{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T20:23:20Z","timestamp":1773001400378,"version":"3.50.1"},"reference-count":17,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T00:00:00Z","timestamp":1749081600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T00:00:00Z","timestamp":1749081600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Four\u2010dimensional cone\u2010beam CT (4D CBCT) incorporates oversampling of 3D data to reconstruct multi\u2010phase CBCT data sets representing distinct phases of the breathing cycle based on a diaphragmatic correlate of respiratory motion. Motion artifacts and blurring can be reduced relative to three\u2010dimensional cone\u2010beam (3D CBCT), allowing clinicians to better visualize motion of targets. To quantitatively understand the degree to which target visualization is improved by 4D CBCT, an edge visualization metric (EVM) has been developed to describe the change in voxel intensities at the edge of targets in 4D CBCT maximum intensity projection images relative to 3D CBCT images.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The EVM describes the median distance where voxel intensities drop from 80% to 20% of target voxel values. The EVM was evaluated in a phantom study with a CIRS dynamic thorax phantom and with eleven on\u2010treatment lung SBRT patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      In the phantom study, the EVM was improved for 4D CBCT relative to 3D CBCT for one\u2010cm targets (2.43\u00a0\u00b1\u00a00.22\u00a0mm vs. 2.67\u00a0\u00b1\u00a00.31\u00a0mm,\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0=\u00a00.04) and for 2\u2010cm targets (2.60\u00a0\u00b1\u00a00.35\u00a0mm vs. 3.46\u00a0\u00b1\u00a01.03\u00a0mm,\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0=\u00a00.02). In patients, the EVM was 3.59\u00a0\u00b1\u00a01.01\u00a0mm vs. 4.25\u00a0\u00b1\u00a01.24\u00a0mm (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>When evaluating an imaging acquisition's degree of motion blurring and ability to delineate target edges, EVM may provide a less biased way to evaluate edge detection in the presence of motion when compared to traditional methods.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/acm2.70114","type":"journal-article","created":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T00:49:00Z","timestamp":1749170940000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["The edge visualization metric: Quantifying the improvement of lung SBRT target definition with 4D CBCT"],"prefix":"10.1002","volume":"26","author":[{"given":"Colton","family":"Baley","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology Mays Cancer Center at UT Health San Antonio  San Antonio Texas USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sam","family":"Andersen","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mays Cancer Center at UT Health San Antonio  San Antonio Texas USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Clark","family":"Anderson","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mays Cancer Center at UT Health San Antonio  San Antonio Texas USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shraddha","family":"Dalwadi","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mays Cancer Center at UT Health San Antonio  San Antonio Texas USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9372-992X","authenticated-orcid":false,"given":"Daniel L.","family":"Saenz","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mays Cancer Center at UT Health San Antonio  San Antonio Texas USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,6,5]]},"reference":[{"issue":"4","key":"e_1_2_10_2_1","first-page":"271","article-title":"Stereotactic body radiotherapy (SBRT) for T2N0 (>3\u00a0cm) non\u2010small cell lung cancer: outcomes and failure patterns","volume":"7","author":"Shamp SJ","year":"2021","journal-title":"J Radiosurg SBRT"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2017.12.020"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prro.2012.10.005"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.1869074"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/58\/5\/1447"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v17i6.6459"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1186\/1748\u2010717X\u20107\u201081"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13310"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1109\/IEMBS.2005.1615986"},{"issue":"1","key":"e_1_2_10_11_1","first-page":"1","article-title":"Study and comparison of various image edge detection techniques","volume":"3","author":"Maini R","year":"2009","journal-title":"Int J Image Process (IJIP)"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.7763\/IJET.2016.V8.876"},{"key":"e_1_2_10_13_1","doi-asserted-by":"crossref","unstructured":"DengG CahillLW.An adaptive Gaussian filter for noise reduction and edge detection. In:1993 IEEE conference record nuclear science symposium and medical imaging conference.IEEE;1993:1615\u20101619.","DOI":"10.1109\/NSSMIC.1993.373563"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/53\/23\/006"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2024.104876"},{"key":"e_1_2_10_16_1","doi-asserted-by":"crossref","unstructured":"GeorgeG OommenRM ShellyS PhiliposeSS VargheseAM.A survey on various median filtering techniques for removal of impulse noise from digital image. In:2018 Conference on Emerging Devices and Smart Systems (ICEDSS).IEEE;2018:235\u2010238. doi:10.1109\/ICEDSS.2018.8544273","DOI":"10.1109\/ICEDSS.2018.8544273"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1186\/1748\u2010717X\u20107\u201081"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2016.08.008"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.70114","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/acm2.70114","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.70114","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T17:59:43Z","timestamp":1772992783000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.70114"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,5]]},"references-count":17,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["10.1002\/acm2.70114"],"URL":"https:\/\/doi.org\/10.1002\/acm2.70114","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,5]]},"assertion":[{"value":"2024-10-08","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-04-10","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-06-05","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70114"}}