{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T05:38:41Z","timestamp":1792474721609,"version":"4.5.0"},"reference-count":17,"publisher":"Wiley","license":[{"start":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T00:00:00Z","timestamp":1792368000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T00:00:00Z","timestamp":1792368000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["arthroscopyjournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["arthrosc. tech."],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The all\u2010inside anterior cruciate ligament reconstruction technique is characterized by closed bone sockets for anterior cruciate ligament graft passage and typically adopts suspensory fixation instead of screw fixation. Inaccurate determination of the intra\u2010articular length (IAL) of the graft is associated with an elevated risk of graft \u201cbottoming out\u201d and excessive length consumption of the tibial sockets. Notably, the IAL is dependent on the patient's knee dimensions and intraoperative tunnel positioning, thus requiring individualized measurement. Herein, we propose an intraoperative method for accurate IAL measurement in all\u2010inside anterior cruciate ligament reconstruction, which enables the creation of bone sockets with appropriate lengths based on individual IAL values. This technique effectively mitigates graft\u2010tunnel mismatch and improves the stability of graft fixation, thereby optimizing the clinical outcomes of the all\u2010inside anterior cruciate ligament reconstruction.<\/jats:p>","DOI":"10.1002\/atn2.70284","type":"journal-article","created":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T04:49:51Z","timestamp":1792471791000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["All\u2010Inside Anterior Cruciate Ligament Reconstruction With Accurate Measurement Technique"],"prefix":"10.1002","author":[{"given":"Daoliang","family":"Xu","sequence":"first","affiliation":[{"name":"Department of Orthopaedics The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University  Wenzhou Zhejiang China"},{"name":"Key Laboratory of Orthopedics of Zhejiang Province  Wenzhou Zhejiang China"},{"name":"The Second Clinical School of Medicine Wenzhou Medical University  Wenzhou Zhejiang China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University  Wenzhou Zhejiang China"},{"name":"Key Laboratory of Orthopedics of Zhejiang Province  Wenzhou Zhejiang China"},{"name":"The Second Clinical School of Medicine Wenzhou Medical University  Wenzhou Zhejiang China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian","family":"Lin","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University  Wenzhou Zhejiang China"},{"name":"Key Laboratory of Orthopedics of Zhejiang Province  Wenzhou Zhejiang China"},{"name":"The Second Clinical School of Medicine Wenzhou Medical University  Wenzhou Zhejiang China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renjie","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics The Third People's Hospital of Cangnan  Wenzhou Zhejiang China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhikai","family":"Lu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics No. 906 Hospital of Joint Logistic Support Force of PLA  Ningbo Zhejiang China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yulong","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University  Wenzhou Zhejiang China"},{"name":"Key Laboratory of Orthopedics of Zhejiang Province  Wenzhou Zhejiang China"},{"name":"The Second Clinical School of Medicine Wenzhou Medical University  Wenzhou Zhejiang China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6462-7767","authenticated-orcid":false,"given":"Xiaoyun","family":"Pan","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University  Wenzhou Zhejiang China"},{"name":"Key Laboratory of Orthopedics of Zhejiang Province  Wenzhou Zhejiang China"},{"name":"The Second Clinical School of Medicine Wenzhou Medical University  Wenzhou Zhejiang China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,10,19]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/0749-8063(95)90104-3"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2006.06.003"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2011.02.008"},{"key":"e_1_2_6_5_1","first-page":"e35964","article-title":"Gross measurement of intraarticular graft length in all\u2010inside anterior cruciate ligament reconstruction","volume":"15","author":"Koukoulias NE","year":"2023","journal-title":"Cureus"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2022.06.001"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jor.2017.03.002"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2024.03.011"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2021.03.077"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2017.08.283"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1177\/23259671211006521"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2015.08.014"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2024.01.044"},{"key":"e_1_2_6_14_1","first-page":"232596711881631","article-title":"Graft\u2010tunnel mismatch in endoscopic ACL reconstruction: Reliability of measuring tunnel lengths and intra\u2010articular distance","volume":"6","author":"Dwyer T","year":"2018","journal-title":"Orthop J Sports Med"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-020-02798-w"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-018-5275-x"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1055\/a-1281-8627"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546508320572"}],"container-title":["Arthroscopy Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/atn2.70284","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/atn2.70284","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/atn2.70284","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T04:49:58Z","timestamp":1792471798000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1002\/atn2.70284"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,19]]},"references-count":17,"alternative-id":["10.1002\/atn2.70284"],"URL":"https:\/\/doi.org\/10.1002\/atn2.70284","archive":["Portico"],"relation":{},"ISSN":["2212-6287","2212-6287"],"issn-type":[{"value":"2212-6287","type":"print"},{"value":"2212-6287","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,19]]},"assertion":[{"value":"2026-01-26","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-30","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-10-19","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70284"}}