{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T11:16:53Z","timestamp":1767179813956,"version":"3.48.0"},"reference-count":33,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2025,12,12]],"date-time":"2025-12-12T00:00:00Z","timestamp":1765497600000},"content-version":"vor","delay-in-days":11,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Cone beam CT (CBCT) has been reported for intensity\u2010modulated radiation therapy (IMRT) of various cancers due to its real\u2010time imaging capabilities, but studies on its application in orbital diseases, particularly moderate to severe thyroid\u2010associated ophthalmopathy (TAO), remain limited.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To investigate the clinical applications of CBCT in IMRT for TAO, with a focus on setup accuracy, dosimetric impact, and short\u2010term changes in eye prominence.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A total of 115 CBCT scans from 17 TAO patients were analyzed. Pretreatment CBCT scans were registered to the planning CT using bony anatomy. The resulting setup errors were quantified in three translational directions. Residual shifts after online correction were tracked to assess interfractional variation and trends throughout the treatment course. Dose\u2010volume histogram from plans recalculated with simulated setup errors (mean and maximum values) were compared to the original plan. Eye prominence was measured on serial CBCT scans, and its correlation with cumulative dose was analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Mean setup errors were (\u20130.16\u00a0\u00b1\u00a01.09) mm, (\u20130.19\u00a0\u00b1\u00a01.18) mm, and (\u20130.55\u00a0\u00b1\u00a01.05) mm in X, Y, and Z directions. Errors significantly decreased planning target volume (PTV) conformity (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.05) and increased\n                      <jats:italic>D<\/jats:italic>\n                      <jats:sub>mean<\/jats:sub>\n                      ,\n                      <jats:italic>D<\/jats:italic>\n                      <jats:sub>max<\/jats:sub>\n                      ,\n                      <jats:italic>D<\/jats:italic>\n                      <jats:sub>2%,<\/jats:sub>\n                      and\n                      <jats:italic>D<\/jats:italic>\n                      <jats:sub>50%<\/jats:sub>\n                      (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.05). For organs at risk (OARs), maximum and mean doses increased, with left lens\n                      <jats:italic>D<\/jats:italic>\n                      <jats:sub>max<\/jats:sub>\n                      increasing by 21.3%, 32.7%, 33.8%, and 13.2% for mean setup errors and X, Y, and Z maximum errors. Right lens showed similar increases. A correlation between CBCT\u2010measured eye prominence and total radiotherapy dose was observed, with the binomial fit: y\u00a0=\u00a022.43\n                      <jats:bold>+<\/jats:bold>\n                      0.12x \u2212 (9.94 \u00d7 10\n                      <jats:sup>\u22123<\/jats:sup>\n                      ) x\n                      <jats:sup>2<\/jats:sup>\n                      (\n                      <jats:italic>\n                        R\n                        <jats:sup>2<\/jats:sup>\n                      <\/jats:italic>\n                      \u00a0=\u00a00.96). Mean eye prominence decreased significantly from (21.74\u00a0\u00b1\u00a01.74) mm pre\u2010treatment to (20.94\u00a0\u00b1\u00a01.73) mm after 18\u00a0Gy of IMRT (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>CBCT image guidance for IMRT in moderate to severe TAO improves target conformity and coverage while reducing OAR doses, particularly for lenses. CBCT also shows promise for short\u2010term efficacy assessment of eye prominence in radiotherapy patients which may alleviate patient anxiety with preliminary observation thereby improving patient compliance with radiotherapy.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/acm2.70416","type":"journal-article","created":{"date-parts":[[2025,12,12]],"date-time":"2025-12-12T09:05:21Z","timestamp":1765530321000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Clinical application of cone beam CT in intensity\u2010modulated radiotherapy for the moderate to severe thyroid\u2010associated ophthalmopathy"],"prefix":"10.1002","volume":"26","author":[{"given":"Dan","family":"Kang","sequence":"first","affiliation":[{"name":"Department of Oncology The Third Xiangya Hospital, Central South University  Changsha Hunan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hao","family":"Hu","sequence":"additional","affiliation":[{"name":"Department of Oncology The Third Xiangya Hospital, Central South University  Changsha Hunan China"},{"name":"Radiotherapy Center The Third Xiangya Hospital, Central South University  Changsha Hunan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuyun","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Oncology