{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,25]],"date-time":"2025-07-25T11:01:58Z","timestamp":1753441318897,"version":"3.40.5"},"reference-count":26,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2020,8,10]],"date-time":"2020-08-10T00:00:00Z","timestamp":1597017600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2020,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The purpose of this study was to evaluate the effect of a hydrogel spacer on intrafractional prostate motion during CyberKnife treatment. The retrospective study enrolled 24 patients (with the hydrogel spacer\u00a0=\u00a012, without the hydrogel spacer\u00a0=\u00a012) with two fiducial markers. Regarding intrafractional prostate motion, the offset values (mm) of three axes (X\u2010axis; superior [+] to inferior [\u2212], Y\u2010axis; right [+] to left [\u2212], Z\u2010axis; posterior [+] to anterior [\u2212]) obtained from fiducial markers position between a digitally reconstructed radiographs images and live images in the Target Locating System were used, and extracted from generated log files. The mean values of the offset and each standard deviation were calculated for each patient, and both the groups were compared. For all the patients, a total of 2204 offset values and timestamps (without the hydrogel spacer group: 1065, with the hydrogel spacer group: 1139) were recorded for the X\u2010, Y\u2010, and Z\u2010axes, respectively. The offset values (mean\u00a0\u00b1\u00a0standard deviation) for the X\u2010, Y\u2010, and Z\u2010axes were \u22120.04\u00a0\u00b1\u00a00.92\u00a0mm, \u22120.03\u00a0\u00b1\u00a00.97\u00a0mm (<jats:italic>P<\/jats:italic>\u00a0=\u00a00.66), 0.02\u00a0\u00b1\u00a00.51, \u22120.02\u00a0\u00b1\u00a00.49\u00a0mm (<jats:italic>P<\/jats:italic>\u00a0=\u00a00.50), and 0.56\u00a0\u00b1\u00a00.97\u00a0mm, 0.34\u00a0\u00b1\u00a01.07\u00a0mm (<jats:italic>P<\/jats:italic>\u00a0=\u00a00.14), in patients inserted without or with the hydrogel spacer, respectively. There was no effect of a hydrogel spacer on the intrafractional prostate motion in the three axes during CyberKnife treatment for prostate cancer.<\/jats:p>","DOI":"10.1002\/acm2.13005","type":"journal-article","created":{"date-parts":[[2020,8,10]],"date-time":"2020-08-10T09:21:36Z","timestamp":1597051296000},"page":"63-68","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Effect of a hydrogel spacer on the intrafractional prostate motion during CyberKnife treatment for prostate cancer"],"prefix":"10.1002","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0414-5218","authenticated-orcid":false,"given":"Toshihiro","family":"Suzuki","sequence":"first","affiliation":[{"name":"Kasugai CyberKnife Rehabilitation Hospital Yamanashi Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8636-4045","authenticated-orcid":false,"given":"Masahide","family":"Saito","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Yamanashi Yamanashi Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Onishi","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Yamanashi Yamanashi Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zennosuke","family":"Mochizuki","sequence":"additional","affiliation":[{"name":"Kasugai CyberKnife Rehabilitation Hospital Yamanashi Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji","family":"Mochizuki","sequence":"additional","affiliation":[{"name":"Kasugai CyberKnife Rehabilitation Hospital Yamanashi Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenichiro","family":"Satani","sequence":"additional","affiliation":[{"name":"Kasugai CyberKnife Rehabilitation Hospital Yamanashi Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoki","family":"Sano","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Yamanashi Yamanashi Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinichi","family":"Aoki","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Yamanashi Yamanashi Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kan","family":"Marino","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Yamanashi Yamanashi Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takafumi","family":"Komiyama","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Yamanashi Yamanashi Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Takahashi","sequence":"additional","affiliation":[{"name":"Kasugai CyberKnife Rehabilitation Hospital Yamanashi Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2020,8,10]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-8140(99)00100-0"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-8-58"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-9-42"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1177\/153303460300200104"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2003.10.011"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1001\/jamaoncol.2018.0039"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2490-10-1"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(98)00091-1"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2007.11.044"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(02)03742-2"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2015.04.030"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2011.09.005"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1093\/jrr\/rraa013"},{"key":"e_1_2_7_15_1","first-page":"e3523","article-title":"Evaluation of CyberKnife(R) fiducial tracking limitations to assist targeting accuracy: a phantom study with fiducial displacement","volume":"10","author":"Goldsmith C","year":"2018","journal-title":"Cureus"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1470-2045(19)30569-8"},{"key":"e_1_2_7_17_1","first-page":"203","article-title":"Analysis of intrafraction motion in CyberKnife\u2010based stereotaxy using mask based immobilization and 6D\u2010skull tracking","volume":"4","author":"Kataria T","year":"2016","journal-title":"J Radiosurg SBRT"},{"key":"e_1_2_7_18_1","first-page":"217","article-title":"Reducing errors in prostate tracking with an improved fiducial implantation protocol for CyberKnife based stereotactic body radiotherapy (SBRT)","volume":"5","author":"Holmes OE","year":"2018","journal-title":"J Radiosurg SBRT"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2011.00048"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2008.04.051"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-9-186"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(01)01453-5"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2012.04.005"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2011.07.028"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.3109\/0284186X.2015.1128118"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2012.11.010"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-015-0526-1"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Facm2.13005","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.13005","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/acm2.13005","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.13005","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T05:10:04Z","timestamp":1693545004000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.13005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,10]]},"references-count":26,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2020,10]]}},"alternative-id":["10.1002\/acm2.13005"],"URL":"https:\/\/doi.org\/10.1002\/acm2.13005","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"type":"print","value":"1526-9914"},{"type":"electronic","value":"1526-9914"}],"subject":[],"published":{"date-parts":[[2020,8,10]]},"assertion":[{"value":"2020-05-21","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-07-23","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-08-10","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}