{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T14:26:34Z","timestamp":1781706394408,"version":"3.54.5"},"reference-count":38,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2025,3,2]],"date-time":"2025-03-02T00:00:00Z","timestamp":1740873600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>The aim of this study was to investigate the influence of the simultaneous multislice acceleration (SMS) technique as well as two\u2010dimensional (2D) and three\u2010dimensional (3D) tumor segmentations on radiomics features (RFs) within the parametric maps of cervical cancer, which were computed by intravoxel incoherent motion (IVIM) and diffusion kurtosis imaging (DKI). Additionally, the study sought to identify those RFs that could characterize the clinical stages (low\u2010stage vs. high\u2010stage) of cervical cancer.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and methods<\/jats:title><jats:p>Multi\u2010<jats:italic>b<\/jats:italic>\u2010value diffusion\u2010weighted imaging (DWI) of 40 patients with cervical cancer were collected using the SMS technique with acceleration factors (AF) of 1\u20133. RFs were extracted from parametric maps representing pure diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), mean diffusivity (MD), and mean kurtosis (MK). A total of 93 2D and 93 3D RFs were extracted from per parametric map. The concordance correlation coefficient (CCC) and coefficients of variation (COV) were used to jointly assess the stability of features. Finally, the intra\u2010class correlation coefficient (ICC) was used for intra\u2010group consistency assessment. Receiver operating characteristic (ROC) curve was used to evaluate diagnostic performance of stable features in distinguishing lower and higher stages.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Feature stability decreased with higher AF. Among these features, 9.1% of 2D and 12.7% of 3D RFs were stable (CCC\u00a0&gt;\u00a00.9 and COV\u00a0\u2264\u00a00.1). ADC maps had the highest stability, whileas D<jats:sup>*<\/jats:sup> and f maps had the lowest stability and 3D features were more stable than 2D features. A total of 5 2D and 25 3D stable features were identified that could distinguish lower and higher stages (AUC\u00a0=\u00a00.66\u20130.83).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>SMS demonstrated impact on the stability of RFs in IVIM and DKI parametric maps, particularly for D* and f maps. Multi\u2010<jats:italic>b<\/jats:italic>\u2010value DWI with SMS (AF\u00a0=\u00a02) was recommended for clinical radiomics research.<\/jats:p><\/jats:sec>","DOI":"10.1002\/acm2.70063","type":"journal-article","created":{"date-parts":[[2025,3,12]],"date-time":"2025-03-12T05:36:54Z","timestamp":1741757814000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Effects of simultaneous multislice acceleration on the stability of radiomics features in parametric maps of IVIM and DKI in uterine cervical cancer"],"prefix":"10.1002","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-7334-0581","authenticated-orcid":false,"given":"Shuangquan","family":"Ai","sequence":"first","affiliation":[{"name":"Department of Radiology Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology  Wuhan China"},{"name":"College of Biomedical Engineering South\u2010Central Minzu University  Wuhan Hubei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Peng","sequence":"additional","affiliation":[{"name":"Department of Radiology Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology  Wuhan China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rong","family":"Hou","sequence":"additional","affiliation":[{"name":"Department of Patholoogy Suizhou Hospital Affiliated to Hubei Medical College  Shiyan Hubei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huiting","family":"Zhang","sequence":"additional","affiliation":[{"name":"MR Scientific Marketing, Siemens Healthineers  Wuhan China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Grimm","sequence":"additional","affiliation":[{"name":"MR Application Predevelopment, Siemens Healthcare GmbH  Erlangen Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5856-6208","authenticated-orcid":false,"given":"Zilong","family":"Yuan","sequence":"additional","affiliation":[{"name":"Department of Radiology Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology  Wuhan China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yulin","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Radiology Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology  Wuhan China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,3,2]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.3322\/caac.21492"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.180.6.1801621"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1136\/ijgc-2020-001257"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00261-020-02586-4"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1177\/02841851211002017"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2017.10.016"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2022.05.005"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2021.08.018"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2019.06.022"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2022.08.002"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1155\/2018\/1729071"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.3348\/kjr.2019.0406"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2015.10.009"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1593\/neo.81328"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/RCT.0000000000001189"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00062-015-0469-9"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1177\/0284185119870157"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.28521"},{"issue":"8","key":"e_1_2_10_20_1","first-page":"9182","article-title":"T2\u2010FLAIR, DWI and DKI radiomics satisfactorily predicts histological grade and Ki\u201067 proliferation index in gliomas","volume":"13","author":"Su C","year":"2021","journal-title":"Am J Transl Res"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2019.108785"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12967-021-03117-5"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11547-022-01468-7"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.28027"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2019.08.008"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.crad.2020.06.024"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2017161375"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2022.1016123"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1038\/srep23428"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-021-08251-8"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.27444"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-020-07612-z"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2022.03.002"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-020-06913-7"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25897"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25519"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00429-020-02053-2"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20643"},{"issue":"2","key":"e_1_2_10_39_1","first-page":"96","article-title":"Simultaneous multi\u2010slice\u2014a concise review covering major applications in clinical practice","volume":"68","author":"Runge V","year":"2017","journal-title":"Clinical Oncological Imaging"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.70063","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,8]],"date-time":"2025-05-08T06:29:45Z","timestamp":1746685785000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.70063"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,2]]},"references-count":38,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["10.1002\/acm2.70063"],"URL":"https:\/\/doi.org\/10.1002\/acm2.70063","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,2]]},"assertion":[{"value":"2024-07-03","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-23","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-03-02","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70063"}}