{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T21:22:08Z","timestamp":1783113728043,"version":"3.54.6"},"reference-count":28,"publisher":"Wiley","issue":"34","license":[{"start":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T00:00:00Z","timestamp":1776816000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T00:00:00Z","timestamp":1776816000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["advanced.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Advanced Science"],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>Looping during colonoscopy procedures is a major cause of patient discomfort and increases the risk of complications. With the rising incidence of colorectal cancer, there is an urgent need for safer and more efficient colonoscopy techniques. We developed a proof\u2010of\u2010concept platform for 3D visualization of the colonoscope combined with artificial intelligence (AI)\u2010based loop detection. The system consists of an array of 15 inertial measurement units (IMUs) mounted on a flexible printed circuit board that can be retrofitted into the instrument channel of conventional colonoscopes. Using sensor fusion algorithms, the position and orientation of individual IMUs are estimated to reconstruct the 3D shape of the colonoscope in real time. The system successfully reconstructed the colonoscope shape in a silicone colon phantom, and the AI model achieved high loop\u2010detection performance with an area under the receiver operating characteristic curve of 0.95 on test data. These results demonstrate feasibility in an artificial environment, while further validation in clinical settings is required.<\/jats:p>","DOI":"10.1002\/advs.75119","type":"journal-article","created":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T10:47:32Z","timestamp":1776854852000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Flexible IMU Sensor Array For 3D Colonoscope Shape Reconstruction and AI\u2010Based Loop Detection"],"prefix":"10.1002","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0706-7542","authenticated-orcid":false,"given":"Tuukka","family":"Panula","sequence":"first","affiliation":[{"name":"Department of computing University of Turku Turku Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anni","family":"Halkilahti","sequence":"additional","affiliation":[{"name":"Department of computing University of Turku Turku Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrei","family":"Ivanov","sequence":"additional","affiliation":[{"name":"Department of computing University of Turku Turku Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8118-2851","authenticated-orcid":false,"given":"Matti","family":"Kaisti","sequence":"additional","affiliation":[{"name":"Department of computing University of Turku Turku Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,4,22]]},"reference":[{"key":"e_1_2_9_2_1","unstructured":"World Health Organization \u201cColorectal Cancer \u201dWorld Health Organization(2023). Available:https:\/\/www.who.int\/news\u2010room\/fact\u2010sheets\/detail\/colorectal\u2010cancer."},{"issue":"1","key":"e_1_2_9_3_1","first-page":"51","article-title":"Colorectal Cancer Incidence Trends in Younger Versus Older Adults: An Analysis of Population\u2010Based Cancer Registry Data","volume":"117","author":"Sung H.","year":"2025","journal-title":"Journal of the National Cancer Institute"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.3748\/wjg.v23.i20.3632"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.mcg.0000225595.01201.d2"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/353760"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1440-1746.2008.05739.x"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/den.13465"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.2174\/1875181401305010001"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2025.3540099"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.4161\/jig.23738"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/SLE.0000000000001236"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIM.2020.3015607"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIM.2023.3244219"},{"issue":"9","key":"e_1_2_9_15_1","first-page":"1150","article-title":"Enhancing Human\u2010AI Collaboration: The Case of Colonoscopy","volume":"55","author":"Introzzi L.","year":"2023","journal-title":"Digestive and Liver Disease"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1038\/s42256-020-00231-9"},{"key":"e_1_2_9_17_1","doi-asserted-by":"crossref","unstructured":"M.Oda H. R.Roth T.Kitasaka et\u00a0al. \u201cColonoscope Tracking Method Based on Shape Estimation Network \u201d inMedical Imaging 2019: Image\u2010Guided Procedures Robotic Interventions and Modeling10951(SPIE 2019) 183\u2013188.","DOI":"10.1117\/12.2512729"},{"key":"e_1_2_9_18_1","doi-asserted-by":"crossref","unstructured":"M.Oda H. R.Roth T.Kitasaka et\u00a0al. \u201cColon Shape Estimation Method for Colonoscope Tracking Using Recurrent Neural Networks \u201d inInternational Conference on Medical Image Computing and Computer\u2010Assisted Intervention(Springer 2018) 176\u2013184.","DOI":"10.1007\/978-3-030-00937-3_21"},{"key":"e_1_2_9_19_1","doi-asserted-by":"crossref","unstructured":"Z.HuangandC.Hu \u201cReal\u2010Time Attitude Tracking of Capsule Endoscope Based on MEMS IMU and Error Analysis \u201d in2021 IEEE International Conference on Real\u2010Time Computing and Robotics (RCAR)(IEEE 2021) 968\u2013973.","DOI":"10.1109\/RCAR52367.2021.9517523"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIM.2022.3204103"},{"key":"e_1_2_9_21_1","doi-asserted-by":"crossref","unstructured":"J.Lee H.Ishii andA.Takanishi \u201cShape Visualization Method of Flexible Colonoscopy Using Non\u2010Visual Sensor Network for Monitoring of Operation \u201d in2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society(IEEE 2011) 524\u2013527.","DOI":"10.1109\/IEMBS.2011.6090095"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMRB.2025.3573053"},{"key":"e_1_2_9_23_1","doi-asserted-by":"crossref","unstructured":"R. E.Schapire \u201cExplaining AdaBoost \u201d inEmpirical Inference: Festschrift in Honor of Vladimir N. Vapnik(Springer 2013) 37\u201352.","DOI":"10.1007\/978-3-642-41136-6_5"},{"key":"e_1_2_9_24_1","unstructured":"O. J.Woodman \u201cAn Introduction to Inertial Navigation \u201dTechnical Report UCAM\u2010CL\u2010TR\u2010696(University of Cambridge Computer Laboratory 2007)."},{"key":"e_1_2_9_25_1","doi-asserted-by":"crossref","unstructured":"M.Oda H.Kondo T.Kitasaka et\u00a0al. \u201cTracking Accuracy Evaluation of Electromagnetic Sensor\u2010Based Colonoscope Tracking Method \u201d inInternational Workshop on Computer\u2010Assisted and Robotic Endoscopy(Springer 2015) 101\u2013108.","DOI":"10.1007\/978-3-319-29965-5_10"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compmedimag.2013.01.010"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-024-01412-1"},{"key":"e_1_2_9_28_1","doi-asserted-by":"crossref","unstructured":"P.Jackson R.Simon andC.Linte \u201cSurgical Tracking Registration and Navigation Characterization for Image\u2010Guided Renal Interventions \u201d in2020 42nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)(IEEE 2020) 5081\u20135084.","DOI":"10.1109\/EMBC44109.2020.9175270"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-021-01804-7"}],"container-title":["Advanced Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/advanced.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/advs.75119","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/advanced.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/advs.75119","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/advanced.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/advs.75119","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T20:55:14Z","timestamp":1783112114000},"score":1,"resource":{"primary":{"URL":"https:\/\/advanced.onlinelibrary.wiley.com\/doi\/10.1002\/advs.75119"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,22]]},"references-count":28,"journal-issue":{"issue":"34","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["10.1002\/advs.75119"],"URL":"https:\/\/doi.org\/10.1002\/advs.75119","archive":["Portico"],"relation":{},"ISSN":["2198-3844","2198-3844"],"issn-type":[{"value":"2198-3844","type":"print"},{"value":"2198-3844","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,22]]},"assertion":[{"value":"2026-01-24","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-19","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-22","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e75119"}}