{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T07:38:40Z","timestamp":1768289920416,"version":"3.49.0"},"reference-count":26,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2024,9,16]],"date-time":"2024-09-16T00:00:00Z","timestamp":1726444800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2024,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>Total skin electron therapy (TSET) is a complex radiotherapy technique, posing challenges in commissioning and quality assurance (QA), especially due to significant variability in patient body shapes. Previous studies have correlated dose with factors such as obesity index, height, and gender. However, current treatment planning systems cannot simulate TSET plans, necessitating heavy reliance on QA methods using standardized anthropomorphic phantoms and in\u2010vivo dosimetry. Given the relatively few studies on rotational techniques, comprehensive data in commissioning could streamline the process.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Developing a full\u2010body phantom would enable a more thorough TSET commissioning process, including testing for position\u2010specific dose distributions and comprehensive measurements across all body surfaces, unlike the typical torso\u2010only phantoms. This was created using digital modeling software, fabricated using 3D\u2010printing FDM technology, and filled with tissue\u2010equivalent gelatine. The phantom was positioned at an SSD of 340\u00a0cm and irradiated with a standard rotational TSET plan using the 6E HDTSE mode on a Varian TrueBeam linac at gantry angles of\u00a0\u00b1\u00a018\u00b0 from the horizontal. The dose was measured at over 50 points across the surface using Gafchromic EBT3 film.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Dose distributions were generally consistent with existing literature values from in\u2010vivo dosimetry, with several position\u2010specific differences identified, including the hands and scalp compared to conventional positions. Hotspots were observed for the mid\u2010dorsum of the foot and nose, with areas under 80% of the dose identified as the soles of the feet, perineum, vertex of the scalp, top of the shoulder, and palm of the hand. Additionally, analysis using an interpolated dose heatmap found that 90% of the pixel area received a dose within 10% of the prescribed dose, indicating good uniformity with the commissioned technique.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>With high agreement with the current literature, a 3D\u2010printed phantom proves effective for measuring doses in areas typically unmeasurable in TSET commissioning.<\/jats:p><\/jats:sec>","DOI":"10.1002\/acm2.14520","type":"journal-article","created":{"date-parts":[[2024,9,17]],"date-time":"2024-09-17T04:25:10Z","timestamp":1726547110000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Development of a 3D\u2010printed phantom for total skin electron therapy dose assessment"],"prefix":"10.1002","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-8345-3422","authenticated-orcid":false,"given":"Andrew","family":"Lee","sequence":"first","affiliation":[{"name":"School of Physics, Mathematics and Computing The University of Western Australia Crawley WA Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zaid","family":"Alkhatib","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Sir Charles Gairdner Hospital Nedlands WA Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mounir","family":"Ibrahim","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Sir Charles Gairdner Hospital Nedlands WA Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Broderick","family":"McCallum\u2010Hee","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Sir Charles Gairdner Hospital Nedlands WA Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joshua","family":"Dass","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Sir Charles Gairdner Hospital Nedlands WA Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthew","family":"Fernandez de Viana","sequence":"additional","affiliation":[{"name":"School of Physics, Mathematics and Computing The University of Western Australia Crawley WA Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pejman","family":"Rowshanfarzad","sequence":"additional","affiliation":[{"name":"School of Physics, Mathematics and Computing The University of Western Australia Crawley WA Australia"},{"name":"Centre for Advanced Technologies in Cancer Research (CATCR) Perth Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2024,9,16]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejca.2017.02.027"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2010.09.001"},{"key":"e_1_2_9_4_1","doi-asserted-by":"crossref","unstructured":"LuceroJF RojasJI.Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high\u2010dose total skin electron mode.AIP Conf. Proc. Selected articles from the Latin American Symposium on Nuclear Physics and Applications (LASNPA 2015).2016;1753:1. doi:10.1063\/1.4955387","DOI":"10.1063\/1.4955387"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.4103\/jcrt.jcrt_2355_22"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365\u20104632.2005.02217.x"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1259\/bjro.20190008"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.5114\/pdia.2013.33379"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.adro.2016.03.005"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.adro.2021.100698"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361\u20106560\/abedd7"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmir.2022.08.006"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.rpor.2013.07.011"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360\u20103016(97)00585\u20103"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.phro.2018.05.002"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s13246\u2010015\u20100371\u20104"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1017\/S1460396919000591"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v17i4.6230"},{"key":"e_1_2_9_19_1","unstructured":"BasagliaT BoccacciP ChauvieS et\u00a0al.Total skin electron therapy stanford technique evolution with Monte Carlo simulation toward personalized treatments for cutaneous lymphoma.arXivorg. Selected articles from the 2022 IEEE Nuclear Science Symposium (NSS).2023.doi:10.48550\/arXiv.2311.10684"},{"key":"e_1_2_9_20_1","unstructured":"Australian Bureau of Statistics. 4338.0 \u2010 Profiles of Health Australia 2011\u201313 29\/10\/2012. Accessed July 3 2023.https:\/\/www.abs.gov.au\/ausstats\/abs@.nsf\/Lookup\/4338.0main+features212011\u201013"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1109\/TDEI.2016.006029"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.4103\/jmp.jmp_72_22"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.rpor.2019.12.011"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1507\u20101367(06)71047\u20101"},{"key":"e_1_2_9_25_1","volume-title":"Radiation Oncology Physics: A Handbook For Teachers and Students","author":"Podgors\u030cak EB","year":"2005"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1067\/mjd.2002.123482"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1080\/09546634.2021.1906398"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.14520","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,25]],"date-time":"2025-08-25T16:44:01Z","timestamp":1756140241000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.14520"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,16]]},"references-count":26,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2024,12]]}},"alternative-id":["10.1002\/acm2.14520"],"URL":"https:\/\/doi.org\/10.1002\/acm2.14520","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,16]]},"assertion":[{"value":"2024-05-06","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-08-06","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-09-16","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e14520"}}