{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T08:02:06Z","timestamp":1769155326391,"version":"3.49.0"},"reference-count":37,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2011,6,6]],"date-time":"2011-06-06T00:00:00Z","timestamp":1307318400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bioelectromagnetics"],"published-print":{"date-parts":[[2012,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Terrestrial Trunked Radio (TETRA) technology (\u201cAirwave\u201d) has led to public concern because of its potential interference with electrical activity in the brain. The present study is the first to examine whether acute exposure to a TETRA base station signal has an impact on cognitive functioning and physiological responses. Participants were exposed to a 420\u2009MHz TETRA signal at a power flux density of 10\u2009mW\/m<jats:sup>2<\/jats:sup> as well as sham (no signal) under double\u2010blind conditions. Fifty\u2010one people who reported a perceived sensitivity to electromagnetic fields as well as 132 controls participated in a double\u2010blind provocation study. Forty\u2010eight sensitive and 132 control participants completed all three sessions. Measures of short\u2010term memory, working memory, and attention were administered while physiological responses (blood volume pulse, heart rate, skin conductance) were monitored. After applying exclusion criteria based on task performance for each aforementioned cognitive measure, data were analyzed for 36, 43, and 48 sensitive participants for these respective tasks and, likewise, 107,125, and 129 controls. We observed no differences in cognitive performance between sham and TETRA exposure in either group; physiological response also did not differ between the exposure conditions. These findings are similar to previous double\u2010blind studies with other mobile phone signals (900\u20132100\u2009MHz), which could not establish any clear evidence that mobile phone signals affect health or cognitive function. Bioelectromagnetics  33:23\u201339, 2012. \u00a9 2011 Wiley Periodicals, Inc.<\/jats:p>","DOI":"10.1002\/bem.20681","type":"journal-article","created":{"date-parts":[[2011,6,6]],"date-time":"2011-06-06T18:45:47Z","timestamp":1307385947000},"page":"23-39","source":"Crossref","is-referenced-by-count":23,"title":["Cognitive and physiological responses in humans exposed to a TETRA base station signal in relation to perceived electromagnetic hypersensitivity"],"prefix":"10.1002","volume":"33","author":[{"given":"Denise","family":"Wallace","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stacy","family":"Eltiti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna","family":"Ridgewell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kelly","family":"Garner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Riccardo","family":"Russo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francisco","family":"Sepulveda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stuart","family":"Walker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Terence","family":"Quinlan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandra","family":"Dudley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sithu","family":"Maung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roger","family":"Deeble","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elaine","family":"Fox","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,6,6]]},"reference":[{"key":"e_1_2_7_2_1","unstructured":"Advisory Group on Non\u2010Ionising Radiation.2001.Possible Health Effects from Terrestrial Trunked Radio (TETRA): Report of an Advisory Group on Non\u2010Ionizing Radiation. National Radiological Protection Board (NRPB). 1\u201086.http:\/\/www.hpa.org.uk\/web\/HPAwebFile\/HPAweb_C\/1194947336937(Last Accessed 7 December 2009)."},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20333"},{"key":"e_1_2_7_4_1","volume-title":"TETRA base station emulator at the University of Essex, Technical Reference Manual. Version 1.4","author":"Belloul B","year":"2008"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1080\/001401397187919"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20321"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/acp.1425"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.3758\/BF03196772"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20352"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20583"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neures.2005.07.003"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1289\/ehp.10286"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20279"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20504"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20287"},{"key":"e_1_2_7_16_1","first-page":"15","volume-title":"Proceedings of the International Workshop on EMF Hypersensitivity","author":"Hansson Mild K","year":"2006"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3999(99)00048-3"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20415"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20635"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20419"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20458"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-8760(01)00141-6"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.73"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1136\/oem.2010.055889"},{"key":"e_1_2_7_25_1","unstructured":"Police Federation News.2005.Airwave Keeping the Lines of Communication Open?http:\/\/www.polfed.org\/PFNews_Airwave_Issue24.pdf(Last Accessed 3 June 2009)."},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1080\/095530099140375"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1289\/ehp.8934"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20388"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20571"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20193"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-8760(03)00145-4"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/0749-596X(89)90040-5"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20374"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1289\/ehp.0901416"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.5014\/ajot.62.5.588"},{"key":"e_1_2_7_36_1","volume-title":"Wechsler Adult Intelligence Scale\u2010Revised","author":"Wechsler D","year":"1981"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20195"},{"key":"e_1_2_7_38_1","volume-title":"Effects of Global Communication System radio\u2010frequency fields on well being and cognitive functions of human subjects with and without subjective complaints","author":"Zwamborn A","year":"2003"}],"container-title":["Bioelectromagnetics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fbem.20681","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/bem.20681","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T20:45:01Z","timestamp":1696970701000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/bem.20681"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,6,6]]},"references-count":37,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2012,1]]}},"alternative-id":["10.1002\/bem.20681"],"URL":"https:\/\/doi.org\/10.1002\/bem.20681","archive":["Portico"],"relation":{},"ISSN":["0197-8462","1521-186X"],"issn-type":[{"value":"0197-8462","type":"print"},{"value":"1521-186X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,6,6]]}}}