{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T13:41:14Z","timestamp":1794490874647,"version":"4.9.1"},"reference-count":20,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2021,3,19]],"date-time":"2021-03-19T00:00:00Z","timestamp":1616112000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2021,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>Studies have evaluated the viability of using open\u2010face masks as an immobilization technique to treat intracranial and head and neck cancers. This method offers less stress to the patient with comparable accuracy to closed\u2010face masks. Open\u2010face masks permit implementation of surface guided radiation therapy (SGRT) to assist in positioning and motion management. Research suggests that changes in patient facial expressions may influence the SGRT system to generate false positional corrections. This study aims to quantify these errors produced by the SGRT system due to face motion.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Ten human subjects were immobilized using open\u2010face masks. Four discrete SGRT regions of interest (ROIs) were analyzed based on anatomical features to simulate different mask openings. The largest ROI was lateral to the cheeks, superior to the eyebrows, and inferior to the mouth. The smallest ROI included only the eyes and bridge of the nose. Subjects were asked to open and close their eyes and simulate fear and annoyance and peak isocenter shifts were recorded. This was performed in both standard and SRS specific resolutions with the C\u2010RAD Catalyst HD system.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>All four ROIs analyzed in SRS and Standard resolutions demonstrated an average deviation of 0.3\u00a0\u00b1\u00a00.3\u00a0mm for eyes closed and 0.4\u00a0\u00b1\u00a00.4\u00a0mm shift for eyes open, and 0.3\u00a0\u00b1\u00a00.3\u00a0mm for eyes closed and 0.8\u00a0\u00b1\u00a00.9\u00a0mm shift for eyes open. The average deviation observed due to changing facial expressions was 1.4\u00a0\u00b1\u00a00.9\u00a0mm for SRS specific and 1.6\u00a0\u00b1\u00a01.6\u00a0mm for standard resolution.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The SGRT system can generate false positional corrections for face motion and this is amplified at lower resolutions and smaller ROIs. These errors should be considered in the overall tolerances and treatment plan when using open\u2010face masks with SGRT and may warrant additional radiographic imaging.<\/jats:p><\/jats:sec>","DOI":"10.1002\/acm2.13170","type":"journal-article","created":{"date-parts":[[2021,3,19]],"date-time":"2021-03-19T09:49:14Z","timestamp":1616147354000},"page":"172-183","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":30,"title":["Quantifying false positional corrections due to facial motion using SGRT with open\u2010face Masks"],"prefix":"10.1002","volume":"22","author":[{"given":"Victoria","family":"Bry","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology School of Medicine The University of Texas Health Science Center at San Antonio San Antonio TX 78229 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna Laura","family":"Licon","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology School of Medicine The University of Texas Health Science Center at San Antonio San Antonio TX 78229 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"McCulloch","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology School of Medicine The University of Texas Health Science Center at San Antonio San Antonio TX 78229 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Neil","family":"Kirby","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology School of Medicine The University of Texas Health Science Center at San Antonio San Antonio TX 78229 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pamela","family":"Myers","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology School of Medicine The University of Texas Health Science Center at San Antonio San Antonio TX 78229 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Saenz","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology School of Medicine The University of Texas Health Science Center at San Antonio San Antonio TX 78229 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sotirios","family":"Stathakis","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology School of Medicine The University of Texas Health Science Center at San Antonio San Antonio TX 78229 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niko","family":"Papanikolaou","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology School of Medicine The University of Texas Health Science Center at San Antonio San Antonio TX 78229 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl","family":"Rasmussen","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology School of Medicine The University of Texas Health Science Center at San Antonio San Antonio TX 78229 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2021,3,19]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2008.11.015"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.4103\/0028-3886.115068"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2010.06.022"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v14i5.4400"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/pon.1854"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/55\/7\/005"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/0360-3016(82)90530-2"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2011.10.012"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12183"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3596526"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prro.2011.04.005"},{"key":"e_1_2_7_13_1","first-page":"137","article-title":"Direct comparison between surface imaging and orthogonal radiographic imaging for SRS localization in phantom","volume":"20","author":"Wiant D","year":"2019","journal-title":"J Appli Med Phys"},{"key":"e_1_2_7_14_1","first-page":"E567","article-title":"Comparing the accuracy of surface guided imaging to orthogonal X\u2010rays for stereotactic radiosurgery","volume":"46","author":"Bry V","year":"2019","journal-title":"Med Phys"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3483783"},{"issue":"2","key":"e_1_2_7_16_1","first-page":"128","article-title":"Structured\u2010light 3D surface imaging: a tutorial","volume":"3","author":"Geng J","year":"2011","journal-title":"IEEE Intelligent Transportation System Society"},{"key":"e_1_2_7_17_1","volume-title":"\"Technical Overview and Features of the C\u2010RAD Catalyst and Sentinel 4D\u2010CT Systems,\" in Surface Guided Radiation Therapy","author":"Rasmussen K","year":"2020"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v17i5.6041"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.rpor.2011.04.005"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmrs.208"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4953192"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.13170","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/acm2.13170","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.13170","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T18:37:57Z","timestamp":1693593477000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.13170"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,19]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021,4]]}},"alternative-id":["10.1002\/acm2.13170"],"URL":"https:\/\/doi.org\/10.1002\/acm2.13170","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,19]]},"assertion":[{"value":"2020-08-10","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-12-25","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-03-19","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}