The Third Xiangya Hospital, Central South University  Changsha Hunan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-0315-5305","authenticated-orcid":false,"given":"Shizhen","family":"Bin","sequence":"additional","affiliation":[{"name":"Department of Oncology The Third Xiangya Hospital, Central South University  Changsha Hunan China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,12,12]]},"reference":[{"key":"e_1_2_11_2_1","doi-asserted-by":"publisher","DOI":"10.1055\/s\u20100029\u20101212186"},{"key":"e_1_2_11_3_1","first-page":"207","volume-title":"Orbital Inflammatory Disease","author":"Lutt JR","year":"2008"},{"key":"e_1_2_11_4_1","doi-asserted-by":"publisher","DOI":"10.2147\/TCRM.S193018"},{"issue":"8","key":"e_1_2_11_5_1","first-page":"3471","article-title":"Clinical study of the radiotherapy with EDGE accelerator in the treatment of the moderate and severe thyroid associated ophthalmopathy","volume":"23","author":"Zeng L","year":"2019","journal-title":"Eur Rev Med Pharmacol Sci"},{"key":"e_1_2_11_6_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr.20140225"},{"key":"e_1_2_11_7_1","doi-asserted-by":"publisher","DOI":"10.3390\/cancers14194630"},{"key":"e_1_2_11_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2009.03.059"},{"key":"e_1_2_11_9_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361\u20106560\/aad1bb"},{"key":"e_1_2_11_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00270\u2010015\u20101180\u20106"},{"key":"e_1_2_11_11_1","doi-asserted-by":"publisher","DOI":"10.1186\/1748\u2010717X\u20108\u2010279"},{"key":"e_1_2_11_12_1","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics13101787"},{"key":"e_1_2_11_13_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365\u20102265.1997.2331047.x"},{"key":"e_1_2_11_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s40123\u2010019\u201000226\u20109"},{"key":"e_1_2_11_15_1","doi-asserted-by":"publisher","DOI":"10.1186\/1748\u2010717X\u20106\u201046"},{"volume-title":"ICRU News","year":"1999","author":"Wambersie A","key":"e_1_2_11_16_1"},{"key":"e_1_2_11_17_1","doi-asserted-by":"publisher","DOI":"10.1093\/jicru_ndq002"},{"key":"e_1_2_11_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2008.11.035"},{"key":"e_1_2_11_19_1","first-page":"361","article-title":"Accuracy and uncertainty considerations in modern radiation oncology","volume":"3","author":"Van Dyk J","year":"2013","journal-title":"Modern Technol Radiat Oncol"},{"key":"e_1_2_11_20_1","doi-asserted-by":"publisher","DOI":"10.3857\/roj.2017.00493"},{"key":"e_1_2_11_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2011.08.001"},{"key":"e_1_2_11_22_1","doi-asserted-by":"publisher","DOI":"10.3892\/ol.2020.11650"},{"key":"e_1_2_11_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2010.07.1980"},{"key":"e_1_2_11_24_1","unstructured":"TangiralaDK.Accurate location of tumor in head and neck cancer radiotherapy treatment with respect to machine isocentre.2017."},{"key":"e_1_2_11_25_1","doi-asserted-by":"publisher","DOI":"10.1177\/1533033820974021"},{"issue":"1","key":"e_1_2_11_26_1","first-page":"95","article-title":"Effects of error on dose of target region and organs at risk in treating nasopharynx cancer with intensity modulated radiation therapy","volume":"32","author":"Liu G","year":"2016","journal-title":"Pakistan J Med Sci"},{"key":"e_1_2_11_27_1","doi-asserted-by":"publisher","DOI":"10.4103\/0971\u20106203.181640"},{"key":"e_1_2_11_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2009.09.040"},{"key":"e_1_2_11_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2018.05.001"},{"key":"e_1_2_11_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tipsro.2020.02.002"},{"key":"e_1_2_11_31_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598\u2010017\u201017893\u2010y"},{"key":"e_1_2_11_32_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600\u20100420.2006.00822.x"},{"key":"e_1_2_11_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/0167\u20108140(96)01764\u20101"},{"key":"e_1_2_11_34_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.60.4.236"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.70416","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T11:13:38Z","timestamp":1767179618000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.70416"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":33,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2025,12]]}},"alternative-id":["10.1002\/acm2.70416"],"URL":"https:\/\/doi.org\/10.1002\/acm2.70416","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"type":"print","value":"1526-9914"},{"type":"electronic","value":"1526-9914"}],"subject":[],"published":{"date-parts":[[2025,12]]},"assertion":[{"value":"2025-05-11","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-25","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-12-12","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70416"}}