{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T04:32:19Z","timestamp":1791088339271,"version":"4.1.0"},"reference-count":46,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2025,3,3]],"date-time":"2025-03-03T00:00:00Z","timestamp":1740960000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose\/objectives<\/jats:title>\n                    <jats:p>Recent technological advancements have increased efficiency for clinical deliverability of online\u2010adaptive\u2010radiotherapy (oART). Previous cone\u2010beam\u2010computed\u2010tomography (CBCT) generations lacked the ability to provide reliable Hounsfield\u2010units (HU), thus requiring oART workflows to rely on synthetic\u2010CT (sCT) images derived through deformable\u2010image\u2010registration (DIR) between the planning CT (pCT) and the daily CBCT. These sCTs are prone to errors stemming from DIR, potentially contributing to dosimetric errors. This study aims to evaluate the capability of direct dose calculation using a novel CBCT platform, HyperSight (Varian\u2010Medical\u2010Systems), as an alternative for sCT.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods\/materials<\/jats:title>\n                    <jats:p>To validate the HyperSight iterative CBCT (HS\u2010iCBCT) HU accuracy, 125\u00a0kV and 140\u00a0kV HS\u2010iCBCT calibration curves were benchmarked against a pCT calibration curve. To determine the clinical impact of HS\u2010iCBCT compared to sCT, daily adaptive sessions from 47 oART fractions from 10 patients were analyzed. For these patients, HS\u2010iCBCT was acquired for daily adaption, and sCT was generated as part of the standard adaptive workflow. After daily adaption, dose was recalculated directly using the HS\u2010iCBCT, and the HS\u2010iCBCT and sCT dose distributions were compared by \u03b3\u2010index and dose\u2010volume\u2010histogram (DVH) analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The mean HU differences of pCT minus HS\u2010iCBCT (140\/125\u00a0kV) were \u221240.97\/\u221257.79, 9.86\/21.74, and 87.22\/158.20 for lung, water, and bone. In the patient cohort, the median gamma passing rates between HS\u2010iCBCT and sCT\u2010based dose calculations for 3%\/2\u00a0mm and 1%\/1\u00a0mm were 99.57 and 96.45% with 10% threshold, and 99.92% and 86.15% with 80% threshold. Dosimetric deviations in high dose regions were concentrated in areas with larger deformation, that is, surface change and variable bladder\/bowel filling. The median (min\u2010max) D98%\/V100% absolute deviations were 0.3(0.0\u20131.6)\/0.0(0.0\u201313.7) and 0.4(0.0\u20131.4)\/0.5(0.0\u201317.5) for CTVs and PTVs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The HS\u2010iCBCT platform with iterative reconstruction provides dose calculation comparable to sCT for pelvis and breast patients. However, acceptable, yet noticeable, dose discrepancies between HS\u2010iCBCT and sCT exist, particularly in high\u2010dose regions. Further investigations are needed to benchmark these methods against ground truth measurements.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/acm2.70038","type":"journal-article","created":{"date-parts":[[2025,3,11]],"date-time":"2025-03-11T17:02:39Z","timestamp":1741712559000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":25,"title":["Assessing HyperSight iterative CBCT for dose calculation in online adaptive radiotherapy for pelvis and breast patients compared to synthetic CT"],"prefix":"10.1002","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6551-9127","authenticated-orcid":false,"given":"Jingwei","family":"Duan","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology University of Alabama at Birmingham Birmingham USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4450-6698","authenticated-orcid":false,"given":"Joel A.","family":"Pogue","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology University of Alabama at Birmingham Birmingham USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4792-748X","authenticated-orcid":false,"given":"Dennis N.","family":"Stanley","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology University of Alabama at Birmingham Birmingham USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sui","family":"Shen","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology University of Alabama at Birmingham Birmingham USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Natalie N.","family":"Viscariello","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology University of Alabama at Birmingham Birmingham USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos E.","family":"Cardenas","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology University of Alabama at Birmingham Birmingham USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1252-738X","authenticated-orcid":false,"given":"Richard A.","family":"Popple","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology University of Alabama at Birmingham Birmingham USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2441-9853","authenticated-orcid":false,"given":"Joseph","family":"Harms","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology University of Alabama at Birmingham Birmingham USA"},{"name":"Department of Radiation Oncology Washington University School of Medicine Saint Louis Missouri US"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,3,3]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2017.04.023"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.adro.2025.101740"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13479"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-020-01641-0"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.adro.2023.101414"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13425"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13961"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-022-02125-z"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2022.06.078"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2024.110178"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14134"},{"key":"e_1_2_10_13_1","unstructured":"OttossonW SiboltP Uncertainties in the use of synthetic CT (sCT) for daily online adaptive radiotherapy for lung cancer Vivika Johansson."},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.12256"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13801"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14311"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2023.102662"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/52\/3\/011"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2006.08.031"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2020.06.017"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/54\/20\/013"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-5-29"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-3-42"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4964455"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.14121"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac01b6"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.13978"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.13656"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4820537"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.4103\/2231-0762.170523"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3397460"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-023-02340-2"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prro.2023.10.014"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2021.05.027"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2020.109293"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-8140(23)66583-1"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.phro.2024.100566"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad3cb0"},{"key":"e_1_2_10_39_1","unstructured":"Gamma Calculation Algorithm From GitHub. Available fromhttps:\/\/github.com\/mwgeurts\/gamma\/tree\/master"},{"key":"e_1_2_10_40_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.12810"},{"issue":"8","key":"e_1_2_10_41_1","article-title":"Enhancing precision in radiation therapy for locally advanced lung cancer: a case study of cone\u2010beam computed tomography (cbct)\u2010based online adaptive techniques and the promise of HyperSight\u2122 iterative CBCT","volume":"16","author":"Duan J","year":"2024","journal-title":"Cureus"},{"key":"e_1_2_10_42_1","article-title":"Radiation dosimetry changes in radiotherapy treatment plans for adult patients arising from the selection of the CT image reconstruction kernel","volume":"1","author":"Davis AT","year":"2020","journal-title":"BJR| Open"},{"key":"e_1_2_10_43_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12167"},{"key":"e_1_2_10_44_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.12251"},{"key":"e_1_2_10_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2024.110596"},{"key":"e_1_2_10_46_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13399"},{"key":"e_1_2_10_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tipsro.2024.100242"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.70038","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,8]],"date-time":"2025-05-08T02:29:01Z","timestamp":1746671341000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.70038"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,3]]},"references-count":46,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["10.1002\/acm2.70038"],"URL":"https:\/\/doi.org\/10.1002\/acm2.70038","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,3]]},"assertion":[{"value":"2024-06-11","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-02","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-03-03","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70038"}}