{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T16:41:17Z","timestamp":1792514477317,"version":"4.5.0"},"reference-count":46,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T00:00:00Z","timestamp":1792454400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T00:00:00Z","timestamp":1792454400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2026,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Filament deposition modeling (FDM) can be a practical method for producing quality control (QC) imaging resources for the clinic. However, frequent printing may degrade print quality over time.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To develop a process to ensure prints for the diagnostic physicist are accurate and reproducible.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Four FDM systems were evaluated by printing a custom, novel QC model on each printer 12 times over a period of 12 months. Several tests were performed, including print resolvability (lp\/cm), XYZ dimension accuracy (mm), density (g\/cm3), line width (mm), XY position accuracy (mm), clearance fits (mm), and thickness uniformity (mm). Polylactic acid (PLA) samples were printed, measured, and imaged with a dual energy CT scanner. Linear regression models were then created to monitor changes in QC density measurements as a function of x\u2010ray and material property characteristics (i.e., Hounsfield units and electron density). Between monthly prints, heat uniformity across the build plate was also tested for each printer using a NIST\u2010certified infrared thermometer and 3D printed grids. All physical measurements were obtained using a calibrated digital caliper and milligram scale.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Mean percent error (MPE) for all tests was calculated from ground truth (CAD dimensions and filament density) and baseline values (first month of QC measurements). Among printers investigated, MPE was \u00b1 5% of ground truth for all tests except density and thickness uniformity. Baseline MPE was also observed within \u00b1 5% except for resolvability and clearance fit tests among printers. Subtle trend increases were presented for higher density QC prints based on DECT linear regression models. Reduced chi\u2010squared values indicate uniform and reproducible heat bed temperature measurements.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This work offers an innovative approach toward evaluating and monitoring FDM system performance. Future work should track performance over a longer time period and across a wider variety of printers.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/acm2.70856","type":"journal-article","created":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T15:57:45Z","timestamp":1792511865000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Filament deposition modeling quality assurance testing for the medical physicist"],"prefix":"10.1002","volume":"27","author":[{"given":"Benjamin T.","family":"Heggie","sequence":"first","affiliation":[{"name":"Department of Radiology University of Florida  Gainesville Florida USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manuel","family":"Arreola","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Florida  Gainesville Florida USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephanie M.","family":"Leon","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Florida  Gainesville Florida USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Izabella L.","family":"Barreto","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Florida  Gainesville Florida USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,10,20]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.15407"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2025.105058"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmrs.387"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.8.3.033505"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12392"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12448"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.13058"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.16587"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.3390\/polym16081116"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13999"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13495"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.15494"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.15364"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12574"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/aisy.202400523"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.addma.2020.101749"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.3390\/pr13061772"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1186\/s41205\u2010022\u201000145\u20109"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmjstel\u20102017\u2010000234"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/advs.202101394"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1021\/acs.analchem.0c03299"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12206\u2010024\u20102407\u20108"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1177\/20552076231221899"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1148\/rg.2021200175"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.3390\/app14020509"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.addma.2024.104297"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.3390\/app15042046"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radi.2022.02.008"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2017.05.051"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cirpj.2024.09.005"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1148\/rg.2017160165"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.3390\/pr11102810"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.3390\/app14020945"},{"key":"e_1_2_10_35_1","volume-title":"Characterization and Optimization of a Single\u2010Source Sequential Dual Energy Computed Tomography System","author":"Olguin CA","year":"2021"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1186\/s41747\u2010018\u20100051\u20108"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.37206\/186"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.14.13126"},{"key":"e_1_2_10_39_1","doi-asserted-by":"publisher","DOI":"10.1007\/s40964\u2010022\u201000300\u2010y"},{"key":"e_1_2_10_40_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma14041021"},{"key":"e_1_2_10_41_1","doi-asserted-by":"publisher","DOI":"10.1186\/s41205\u2010017\u20100014\u20103"},{"key":"e_1_2_10_42_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.14850"},{"key":"e_1_2_10_43_1","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.10.2.026501"},{"key":"e_1_2_10_44_1","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20170524"},{"key":"e_1_2_10_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111690"},{"key":"e_1_2_10_46_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3567509"},{"key":"e_1_2_10_47_1","doi-asserted-by":"publisher","DOI":"10.1515\/eng\u20102021\u20100063"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.70856","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/acm2.70856","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.70856","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T15:57:46Z","timestamp":1792511866000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.70856"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,20]]},"references-count":46,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["10.1002\/acm2.70856"],"URL":"https:\/\/doi.org\/10.1002\/acm2.70856","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,20]]},"assertion":[{"value":"2026-04-03","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-24","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-10-20","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70856"}}