{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,12]],"date-time":"2026-05-12T06:27:19Z","timestamp":1778567239067,"version":"3.51.4"},"reference-count":25,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2021,8,26]],"date-time":"2021-08-26T00:00:00Z","timestamp":1629936000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>This study aims to verify the dose delivery of prostate radiotherapy treatments in an adult pelvic phantom with two metallic hip and femur prosthesis using a four\u2010field box technique. The prostate planned target volume (PTV) tridimensional (3D) dose distribution was evaluated using gel dosimetry, and thermoluminescent dosimeters (TLD) were used for point\u2010dose measurements outside it. Both results were compared to the treatment planning system (TPS) dose calculation without using heterogeneity corrections to evaluate the influence of the metal in the dose distribution. MAGIC\u2010f gel dosimeter (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper with Formaldehyde) associated with magnetic resonance imaging was used. TLD were positioned at several points at the bone metal interface and the sacrum region. The comparison of the gel measured and the TPS calculated dose distributions were done using gamma analysis (3%\/3\u00a0mm), and a pass rate of 93% was achieved. The TLD dose values at the bone\u2010metal interface showed variations from the planned dose. However, at the sacrum region, where the beams did not intercept the prosthesis, there was a good agreement between TPS planning and TLD measurements. Our results show how the combination of 3D dosimetry and measurements at specific points in the phantom allowed a comprehensive view of the dose distribution and identified that care must also be paid to regions outside the PTV.<\/jats:p>","DOI":"10.1002\/acm2.13403","type":"journal-article","created":{"date-parts":[[2021,8,26]],"date-time":"2021-08-26T13:39:35Z","timestamp":1629985175000},"page":"278-287","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Gel and thermoluminescence dosimetry for dose verifications of a real anatomy simulated prostate conformal radiation treatment in the presence of metallic femoral prosthesis"],"prefix":"10.1002","volume":"22","author":[{"given":"Diana M. C.","family":"Rojas","sequence":"first","affiliation":[{"name":"Department of Physics Faculty of Philosophy, Sciences, and Letters University of S\u00e3o Paulo  Ribeir\u00e3o Preto Sao Paulo Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juliana F.","family":"Pavoni","sequence":"additional","affiliation":[{"name":"Department of Physics Faculty of Philosophy, Sciences and Letters, University of S\u00e3o Paulo  Ribeir\u00e3o Preto Sao Paulo Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gustavo V.","family":"Arruda","sequence":"additional","affiliation":[{"name":"Ribeir\u00e3o Preto Medical School, University of S\u00e3o Paulo  Ribeir\u00e3o Preto Sao Paulo Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oswaldo","family":"Baffa","sequence":"additional","affiliation":[{"name":"Department of Physics Faculty of Philosophy, Sciences and Letters, University of S\u00e3o Paulo  Ribeir\u00e3o Preto Sao Paulo Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2021,8,26]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1440-1673.2000.00816.x"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.1565113"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/48\/20\/003"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(01)02592-5"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12141"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa5293"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.596345"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/0360-3016(91)90210-U"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0969-8043(02)00078-7"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/0360-3016(88)90412-9"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4967483"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12060"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/55\/5\/R01"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/53\/4\/N04"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4704496"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2016.12.007"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.12400"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2012.10.004"},{"key":"e_1_2_10_20_1","volume-title":"Thermoluminescence Dosimetry Materials: Properties and Uses","author":"McKeever S","year":"1995"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.598248"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.3109\/17453674.2014.963784"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0958-3947(02)00245-5"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12167"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/48\/11\/308"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2017.09.029"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.13403","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/acm2.13403","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.13403","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T17:16:33Z","timestamp":1693242993000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.13403"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,26]]},"references-count":25,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2021,10]]}},"alternative-id":["10.1002\/acm2.13403"],"URL":"https:\/\/doi.org\/10.1002\/acm2.13403","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,8,26]]},"assertion":[{"value":"2020-09-23","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-08-30","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-08-26","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}