{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T14:08:00Z","timestamp":1771337280203,"version":"3.50.1"},"reference-count":11,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T00:00:00Z","timestamp":1768348800000},"content-version":"vor","delay-in-days":13,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>PURPOSE<\/jats:title>\n                    <jats:p>\n                      The exposure index (EI), the target exposure index (EI\n                      <jats:sub>T<\/jats:sub>\n                      ), and the deviation index (DI) have been defined in the IEC Standard 62494\u20101 Ed.1 2008\u201008. This study investigates the impact of certain acquisition parameters, the imaged anatomy, and the manufacturer's specificities on the EI of radiological images and how these may affect EI\n                      <jats:sub>T<\/jats:sub>\n                      setting procedure.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>Images were acquired using two digital radiography (DR) systems of two different manufacturers, using aluminum attenuators and an anthropomorphic phantom. Acquisition parameters like the tube potential (kVp), the tube loading (mAs), the exposure time, the automatic exposure control (AEC) system settings (sensor and dose level selection), the grid (with or without), the additional filtration, the field size, and the imaged anatomy were varied and their effect on the EI was quantified separately for each system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>EI is linearly related to the incident air kerma (IAK) on the detector as expected (by definition). For constant IAK, EI increases with increasing kVp. While EI in general is reduced in the presence of scatter, this may not always be the case. Under AEC operation, even the exposure time can make a difference. EI is strongly affected by the imaged anatomy in combination with the AEC sensor and field size selections, the examination protocol, and the manufacturer.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>\n                      Many parameters affect the EI calculation apart from IAK. Among them, the most important are the imaged anatomy and the manufacturer. Since the EI calculation is a complex procedure, setting of the EI\n                      <jats:sub>T<\/jats:sub>\n                      values should be done with caution on a per\u2010examination and manufacturer basis, since the values that apply for one digital system are not always applicable to another. Furthermore, when EI is used as an image quality tool, a DI variation of at least \u00b12 should be allowed before a possibly meaningful red flag is activated.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/acm2.70331","type":"journal-article","created":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T16:02:31Z","timestamp":1768406551000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Exposure index in digital radiography and its dependence on acquisition parameters, anatomy, and manufacturer"],"prefix":"10.1002","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8007-1682","authenticated-orcid":false,"given":"Ioannis A.","family":"Tsalafoutas","sequence":"first","affiliation":[{"name":"Medical Physics Section OHS Department Hamad Medical Corporation  Doha Qatar"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3750-3683","authenticated-orcid":false,"given":"Shady","family":"AlKhazzam","sequence":"additional","affiliation":[{"name":"Medical Physics Section OHS Department Hamad Medical Corporation  Doha Qatar"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammed Hassan","family":"Kharita","sequence":"additional","affiliation":[{"name":"Medical Physics Section OHS Department Hamad Medical Corporation  Doha Qatar"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2026,1,14]]},"reference":[{"key":"e_1_2_9_2_1","first-page":"472","article-title":"The potential for unnecessary patient exposure from the use of storage phosphor imaging systems","volume":"1987","author":"Freedman M","year":"1993","journal-title":"SPIE Med Imaging SPIE Proc"},{"key":"e_1_2_9_3_1","unstructured":"GurD FuhmanCR FeistJH.Natural migration to a higher dose in CR imaging.Proceedings of the Eight European Congress of Radiology;1993:154."},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00247\u2010004\u20101269\u20106"},{"key":"e_1_2_9_5_1","unstructured":"AAPM.Acceptance Testing and Quality Control of Photostimulable Storage Phosphor Imaging Systems Report of AAPM Task Group 10; 2006."},{"key":"e_1_2_9_6_1","unstructured":"International Electrotechnical Commission.IEC Standard 62494\u20101 Ed. 1 2008\u201008; 2008."},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3121505"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.13212"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.12.8678"},{"issue":"1","key":"e_1_2_9_10_1","first-page":"83","article-title":"Best practices in digital radiography","volume":"84","author":"Herrmann TL","year":"2012","journal-title":"Radiol Technol"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radi.2020.02.009"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejro.2022.100454"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.70331","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/acm2.70331","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.70331","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T13:08:53Z","timestamp":1771333733000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.70331"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":11,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1]]}},"alternative-id":["10.1002\/acm2.70331"],"URL":"https:\/\/doi.org\/10.1002\/acm2.70331","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1]]},"assertion":[{"value":"2025-05-15","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-08","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-01-14","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70331"}}