{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T07:17:34Z","timestamp":1788333454815,"version":"build-2803163510"},"reference-count":19,"publisher":"Wiley","license":[{"start":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T00:00:00Z","timestamp":1788307200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T00:00:00Z","timestamp":1788307200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["arthroscopyjournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Superior capsular reconstruction is a surgical procedure used for treating massive irreparable rotator cuff tears by restoring joint biomechanics and stability using a graft construct. Evaluating postoperative success has often involved magnetic resonance imaging studies to assess the integrity and durability of the reconstructed grafts. However, an intact\u2010appearing superior capsular reconstruction graft on magnetic resonance imaging may not always represent a functionally competent construct, especially in the setting of progressive graft thinning and humeral head migration over time. As such, surgeons and researchers should interpret postoperative magnetic resonance imaging findings with caution. Superior capsular reconstruction success should not be defined solely by graft continuity, but rather by the combined assessment of joint biomechanics, graft morphology, and patient\u2010reported outcomes.<\/jats:p>","DOI":"10.1002\/arj.70500","type":"journal-article","created":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T07:02:58Z","timestamp":1788332578000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["<i>Editorial Commentary<\/i>\n                    : Superior Capsular Reconstruction Graft Continuity on Magnetic Resonance Imaging Does Not Necessarily Reflect Structural Competence"],"prefix":"10.1002","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4204-3482","authenticated-orcid":false,"given":"Albert","family":"Lin","sequence":"first","affiliation":[{"name":"University of Pittsburgh Medical Center  Pittsburgh Pennsylvania U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamad Y.","family":"Fares","sequence":"additional","affiliation":[{"name":"University of Pittsburgh Medical Center  Pittsburgh Pennsylvania U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,9,2]]},"reference":[{"key":"e_1_2_3_2_1","doi-asserted-by":"crossref","first-page":"1423","DOI":"10.1177\/0363546516631751","article-title":"Biomechanical role of capsular continuity in superior capsule reconstruction for irreparable tears of the supraspinatus tendon","volume":"44","author":"Mihata T","year":"2016","journal-title":"Am J Sports Med."},{"key":"e_1_2_3_3_1","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1007\/s12178-021-09714-7","article-title":"Treatment options for massive irreparable rotator cuff tears","volume":"14","author":"Kucirek NK","year":"2021","journal-title":"Curr Rev Musculoskelet Med."},{"key":"e_1_2_3_4_1","doi-asserted-by":"crossref","first-page":"1476","DOI":"10.1016\/j.jse.2022.12.010","article-title":"Postoperative graft integrity affects clinical outcomes after superior capsule reconstruction using fascia lata autograft in posterior\u2010superior rotator cuff tears: A multicenter study","volume":"32","author":"Hasegawa A","year":"2023","journal-title":"J Shoulder Elbow Surg."},{"key":"e_1_2_3_5_1","doi-asserted-by":"crossref","first-page":"3109","DOI":"10.1016\/j.arthro.2022.06.033","article-title":"Graft healing is more important than graft technique: Superior capsular reconstruction versus bridging grafts\u2014A prospective randomized controlled trial","volume":"38","author":"Ono Y","year":"2022","journal-title":"Arthroscopy."},{"key":"e_1_2_3_6_1","first-page":"xx","article-title":"Progressive thinning of autologous fascia Lata graft is associated with graft Retear after superior capsular reconstruction: A 5\u2010year magnetic resonance imaging study","author":"Baek CH","year":"2026","journal-title":"Arthroscopy."},{"key":"e_1_2_3_7_1","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1177\/03635465241298898","article-title":"Long\u2010term clinical and structural outcomes of arthroscopic superior capsule reconstruction for irreparable rotator cuff tears: 10\u2010year follow\u2010up","volume":"53","author":"Mihata T","year":"2025","journal-title":"Am J Sports Med."},{"key":"e_1_2_3_8_1","doi-asserted-by":"crossref","first-page":"2248","DOI":"10.1177\/0363546512456195","article-title":"Superior capsule reconstruction to restore superior stability in irreparable rotator cuff tears: A biomechanical cadaveric study","volume":"40","author":"Mihata T","year":"2012","journal-title":"Am J Sports Med."