{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T05:48:47Z","timestamp":1792043327933,"version":"4.4.0"},"reference-count":20,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T00:00:00Z","timestamp":1791936000000},"content-version":"vor","delay-in-days":13,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["24K10828"],"award-info":[{"award-number":["24K10828"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Accurate assessment of fetal radiation dose during diagnostic X\u2010ray examinations remains challenging because commercially available pregnancy phantoms do not adequately reproduce fetal anatomy or permit organ\u2010specific dose measurements.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The purpose of this study was to develop a pregnant phantom with adjustable fetal presentation and to evaluate its anatomical realism and applicability for fetal dose assessment during pelvic radiography.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The developed phantom comprised an anthropomorphic phantom, a whole\u2010body fetal phantom, acrylic components, and water\u2010filled plastic bags. The fetal phantom was fabricated using three\u2010dimensional printing technology and incorporated bone\u2010equivalent and soft\u2010tissue\u2010equivalent materials. Fetal presentations could be adjusted to cephalic or breech presentations by repositioning the fetal phantom within the abdominal phantom. Computed tomography (CT) images were acquired to measure CT numbers of the fetal brain, thorax, abdomen, pelvic bone, and surrounding water\u2010filled regions. Absorbed doses were measured using real\u2010time dosimeters placed at five locations in the fetal head and three locations in the fetal abdomen. Dose measurements were performed during pelvic radiography and compared with those obtained using a conventional homogeneous pregnancy phantom.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The mean CT numbers of the fetal brain, thorax, abdomen, pelvic bone, and water\u2010filled regions were 2.1, \u20100.8, \u20100.4, 323.8, and 1.6 HU, respectively. These values were within the expected ranges for soft tissue and bone and were comparable to those of a conventional homogeneous phantom. During pelvic radiography, the mean absorbed doses measured using the adjustable fetal\u2010presentation phantom were 1.34 mGy in the fetal head and 0.07 mGy in the fetal abdomen for the cephalic presentation, and 0.05 mGy and 1.67 mGy, respectively, for the breech presentation. In comparison, the mean absorbed dose measured in the fetal region of the conventional homogeneous phantom was 2.05 mGy. The findings demonstrated substantial differences in regional fetal dose distribution according to fetal presentation. In particular, the fetal head dose in the cephalic presentation was lower than that measured using the conventional phantom. This difference may be partly attributable to attenuation by the fetal skull; however, the comparison should be interpreted with caution given differences in phantom geometry, internal materials, and dosimeter locations between the two phantoms.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>A novel pregnant phantom with adjustable fetal presentation was successfully developed. The phantom reproduced anatomically relevant structures using realistic bone\u2010equivalent and soft\u2010tissue\u2010equivalent materials and enabled direct dose measurements in specific fetal anatomical regions. Compared with a conventional homogeneous phantom, the developed phantom provided a more detailed assessment of fetal dose distributions and allowed evaluation of the effects of fetal presentation on radiation exposure during pelvic radiography.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/acm2.70859","type":"journal-article","created":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T05:29:42Z","timestamp":1792042182000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Development and validation of a pregnant phantom with adjustable fetal presentation for region\u2010specific fetal radiation dose assessment during pelvic radiography"],"prefix":"10.1002","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2356-9385","authenticated-orcid":false,"given":"Yuta","family":"Matsunaga","sequence":"first","affiliation":[{"name":"School of Medical Sciences Fujita Health University  Toyoake Aichi Japan"},{"name":"Department of Radiological Technology, Faculty of Health Sciences Tohoku University Graduate School of Medicine  Sendai Miyagi Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5503-6970","authenticated-orcid":false,"given":"Yumi","family":"Kataoka","sequence":"additional","affiliation":[{"name":"School of Medical Sciences Fujita Health University  Toyoake Aichi Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0913-2777","authenticated-orcid":false,"given":"Koichi","family":"Chida","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Sciences Tohoku University Graduate School of Medicine  Sendai Miyagi Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9559-4811","authenticated-orcid":false,"given":"Yasuki","family":"Asada","sequence":"additional","affiliation":[{"name":"School of Medical Sciences Fujita Health University  Toyoake Aichi Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,10,14]]},"reference":[{"issue":"3","key":"e_1_2_12_2_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3390\/tomography12030035","article-title":"Evaluation of radiation dose and image quality in the transition from conventional pelvimetry to low\u2010dose helical CT pelvimetry","volume":"12","author":"Shahgeldi K.","year":"2026","journal-title":"Tomography"},{"issue":"9840","key":"e_1_2_12_3_1","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/S0140-6736(12)60815-0","article-title":"Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study","volume":"380","author":"Pearce M. S","year":"2012","journal-title":"Lancet"},{"issue":"16","key":"e_1_2_12_4_1","doi-asserted-by":"crossref","first-page":"2052","DOI":"10.1097\/00007632-200008150-00009","article-title":"Breast cancer mortality after diagnostic radiography: findings from the U.S. scoliosis cohort study","volume":"25","author":"Morin Doody M.","year":"2000","journal-title":"Spine (Phila Pa 