{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,26]],"date-time":"2025-12-26T08:05:30Z","timestamp":1766736330190,"version":"3.48.0"},"reference-count":20,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2025,12,26]],"date-time":"2025-12-26T00:00:00Z","timestamp":1766707200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["aornjournal.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["AORN Journal"],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>\n                    <jats:boxed-text content-type=\"graphic\" position=\"anchor\">\n                      <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" mimetype=\"image\/png\" position=\"anchor\" specific-use=\"enlarged-web-image\" xlink:href=\"graphic\/aorn70004-toc-0001-m.png\">\n                        <jats:alt-text>image<\/jats:alt-text>\n                      <\/jats:graphic>\n                    <\/jats:boxed-text>\n                  <\/jats:p>\n                  <jats:p>Studies have shown that using warmed irrigation solution is an effective method for maintaining perioperative patient normothermia. This randomized single\u2010blind comparative study aimed to evaluate the accuracy of a hand\u2010checking method to assess irrigation fluid temperature and suitability for use. Twenty\u2010eight scrub nurses were enrolled and assigned to one of three groups using either hot, cold, or euthermic irrigation fluid. Measurements were taken at 30\u2010minute intervals in either a cold (18\u00a0\u00b0C [64.4\u00a0\u00b0F]) or room\u2010temperature (22\u00a0\u00b0C to 24\u00a0\u00b0C [71.6\u00a0\u00b0F to 75.2\u00a0\u00b0F]) environment. Incorrect assessments regarding irrigation fluid temperature were made by 89.3% of participants, with 78.6% doing so in the cold environment. Participants with experience in gynecological and plastic surgery were more accurate in their assessments. This study revealed disparities between subjective assessments and objectively measured temperatures. The high rate of inaccurate evaluations underscores the need to use objective methods for temperature measurements.<\/jats:p>","DOI":"10.1002\/aorn.70004","type":"journal-article","created":{"date-parts":[[2025,12,26]],"date-time":"2025-12-26T08:00:27Z","timestamp":1766736027000},"page":"89-100","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy of Subjective Temperature Assessment of Surgical Irrigation Fluids: A Randomized Controlled Single\u2010Blind Comparative Study"],"prefix":"10.1002","volume":"123","author":[{"given":"Nuran Ay\u015fen","family":"Pamir Aksoy","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nermin","family":"Ocaktan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,12,26]]},"reference":[{"key":"e_1_2_11_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bpa.2007.10.004"},{"key":"e_1_2_11_3_1","unstructured":"Australian College of Perianaesthesia Nurses.Prevention and management of inadvertent perioperative hypothermia in adults.Practice Guideline01. May2023. Accessed December 20 2024.http:\/\/www.acpan.edu.au\/public\/228\/files\/Guidelines%20\u2010%20ACPAN\/acpan\u2010guideline\u2010pg01\u2010perioperative\u2010hypothermia\u2010prevention\u2010and\u2010management\u2010in\u2010adults.pdf"},{"key":"e_1_2_11_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pcorm.2020.100150"},{"key":"e_1_2_11_5_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.jvca.2022.09.077"},{"key":"e_1_2_11_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/jocn.16080"},{"key":"e_1_2_11_7_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598\u2010023\u201030819\u20101"},{"key":"e_1_2_11_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jopan.2023.02.002"},{"key":"e_1_2_11_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijnurstu.2023.104508"},{"key":"e_1_2_11_10_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12871\u2010023\u201002084\u20102"},{"key":"e_1_2_11_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365\u20102702.2008.02668.x"},{"key":"e_1_2_11_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365\u20102702.2010.03484.x"},{"key":"e_1_2_11_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jopan.2019.06.006"},{"key":"e_1_2_11_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2017.09.024"},{"key":"e_1_2_11_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/aorn.13038"},{"key":"e_1_2_11_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajic.2014.01.012"},{"key":"e_1_2_11_17_1","doi-asserted-by":"publisher","DOI":"10.4103\/0259\u20101162.134508"},{"key":"e_1_2_11_18_1","doi-asserted-by":"publisher","DOI":"10.1177\/17504589221122651"},{"key":"e_1_2_11_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jopan.2020.03.011"},{"key":"e_1_2_11_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjps.2014.06.017"},{"issue":"1","key":"e_1_2_11_21_1","first-page":"13","article-title":"Thermal sensitivity and physiological response of hands wearing gloves with different thermal conductivities in water","volume":"59","author":"Isaji S","year":"2008","journal-title":"J Home Econ Jpn."}],"container-title":["AORN Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aornjournal.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/aorn.70004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,26]],"date-time":"2025-12-26T08:00:43Z","timestamp":1766736043000},"score":1,"resource":{"primary":{"URL":"https:\/\/aornjournal.onlinelibrary.wiley.com\/doi\/10.1002\/aorn.70004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,26]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1]]}},"alternative-id":["10.1002\/aorn.70004"],"URL":"https:\/\/doi.org\/10.1002\/aorn.70004","archive":["Portico"],"relation":{},"ISSN":["0001-2092","1878-0369"],"issn-type":[{"value":"0001-2092","type":"print"},{"value":"1878-0369","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,26]]},"assertion":[{"value":"2025-04-03","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-08-19","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-12-26","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}