{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T18:29:57Z","timestamp":1791570597256,"version":"4.3.4"},"reference-count":20,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2023,1,12]],"date-time":"2023-01-12T00:00:00Z","timestamp":1673481600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2023,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Radixact Synchrony<jats:sup>\u00ae<\/jats:sup>, a real\u2010time motion tracking and compensating modality, is used for helical tomotherapy. Control parameters are used for the accurate application of irradiation. Radixact Synchrony<jats:sup>\u00ae<\/jats:sup> uses the potential difference, which is an index of the accuracy of the prediction model of target motion and is represented by a statistical prediction of the 3D distance error. Although there are several reports on Radixact Synchrony<jats:sup>\u00ae<\/jats:sup>, few have reported the appropriate settings of the potential difference threshold.<\/jats:p><\/jats:sec><jats:sec><jats:title>Purpose<\/jats:title><jats:p>This study aims to determine the optimal threshold of the potential difference of Radixact Synchrony<jats:sup>\u00ae<\/jats:sup> during respiratory tumor\u2010motion\u2010tracking irradiation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The relationship among the dosimetric accuracy, motion tracking accuracy, and control parameter was evaluated using a moving platform, a phantom with a basic respiratory model (the fourth power of a sinusoidal wave), and several irregular respiratory model waveforms. The dosimetric accuracy was evaluated by gamma analysis (3%, 1\u00a0mm, 10% dose threshold). The tracking accuracy was measured by the distance error of the difference between the tracked and driven positions of the phantom. The largest potential difference for 95% of treatment time was evaluated, and its correlation with the gamma\u2010pass ratio and distance error was investigated. The optimal threshold of the potential difference was determined by receiver operating characteristic (ROC) analysis.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>A linear correlation was identified between the potential difference and the gamma\u2010pass ratio (R\u00a0=\u00a0\u20130.704). A linear correlation was also identified between the potential difference and distance error (R\u00a0=\u00a00.827). However, as the potential difference increased, it tended to underestimate the distance error. The ROC analysis revealed that the appropriate cutoff value of the potential difference was 3.05\u00a0mm.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The irradiation accuracy with motion tracking by Radixact Synchrony<jats:sup>\u00ae<\/jats:sup> could be predicted from the potential difference, and the threshold of the potential difference should be set to \u223c3\u00a0mm.<\/jats:p><\/jats:sec>","DOI":"10.1002\/acm2.13901","type":"journal-article","created":{"date-parts":[[2023,1,13]],"date-time":"2023-01-13T04:44:55Z","timestamp":1673585095000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Optimal threshold of a control parameter for tomotherapy respiratory tracking: A phantom study"],"prefix":"10.1002","volume":"24","author":[{"given":"Keisuke","family":"Sano","sequence":"first","affiliation":[{"name":"Department of Radiology Hyogo Medical University  Nishinomiya Hyogo Japan"},{"name":"Department of Radiotherapy Takarazuka City Hospital  Takarazuka Hyogo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masayuki","family":"Fujiwara","sequence":"additional","affiliation":[{"name":"Department of Radiology Hyogo Medical University  Nishinomiya Hyogo Japan"},{"name":"Department of Radiotherapy Takarazuka City Hospital  Takarazuka Hyogo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wataru","family":"Okada","sequence":"additional","affiliation":[{"name":"Department of Radiology Hyogo Medical University  Nishinomiya Hyogo Japan"},{"name":"Department of Radiotherapy Takarazuka City Hospital  Takarazuka Hyogo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masao","family":"Tanooka","sequence":"additional","affiliation":[{"name":"Department of Radiology Hyogo Medical University  Nishinomiya Hyogo Japan"},{"name":"Department of Radiotherapy Takarazuka City Hospital  Takarazuka Hyogo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haruyuki","family":"Takaki","sequence":"additional","affiliation":[{"name":"Department of Radiology Hyogo Medical University  Nishinomiya Hyogo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mayuri","family":"Shibata","sequence":"additional","affiliation":[{"name":"Department of Radiotherapy Takarazuka City Hospital  Takarazuka Hyogo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenji","family":"Nakamura","sequence":"additional","affiliation":[{"name":"Department of Radiotherapy Takarazuka City Hospital  Takarazuka Hyogo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusuke","family":"Sakai","sequence":"additional","affiliation":[{"name":"Department of Radiotherapy Takarazuka City Hospital  Takarazuka Hyogo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hitomi","family":"Suzuki","sequence":"additional","affiliation":[{"name":"Department of Radiology Hyogo Medical University  Nishinomiya Hyogo Japan"},{"name":"Department of Radiotherapy Takarazuka City Hospital  Takarazuka Hyogo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kanae","family":"Takahashi","sequence":"additional","affiliation":[{"name":"Department of Biostatistics Hyogo Medical University  Nishinomiya Hyogo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahiro","family":"Tanaka","sequence":"additional","affiliation":[{"name":"Department of Radiotherapy Takarazuka City Hospital  Takarazuka Hyogo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koichiro","family":"Yamakado","sequence":"additional","affiliation":[{"name":"Department of Radiology Hyogo Medical University  Nishinomiya Hyogo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2023,1,12]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.596958"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v7i4.2222"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/54\/19\/004"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2349696"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.12791"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1177\/2050313X211023688"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.14171"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12978"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.12810"},{"issue":"2","key":"e_1_2_9_11_1","first-page":"135","article-title":"Application of TG\u2010218 action limits to SRS and SBRT pre\u2010treatment patient specific QA","volume":"7","author":"Xia Y","year":"2020","journal-title":"J radiosurgery SBRT"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.14153"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13438"},{"key":"e_1_2_9_14_1","unstructured":"AccurayI.Physics Essentials Guide Version 3.0.x 2021."},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcm.2016.02.012"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2015.09.024"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/s13246-014-0310-9"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2006.10.007"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2011.02.048"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.13523"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.15667"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.13901","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/acm2.13901","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.13901","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,21]],"date-time":"2023-08-21T03:08:43Z","timestamp":1692587323000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.13901"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,12]]},"references-count":20,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023,5]]}},"alternative-id":["10.1002\/acm2.13901"],"URL":"https:\/\/doi.org\/10.1002\/acm2.13901","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,12]]},"assertion":[{"value":"2022-09-28","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-12-28","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-01-12","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e13901"}}