{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T23:15:53Z","timestamp":1790810153314,"version":"4.1.0"},"reference-count":47,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T00:00:00Z","timestamp":1763683200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T00:00:00Z","timestamp":1763683200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["advanced.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Advanced Science"],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Conventional X\u2010ray computed tomography systems for microstructure inspection typically employ a geometrically magnified imaging setup, requiring a micro\u2010focus X\u2010ray source to mitigate image blurring caused by a finite focal spot size. However, due to its low output power, the micro\u2010focus X\u2010ray source results in prolonged image acquisition times. This study presents a novel optically\u2010coupled X\u2010ray computed laminography system for high\u2010speed inspection. In the proposed system, a scintillator is placed in contact with an object, effectively minimizing image blurring despite the use of an X\u2010ray source with a large focal spot. Consequently, a high\u2010power X\u2010ray tube can be employed without compromising spatial resolution, leading to a significant reduction in scan time. Modulation transfer function analysis confirms that a spatial resolution of 38\u00a0\u00b5m is achieved using a high\u2010power (400\u00a0W) X\u2010ray tube with a 400\u00a0\u00b5m focal spot. In addition, high\u2010quality 3D imaging of lithium\u2010ion batteries (LIBs) is demonstrated with a scan time as low as 2\u00a0s and a contrast\u2010to\u2010noise ratio exceeding 3. By overcoming the trade\u2010off between the spatial resolution and the scan time in X\u2010ray imaging, the proposed system enables high\u2010throughput in\u2010line inspection of mass\u2010produced LIBs.<\/jats:p>","DOI":"10.1002\/advs.202517158","type":"journal-article","created":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T10:11:52Z","timestamp":1763719912000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Optically\u2010Coupled X\u2010Ray Computed Laminography System for High\u2010Speed Inspection of Lithium\u2010Ion Batteries"],"prefix":"10.1002","volume":"13","author":[{"given":"Jaeyoung","family":"Im","sequence":"first","affiliation":[{"name":"Department of Nuclear and Quantum Engineering Korea Advanced Institute of Science and Technology (KAIST)  291 Daehak\u2010ro, Yuseong\u2010gu Daejeon 34141 Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Heo","sequence":"additional","affiliation":[{"name":"Department of Nuclear and Quantum Engineering Korea Advanced Institute of Science and Technology (KAIST)  291 Daehak\u2010ro, Yuseong\u2010gu Daejeon 34141 Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seunguk","family":"Cheon","sequence":"additional","affiliation":[{"name":"Department of Nuclear and Quantum Engineering Korea Advanced Institute of Science and Technology (KAIST)  291 Daehak\u2010ro, Yuseong\u2010gu Daejeon 34141 Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jichan","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Nuclear and Quantum Engineering Korea Advanced Institute of Science and Technology (KAIST)  291 Daehak\u2010ro, Yuseong\u2010gu Daejeon 34141 Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5441-3244","authenticated-orcid":false,"given":"Sung Oh","family":"Cho","sequence":"additional","affiliation":[{"name":"Department of Nuclear and Quantum Engineering Korea Advanced Institute of Science and Technology (KAIST)  291 Daehak\u2010ro, Yuseong\u2010gu Daejeon 34141 Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,11,21]]},"reference":[{"key":"e_1_2_8_1_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41560-023-01355-z"},{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.xcrp.2021.100554"},{"key":"e_1_2_8_3_1","first-page":"3","volume":"4","author":"Chen W.","year":"2025","journal-title":"Green Energy Intell. Transp."},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1039\/C7EE00385D"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpowsour.2023.233265"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.3390\/batteries10020062"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.3390\/en17164030"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpowsour.2023.232742"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/ente.201600131"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-025-55861-7"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpowsour.2023.233542"},{"key":"e_1_2_8_12_1","doi-asserted-by":"crossref","unstructured":"Z.Wang Z.Li Q.Liu International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications SPIE Beijing China2011 8193.","DOI":"10.1117\/12.901592"},{"key":"e_1_2_8_13_1","first-page":"6","volume":"39","author":"Sun B.","year":"2024","journal-title":"Nondestruct. Test. Eval."},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.est.2024.111433"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11664-024-11300-9"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1080\/10589759.2022.2070165"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.3390\/en11040925"},{"key":"e_1_2_8_18_1","first-page":"13","volume":"7","author":"Arabi H.","year":"2010","journal-title":"Iran. J. Radiol."},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/872\/1\/012002"},{"key":"e_1_2_8_20_1","first-page":"139","volume":"32","author":"Seibert J. A.","year":"2004","journal-title":"J. Nucl. Med. Technol."},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.15611"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.17528"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1088\/0957-0233\/23\/8\/085404"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.16859"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.3390\/s21248493"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.3390\/batteries9110555"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2016.2643601"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mattod.2025.02.023"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1107\/S1600577525007234"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.3390\/en12152865"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.precisioneng.2021.10.015"},{"key":"e_1_2_8_32_1","volume-title":"Principles of Computerized Tomographic Imaging","author":"Kak A. C.","year":"1988"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1107\/S1600577522007652"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.1364\/OE.16.003223"},{"key":"e_1_2_8_35_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.3115402"},{"key":"e_1_2_8_36_1","first-page":"12","volume":"30","author":"Levi D. M.","year":"1990","journal-title":"Vision Res."},{"key":"e_1_2_8_37_1","doi-asserted-by":"publisher","DOI":"10.1080\/14786447408640996"},{"key":"e_1_2_8_38_1","first-page":"8","volume":"12","author":"Swank R. K.","year":"1865","journal-title":"Appl. Opt."},{"key":"e_1_2_8_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijheatmasstransfer.2007.06.034"},{"key":"e_1_2_8_40_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2919724"},{"key":"e_1_2_8_41_1","doi-asserted-by":"publisher","DOI":"10.1364\/AO.57.000B83"},{"key":"e_1_2_8_42_1","doi-asserted-by":"publisher","DOI":"10.1109\/42.126908"},{"key":"e_1_2_8_43_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41565-025-01906-3"},{"key":"e_1_2_8_44_1","doi-asserted-by":"publisher","DOI":"10.1149\/1945-7111\/ad4a12"},{"key":"e_1_2_8_45_1","first-page":"2","volume":"20","author":"Xu F.","year":"2012","journal-title":"Opt. Express"},{"key":"e_1_2_8_46_1","doi-asserted-by":"publisher","DOI":"10.3390\/s23094324"},{"key":"e_1_2_8_47_1","unstructured":"ASTM. International Standard Practice for Radiological Examination Using Digital Detector Arrays2010."}],"container-title":["Advanced Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/advanced.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/advs.202517158","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/advanced.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/advs.202517158","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/advanced.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/advs.202517158","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T09:08:07Z","timestamp":1770109687000},"score":1,"resource":{"primary":{"URL":"https:\/\/advanced.onlinelibrary.wiley.com\/doi\/10.1002\/advs.202517158"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,21]]},"references-count":47,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["10.1002\/advs.202517158"],"URL":"https:\/\/doi.org\/10.1002\/advs.202517158","archive":["Portico"],"relation":{},"ISSN":["2198-3844","2198-3844"],"issn-type":[{"value":"2198-3844","type":"print"},{"value":"2198-3844","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,21]]},"assertion":[{"value":"2025-09-02","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-21","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e17158"}}