{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,17]],"date-time":"2026-01-17T23:53:09Z","timestamp":1768693989526,"version":"3.49.0"},"reference-count":16,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2003,4,14]],"date-time":"2003-04-14T00:00:00Z","timestamp":1050278400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["American J Industrial Med"],"published-print":{"date-parts":[[2003,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Injuries due to high\u2010pressure injections are frequently underestimated occupational accidents, which may have disabling outcomes.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The occupational injuries logbooks of two shipyards were examined. Twelve accidents due to the utilization of high\u2010pressure equipment were reported. Data were obtained by reviewing the employers' logbooks and hospital records.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Contaminants were epoxy paint and stucco, paint solvent, hydraulic and industrial oil. In three cases, the palm was injured and the fingers in nine. In 91% of cases, the accident occurred in the last 2 hr of the work shift. Mishandling (n\u2009=\u20099) and rupture of the high\u2010pressure equipment (n\u2009=\u20093) were the causes. Mean time to medical treatment was 42.5 hr (SD 56.0). Ten workers were permanently disabled.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Prompt surgical intervention with debridement and decompression was done in two workers, who healed completely. The ten patients who were not treated immediately eventually experienced a high rate of disability and five of them also suffered amputation. Am. J. Ind. Med. 43:539\u2013542, 2003. \u00a9 2003 Wiley\u2010Liss, Inc.<\/jats:p><\/jats:sec>","DOI":"10.1002\/ajim.10218","type":"journal-article","created":{"date-parts":[[2003,4,15]],"date-time":"2003-04-15T12:46:30Z","timestamp":1050410790000},"page":"539-542","source":"Crossref","is-referenced-by-count":35,"title":["Hand injuries due to high\u2010pressure injection devices for painting in shipyards: Circumstances, management, and outcome in twelve patients"],"prefix":"10.1002","volume":"43","author":[{"given":"Matteo","family":"Valentino","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Venerando","family":"Rapisarda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Concettina","family":"Fenga","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2003,4,14]]},"reference":[{"key":"e_1_2_1_2_1","first-page":"2461","article-title":"High pressure injection accident of the hand","volume":"44","author":"Ebelin M","year":"1994","journal-title":"Rev Prat"},{"key":"e_1_2_1_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-199601000-00038"},{"key":"e_1_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1097\/00007611-198212000-00012"},{"key":"e_1_2_1_5_1","first-page":"13","article-title":"High\u2010pressure injection injuries of the hand","volume":"92","author":"Jebson PJ","year":"1993","journal-title":"Wis Med J"},{"key":"e_1_2_1_6_1","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1016\/S0733-8627(20)30937-8","article-title":"High\u2010compression injection injuries to the hand","volume":"3","author":"Lewis RC","year":"1985","journal-title":"Emerg Med Clin North Am"},{"key":"e_1_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0753-9053(05)80463-6"},{"key":"e_1_2_1_8_1","doi-asserted-by":"publisher","DOI":"10.3109\/15563658708992633"},{"key":"e_1_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-197501000-00004"},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-199101000-00021"},{"key":"e_1_2_1_11_1","first-page":"511","article-title":"High\u2010pressure injection injuries","volume":"34","author":"Peters W","year":"1991","journal-title":"CJS"},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(93)90256-3"},{"key":"e_1_2_1_13_1","doi-asserted-by":"crossref","unstructured":"RamosH PoschJL LieKK.1970.High\u2010pressure injection injuries of the hand. Plast Reconstr Surg45:221\u2013226.","DOI":"10.1097\/00006534-197003000-00003"},{"key":"e_1_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1937.92780370004012c"},{"key":"e_1_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-198003000-00007"},{"key":"e_1_2_1_16_1","first-page":"714","article-title":"High\u2010pressure injection injuries of the hand. A review","volume":"55","author":"Sirio CA","year":"1989","journal-title":"Am Surg"},{"key":"e_1_2_1_17_1","first-page":"332","article-title":"Delayed diagnosis of high\u2010pressure injection injuries to the finger. A case report and review of the literature","volume":"60","author":"Stoffelen D","year":"1994","journal-title":"Acta Orthop Belg"}],"container-title":["American Journal of Industrial Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fajim.10218","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ajim.10218","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,18]],"date-time":"2023-11-18T00:23:30Z","timestamp":1700267010000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ajim.10218"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,4,14]]},"references-count":16,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2003,5]]}},"alternative-id":["10.1002\/ajim.10218"],"URL":"https:\/\/doi.org\/10.1002\/ajim.10218","archive":["Portico"],"relation":{},"ISSN":["0271-3586","1097-0274"],"issn-type":[{"value":"0271-3586","type":"print"},{"value":"1097-0274","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,4,14]]}}}