{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T04:37:24Z","timestamp":1783399044615,"version":"3.54.6"},"reference-count":30,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2025,5,29]],"date-time":"2025-05-29T00:00:00Z","timestamp":1748476800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,5,29]],"date-time":"2025-05-29T00:00:00Z","timestamp":1748476800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Stereotactic radiotherapy (SRT) is a highly effective treatment with precision for small, localized lesions. Proton therapy, characterized by the Bragg peak, offers superior dose conformity compared to photon\u2010based approaches. However, challenges remain in minimizing lateral penumbra and optimizing dose delivery, particularly for small targets. This study presents the first clinical application of collimated apertures integrated with the proton line scanning technique for proton stereotactic radiotherapy (PSRT). The aim was to evaluate the dosimetric advantages and clinical feasibility of this innovative approach.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Over a 1\u2010year period, 30 patients with small lesions, including choroid melanoma and arteriovenous malformations, were treated using proton line scanning. Two planning strategies were evaluated: uncollimated proton line scanning (UPLS) and collimated proton line scanning (CPLS), incorporating patient\u2010specific apertures. Dosimetric comparisons were conducted using the Homogeneity Index (HI), Paddick Conformity Index (CI\n                      <jats:sub>Paddick<\/jats:sub>\n                      ), Gradient Index (GI), and R50%. Treatment accuracy was validated using absolute dose measurements and Gamma Passing Rate (GPR) analysis under the criteria of 3%\/3 and 2%\/2\u00a0mm.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Plans incorporating customized collimated apertures showed significant improvements in dose conformity, with higher CI\n                      <jats:sub>Paddick<\/jats:sub>\n                      values (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.001), and exhibited steeper dose fall\u2010off, as reflected in lower GI and R50% values (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.001). A trend toward more homogeneous dose distributions was also observed (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.001). GPR analysis confirmed high treatment accuracy, with an average value of 99.00\u00a0\u00b1\u00a01.83% (3%\/3\u00a0mm) and 91.06\u00a0\u00b1\u00a04.91% (2%\/2\u00a0mm).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Integrating customized collimated apertures with proton beam line scanning is clinically feasible, improving precision, dose conformity, and healthy tissue sparing in PSRT. These findings support adopting this novel approach to advance precision proton therapy for small lesions.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/acm2.70128","type":"journal-article","created":{"date-parts":[[2025,5,29]],"date-time":"2025-05-29T10:54:31Z","timestamp":1748516071000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Dosimetric evaluation and clinical application of collimated apertures with proton beam line scanning in stereotactic radiotherapy"],"prefix":"10.1002","volume":"26","author":[{"given":"Chen\u2010Yu","family":"Chou","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology Linkou Chang Gung Memorial Hospital  Taoyuan City Taiwan (R.O.C)"},{"name":"Department of Biomedical Imaging and Radiological Sciences National Yang Ming Chiao Tung University  Taipei City Taiwan (R.O.C)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hsiao\u2010Chieh","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Linkou Chang Gung Memorial Hospital  Taoyuan City Taiwan (R.O.C)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shen\u2010Hao","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Linkou Chang Gung Memorial Hospital  Taoyuan City Taiwan (R.O.C)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shih\u2010Ming","family":"Hsu","sequence":"additional","affiliation":[{"name":"Department of Biomedical Imaging and Radiological Sciences National Yang Ming Chiao Tung University  Taipei City Taiwan (R.O.C)"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,5,29]]},"reference":[{"issue":"1","key":"e_1_2_9_2_1","first-page":"20","article-title":"Dosimetric comparison of proton versus photon stereotactic radiosurgery for treatment of vestibular schwannoma","author":"Sud S","year":"2023","journal-title":"Appl Rad Oncol"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.adro.2021.100806"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1042-3680(18)30191-8"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1080\/028418699431573"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.3171\/jns.2003.99.2.0254"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/s0360\u20103016(97)00721\u20109"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1080\/02841860310017676"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/s0360\u20103016(97)00720\u20107"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361\u20106560\/aab79c"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/61\/1\/12"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20190598"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2020.02.019"},{"key":"e_1_2_9_14_1","first-page":"121","article-title":"Pituitary irradiation with high\u2010energy proton beams: a preliminary report","volume":"18","author":"Lawrence JH","year":"1958","journal-title":"Cancer Res"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361\u20106560\/aacd27"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.3390\/cancers15164084"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.3390\/cancers16020403"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.14338\/IJPT\u201016\u201000017.1"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3158731"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14362"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/0360\u20103016(93)90548\u2010a"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00066\u2010018\u20101416\u2010x"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.3171\/jns.2000.93.supplement"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.3171\/sup.2006.105.7.194"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2018.11.051"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12043"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/56\/24\/009"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/57\/4\/983"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12783"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4942386"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.14021"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.70128","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/acm2.70128","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.70128","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T18:00:37Z","timestamp":1772992837000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.70128"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,29]]},"references-count":30,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["10.1002\/acm2.70128"],"URL":"https:\/\/doi.org\/10.1002\/acm2.70128","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,29]]},"assertion":[{"value":"2025-01-15","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-04-23","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-29","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70128"}}