{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T14:39:26Z","timestamp":1790779166829,"version":"4.1.0"},"reference-count":31,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2018,12,26]],"date-time":"2018-12-26T00:00:00Z","timestamp":1545782400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2019,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>An effective radiotherapy treatment entails maximizing radiation dose to the tumor while sparing the surrounding and normal tissues. With the advent of <jats:styled-content style=\"fixed-case\">SBRT<\/jats:styled-content> with extreme hypo\u2010fractionation in treating tumors including prostate where ablative dose is delivered in smaller number of fractions, rectum remains a dose\u2010limiting organ and at the risk of rectal toxicity or secondary cancer. The same limitation of rectal toxicity exists for high\u2010dose rate (<jats:styled-content style=\"fixed-case\">HDR<\/jats:styled-content>) treatments of cervical, endometrial, or prostate cancer when creating even a short distance between the anterior rectal wall and field of radiation is ideal in delivering ablative dose to the target. An effective solution to such problem is to physically displace rectum as the organ at risk. This research presents an organ retractor device that is designed to displace the rectum away from the path of radiation beam employing a Nitinol shape memory alloy that is designed for displacing the rectum upon actuation. A control system regulates the motion in a reproducible and safe manner by creating the desirable shape in moving the anterior rectal wall. The study finds the novel organ retractor device to be a promising tool that can be applied in a clinical setting for minimizing dose to the rectum during treatment of pelvic tumors, and creating the potential to deliver an ablative dose to tumor volume or to escalate the dose when needed.<\/jats:p>","DOI":"10.1002\/acm2.12517","type":"journal-article","created":{"date-parts":[[2018,12,26]],"date-time":"2018-12-26T19:19:01Z","timestamp":1545851941000},"page":"194-199","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["A novel and innovative device to retract rectum during radiation therapy of pelvic tumors"],"prefix":"10.1002","volume":"20","author":[{"given":"E. Ishmael","family":"Parsai","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology University of Toledo Medical Center Toledo OH USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmadreza","family":"Jahadakbar","sequence":"additional","affiliation":[{"name":"Department of Mechanical Industrial and Manufacturing Engineering University of Toledo Toledo OH USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hossein","family":"Lavvafi","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology University of Toledo Medical Center Toledo OH USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad","family":"Elahinia","sequence":"additional","affiliation":[{"name":"Department of Mechanical Industrial and Manufacturing Engineering University of Toledo Toledo OH USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2018,12,26]]},"reference":[{"key":"e_1_2_6_2_1","volume-title":"Radiobiology for the Radiologist","author":"Hall EJ","year":"2006"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1038\/pcan.2015.4"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/cncr.28849"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2011.09.005"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2012.11.010"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v3i1.2590"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0958-3947(02)00092-4"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00066-007-1736-8"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-9-96"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2013.07.041"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1136\/bcr-2014-206931"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4889701"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4956690"},{"key":"e_1_2_6_15_1","doi-asserted-by":"crossref","DOI":"10.1002\/9781118426913","volume-title":"Shape Memory Alloy Actuators: Design, Fabrication, and Experimental Evaluation","author":"Elahinia M","year":"2015"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2007.905707"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmatprotec.2017.06.038"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmatprotec.2017.06.038"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.3390\/met8030164"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1155\/2011\/501483"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.3390\/bioengineering3040036"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/GOX.0000000000000859"},{"key":"e_1_2_6_23_1","unstructured":"JahadakbarA.The additively manufactured porous NiTi and Ti\u20106Al\u20104V in mandibular reconstruction: introducing the stiffness\u2010matched and the variable stiffness options for the reconstruction plates. 2016 University of Toledo."},{"key":"e_1_2_6_24_1","unstructured":"MoghaddamNS JahadakbarA ElahiniaM et\u00a0al.The effect of adding dental implants to the reconstructed mandible comparing the effect of using Ti\u20106Al\u20104V and NiTi hardware. In:Tissue Engineering Part A. 2015. Mary Ann Liebert Inc. 140 huguenot street 3rd Fl New Rochelle NY 10801 USA."},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.3390\/bioengineering4040095"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1201\/9781315151441-1"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2015.06.010"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmatprotec.2017.10.006"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.msea.2014.02.015"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pmatsci.2016.08.001"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.matchar.2007.02.007"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eururo.2005.06.001"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Facm2.12517","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.12517","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T18:59:46Z","timestamp":1694717986000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.12517"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12,26]]},"references-count":31,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,1]]}},"alternative-id":["10.1002\/acm2.12517"],"URL":"https:\/\/doi.org\/10.1002\/acm2.12517","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,12,26]]},"assertion":[{"value":"2017-12-06","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-11-13","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-12-26","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}