},{"key":"e_1_2_3_9_1","doi-asserted-by":"crossref","first-page":"2041","DOI":"10.1016\/j.jse.2020.12.016","article-title":"Evaluating the role of graft integrity on outcomes: Clinical and imaging results following superior capsular reconstruction","volume":"30","author":"LaBelle MW","year":"2021","journal-title":"J Shoulder Elbow Surg."},{"key":"e_1_2_3_10_1","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1002\/arj.70063","article-title":"Superior capsular reconstruction with acellular dermal allograft improves midterm clinical outcomes but is associated with high rates of graft failure and progression of cuff tear arthropathy","volume":"42","author":"Cognetti DJ","year":"2026","journal-title":"Arthroscopy."},{"key":"e_1_2_3_11_1","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.arthro.2021.06.018","article-title":"Improved outcomes following arthroscopic superior capsular reconstruction may not be associated with changes in shoulder kinematics: An in vivo study","volume":"38","author":"Kane GE","year":"2022","journal-title":"Arthroscopy."},{"key":"e_1_2_3_12_1","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1002\/arj.70013","article-title":"Arthroscopic biologic tuberoplasty with a dermal allograft leads to significant improvement in functional outcomes in patients with massive, irreparable rotator cuff tears","volume":"42","author":"Mirzayan R","year":"2026","journal-title":"Arthroscopy."},{"key":"e_1_2_3_13_1","doi-asserted-by":"crossref","first-page":"3065","DOI":"10.1177\/03635465241278358","article-title":"Patients with graft tears leaving the tuberosity covered have similar functional outcomes to those with an intact graft after superior capsular reconstruction","volume":"52","author":"Mirzayan R","year":"2024","journal-title":"Am J Sports Med."},{"key":"e_1_2_3_14_1","doi-asserted-by":"crossref","first-page":"100907","DOI":"10.1016\/j.asmr.2024.100907","article-title":"The insertion of a subacromial balloon spacer can provide symptom relief and functional improvement at a minimum 5\u2010year follow\u2010up in patients with massive irreparable rotator cuff tears","volume":"6","author":"Fares MY","year":"2024","journal-title":"Arthrosc Sports Med Rehabil."},{"key":"e_1_2_3_15_1","doi-asserted-by":"crossref","first-page":"5005","DOI":"10.1016\/j.arthro.2025.06.009","article-title":"Isolated subacromial balloon spacer implantation for massive irreparable rotator cuff tears is associated with improvement in pain and function at a minimum 1\u2010year follow\u2010up","volume":"41","author":"Fares MY","year":"2025","journal-title":"Arthroscopy."},{"key":"e_1_2_3_16_1","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.2106\/JBJS.21.00667","article-title":"InSpace implant compared with partial repair for the treatment of full\u2010thickness massive rotator cuff tears: A multicenter, single\u2010blinded, randomized controlled trial","volume":"104","author":"Verma N","year":"2022","journal-title":"J Bone Joint Surg Am."},{"key":"e_1_2_3_17_1","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.2106\/00004623-199609000-00015","article-title":"Magnetic resonance imaging for evaluation of failed repairs of the rotator cuff. Relationship to operative findings","volume":"78","author":"Gaenslen ES","year":"1996","journal-title":"J Bone Joint Surg Am"},{"key":"e_1_2_3_18_1","first-page":"232596712311933","article-title":"Evaluation of a new MRI\u2010based classification of graft status after superior capsule reconstruction","volume":"11","author":"Lee JB","year":"2023","journal-title":"Orthop J Sports Med"},{"key":"e_1_2_3_19_1","doi-asserted-by":"crossref","first-page":"953","DOI":"10.2106\/00004623-200705000-00006","article-title":"Repair integrity and functional outcome after arthroscopic double\u2010row rotator cuff repair. A prospective outcome study","volume":"89","author":"Sugaya H","year":"2007","journal-title":"J Bone Joint Surg Am."},{"key":"e_1_2_3_20_1","doi-asserted-by":"crossref","first-page":"219","DOI":"10.2106\/00004623-200402000-00002","article-title":"The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears","volume":"86","author":"Galatz LM","year":"2004","journal-title":"J Bone Joint Surg Am."}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/arj.70500","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/arj.70500","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/arj.70500","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T07:03:01Z","timestamp":1788332581000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1002\/arj.70500"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,2]]},"references-count":19,"alternative-id":["10.1002\/arj.70500"],"URL":"https:\/\/doi.org\/10.1002\/arj.70500","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,2]]},"assertion":[{"value":"2026-09-02","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"arj.70500"}}