1976)"},{"issue":"10","key":"e_1_2_12_5_1","doi-asserted-by":"crossref","first-page":"20","DOI":"10.3390\/diagnostics10100753","article-title":"Reducing the breast cancer risk and radiation dose of radiography for scoliosis in children: a phantom study","volume":"10","author":"Nemoto M.","year":"2020","journal-title":"Diagnostics"},{"key":"e_1_2_12_6_1","first-page":"1","volume-title":"The Recommendations of the international commission on radiological protection","author":"The International Commission on Radiological Protection","year":"2007"},{"issue":"1","key":"e_1_2_12_7_1","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1093\/rpd\/ncs312","article-title":"Fetal doses to pregnant patients from CT with tube current modulation calculated using Monte Carlo simulations and realistic phantoms","volume":"155","author":"Gu J.","year":"2013","journal-title":"Radiation Protection Dosimetry"},{"key":"e_1_2_12_8_1","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1259\/bjr.72.856.10474497","article-title":"Fetal position and size data for dose estimation","volume":"72","author":"Osei E. K","year":"1999","journal-title":"British Journal of Radiology"},{"issue":"9239","key":"e_1_2_12_9_1","doi-asserted-by":"crossref","first-page":"1375","DOI":"10.1016\/S0140-6736(00)02840-3","article-title":"Planned caesarean section versus planned vaginal birth for breech presentation at term: a randomised multicentre trial","volume":"356","author":"Hannah M. E","year":"2000","journal-title":"Lancet"},{"issue":"2","key":"e_1_2_12_10_1","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1002\/acm2.12041","article-title":"Energy dependence and angular dependence of an optically stimulated luminescence dosimeter in the mammography energy range","volume":"18","author":"Kawaguchi A.","year":"2017","journal-title":"Journal of Applied Clinical Medical Physics"},{"issue":"9","key":"e_1_2_12_11_1","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ab0bd5","article-title":"VirtualDose\u2010IR: a cloud\u2010based software for reporting organ doses in interventional radiology","volume":"64","author":"Huo W.","year":"2019","journal-title":"Physics in Medicine & Biology"},{"issue":"2","key":"e_1_2_12_12_1","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1002\/acm2.13171","article-title":"Fetal radiation dose of four tube voltages in abdominal CT examinations during pregnancy: a phantom study","volume":"22","author":"Matsunaga Y.","year":"2021","journal-title":"Journal of Applied Clinical Medical Physics"},{"issue":"12","key":"e_1_2_12_13_1","doi-asserted-by":"crossref","first-page":"9264","DOI":"10.1002\/mp.17420","article-title":"3D printing of realistic body phantoms: comparison of measured and simulated organ doses on the example of a CT scan on a pregnant woman","volume":"51","author":"Kunert P.","year":"2024","journal-title":"Medical Physics"},{"issue":"2","key":"e_1_2_12_14_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/acm2.14240","article-title":"Development and validation of the low\u2010cost pregnant female physical phantom for fetal dosimetry in MV photon radiotherapy","volume":"25","author":"Kopa\u010din V.","year":"2024","journal-title":"Journal of Applied Clinical Medical Physics"},{"issue":"30560","key":"e_1_2_12_15_1","first-page":"1","article-title":"New reference values for ultrasound fetal biometry in Japanese population and comparison with other studies","volume":"15","author":"Nagasaki S.","year":"2025","journal-title":"Scientific Reports"},{"issue":"3","key":"e_1_2_12_16_1","doi-asserted-by":"crossref","first-page":"N12","DOI":"10.1088\/1361-6498\/ac125c","article-title":"Novel pregnant model phantoms for measurement of foetal radiation dose in x\u2010ray examinations","volume":"41","author":"Matsunaga Y.","year":"2021","journal-title":"Journal of Radiological Protection"},{"issue":"9","key":"e_1_2_12_17_1","doi-asserted-by":"crossref","first-page":"2741","DOI":"10.3390\/s20092741","article-title":"Development of novel real\u2010time radiation systems using 4\u2010channel sensors","volume":"20","author":"Inaba Y.","year":"2020","journal-title":"Sensors (Switzerland)"},{"key":"e_1_2_12_18_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejmp.2025.105021","article-title":"Analysis of CT Hounsfield units for fetal imaging: basic data for creating dosimetry phantoms of pregnant women","volume":"135","author":"Matsunaga Y.","year":"2025","journal-title":"Physica Medica"},{"issue":"1","key":"e_1_2_12_19_1","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1148\/radiol.2491071665","article-title":"Radiation dose to the fetus for pregnant patients undergoing multidetector CT imaging: monte Carlo simulations estimating fetal dose for a range of gestational age and patient size","volume":"249","author":"Angel E.","year":"2008","journal-title":"Radiology"},{"issue":"2","key":"e_1_2_12_20_1","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1007\/s12194-016-0377-y","article-title":"Radiation doses for pregnant women in the late pregnancy undergoing fetal\u2010computed tomography: a comparison of dosimetry and Monte Carlo simulations","volume":"10","author":"Matsunaga Y.","year":"2017","journal-title":"Radiological Physics and Technology"},{"issue":"5","key":"e_1_2_12_21_1","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.2214\/AJR.10.4497","article-title":"Fetal radiation dose during gestation estimated on an anthropomorphic phantom for three generations of CT scanners","volume":"196","author":"Gilet A. G","year":"2011","journal-title":"American Journal of Roentgenology"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.70859","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/acm2.70859","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/acm2.70859","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T05:29:46Z","timestamp":1792042186000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/acm2.70859"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":20,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["10.1002\/acm2.70859"],"URL":"https:\/\/doi.org\/10.1002\/acm2.70859","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"2026-07-13","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-10-03","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-10-14","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70859"}}