jats:styled-content>=4.09\u20135.47\/0.90\u20131.35, and <jats:styled-content style=\"fixed-case\">NEX<\/jats:styled-content>\u00a0=\u00a01,4. <jats:styled-content style=\"fixed-case\">DICOM<\/jats:styled-content> data were imported into an in\u2010house developed texture analysis program which extracted 41\u2010texture features including histogram, gray\u2010level co\u2010occurrence matrix (<jats:styled-content style=\"fixed-case\">GLCM<\/jats:styled-content>), and gray\u2010level run\u2010length (<jats:styled-content style=\"fixed-case\">GLRL<\/jats:styled-content>). Two\u2010tailed <jats:italic>t<\/jats:italic> tests, corrected for multiple comparisons (<jats:italic>Q<\/jats:italic> values) were calculated to compare changes in texture features with variations in <jats:styled-content style=\"fixed-case\">MRI<\/jats:styled-content> scanning parameters (magnet strength, flip\u2010angle, number of excitations (<jats:styled-content style=\"fixed-case\">NEX<\/jats:styled-content>), scanner platform).<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Significant differences were seen in histogram features (mean, median, standard deviation, range) with variations in <jats:styled-content style=\"fixed-case\">NEX<\/jats:styled-content> (<jats:italic>Q\u00a0<\/jats:italic>=\u00a00.003\u20130.045) and scanner platform (<jats:italic>Q\u00a0<\/jats:italic>&lt;\u00a00.0001), <jats:styled-content style=\"fixed-case\">GLCM<\/jats:styled-content> features (entropy, contrast, energy, and homogeneity) with <jats:styled-content style=\"fixed-case\">NEX<\/jats:styled-content> (<jats:italic>Q\u00a0<\/jats:italic>=\u00a00.001\u20130.018) and scanner platform (<jats:italic>Q\u00a0<\/jats:italic>&lt;\u00a00.0001), <jats:styled-content style=\"fixed-case\">GLRL<\/jats:styled-content> features (long\u2010run emphasis, high gray\u2010level run emphasis, high gray\u2010level emphasis) with magnet strength (<jats:italic>Q\u00a0<\/jats:italic>=\u00a00.0003), <jats:styled-content style=\"fixed-case\">NEX<\/jats:styled-content> (<jats:italic>Q\u00a0<\/jats:italic>=\u00a00.003\u20130.022) and scanner platform (<jats:italic>Q\u00a0<\/jats:italic>&lt;\u00a00.0001).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Significant differences were seen in many texture features with variations in <jats:styled-content style=\"fixed-case\">MRI<\/jats:styled-content> acquisition emphasizing the need for standardized <jats:styled-content style=\"fixed-case\">MRI<\/jats:styled-content> technique.<\/jats:p><\/jats:sec>","DOI":"10.1002\/acm2.12482","type":"journal-article","created":{"date-parts":[[2018,10,28]],"date-time":"2018-10-28T04:58:43Z","timestamp":1540702723000},"page":"253-264","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":78,"title":["Quantitative variations in texture analysis features dependent on <scp>MRI<\/scp> scanning parameters: A phantom model"],"prefix":"10.1002","volume":"19","author":[{"given":"Karen","family":"Buch","sequence":"first","affiliation":[{"name":"Department of Radiology Boston Medical Center Boston University School of Medicine Boston MA USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hirofumi","family":"Kuno","sequence":"additional","affiliation":[{"name":"Department of Radiology Boston Medical Center Boston University School of Medicine Boston MA USA"},{"name":"Department of Diagnostic Radiology National Cancer Center Hospital East Kashiwa Chiba Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad M.","family":"Qureshi","sequence":"additional","affiliation":[{"name":"Departments of Radiology and Radiation Oncology Boston Medical Center Boston University School of Medicine Boston MA USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Baojun","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Radiology Boston Medical Center Boston University School of Medicine Boston MA USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Osamu","family":"Sakai","sequence":"additional","affiliation":[{"name":"Departments of Radiology, Otolaryngology \u2013 Head and Neck Surgery, and Radiation Oncology Boston Medical Center Boston University School of Medicine Boston MA USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2018,10,27]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.1973.4309314"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24174"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.1803"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.1725"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.10100853"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.10042"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2016.11.008"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4285"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2015.12.009"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5106"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2018.00131"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2017.11.007"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2013.06.024"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2502071879"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00261-015-0438-4"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1186\/1755-8794-7-30"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1158\/1078-0432.CCR-16-0702"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000349"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clineuro.2017.12.007"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/59\/18\/5387"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000174"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.14.13279"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25669"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.12898"},{"key":"e_1_2_9_26_1","article-title":"Radiomic features from pretreatment biparametric MRI predict prostate cancer biochemical recurrence: preliminary findings","author":"Shiradkar R","journal-title":"J Magn Reson Imaging"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eswa.2017.06.029"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1097\/RCT.0000000000000738"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13058-017-0846-1"},{"key":"e_1_2_9_30_1","doi-asserted-by":"crossref","first-page":"1236","DOI":"10.1118\/1.3081408","article-title":"Effects of MRI acquisition parameter variations and protocol heterogeneity on the results of texture analysis and pattern discrimination: an application\u2010oriented study","volume":"36","author":"Mayerhoefer ME","journal-title":"Med Phys"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5139"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-04151-4"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compmedimag.2015.04.006"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2003.09.001"},{"key":"e_1_2_9_35_1","unstructured":"The Cancer Imaging Archive: RIDER NEURO MRI.https:\/\/wiki.cancerimagingarchive.net\/display\/Public\/RIDER+NEURO+MRIAccessed Jan 21 2017."},{"key":"e_1_2_9_36_1","doi-asserted-by":"publisher","DOI":"10.1038\/sdata.2017.124"},{"key":"e_1_2_9_37_1","volume-title":"Image processing, analysis and machine vision","author":"Sonka M","year":"2008"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1109\/83.725367"},{"key":"e_1_2_9_39_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.2517-6161.1995.tb02031.x"},{"key":"e_1_2_9_40_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25088"},{"key":"e_1_2_9_41_1","doi-asserted-by":"publisher","DOI":"10.18383\/j.tom.2016.00208"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Facm2.12482","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.12482","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T11:06:04Z","timestamp":1694775964000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.12482"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,27]]},"references-count":40,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2018,11]]}},"alternative-id":["10.1002\/acm2.12482"],"URL":"https:\/\/doi.org\/10.1002\/acm2.12482","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10,27]]},"assertion":[{"value":"2018-06-30","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-09-24","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-10-27","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}