{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T01:17:36Z","timestamp":1788484656891,"version":"build-2803163510"},"reference-count":35,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2015,5,14]],"date-time":"2015-05-14T00:00:00Z","timestamp":1431561600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"Mugla Sitki Kocman University Research Fund","award":["2013\/111"],"award-info":[{"award-number":["2013\/111"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bioelectromagnetics"],"published-print":{"date-parts":[[2015,9]]},"abstract":"<jats:sec><jats:label\/><jats:p>Although a large number of exposure studies have been carried out to investigate possible detrimental effects of a power\u2010line frequency magnetic field (PF\u2010MF; 50\u201360\u2009Hz) on living organisms, there is no consensus in reported results. Recent research suggested that short\u2010term exposure to a 50\u2009Hz PF\u2010MF can have a greater effect than long\u2010term exposure. In our study, we aimed to investigate the possible effect of short\u2010term 50\u2009Hz PF\u2010MF exposure on central, peripheral, and autonomic nervous systems through electroencephalogram (EEG), nerve conduction velocity (NCV), and heart rate variability (HRV) measurements. To that end, Wistar albino rats and sciatic nerves gathered from the rats were exposed to a 50\u2009Hz, 0.3\u2009mT MF, and changes on EEG, NCV, and HRV were investigated. According to data we gathered, MF frequency and magnetic flux density that we applied did not affect EEG, NCV, or HRV. The reason for conflicting results gathered from MF exposure studies may be that the nervous system can be affected by a specific MF frequency and magnetic flux density, but that different MF exposures do not affect it. Moreover, exposure duration to MF may also have influenced results. Bioelectromagnetics. 36:420\u2013429, 2015. \u00a9 2015 Wiley Periodicals, Inc.<\/jats:p><\/jats:sec>","DOI":"10.1002\/bem.21922","type":"journal-article","created":{"date-parts":[[2015,5,14]],"date-time":"2015-05-14T11:32:18Z","timestamp":1431603138000},"page":"420-429","source":"Crossref","is-referenced-by-count":4,"title":["Investigation of effects of short\u2010term exposure to 50\u2009HZ magnetic field on central, peripheral, and autonomic nervous systems in rats"],"prefix":"10.1002","volume":"36","author":[{"given":"Onur","family":"Elmas","sequence":"first","affiliation":[{"name":"Department of Physiology Mugla Sitki Kocman University Faculty of Medicine Mugla Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Selcuk","family":"Comlekci","sequence":"additional","affiliation":[{"name":"Department of Electronics and Communication Engineering Suleyman Demirel University Isparta Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2015,5,14]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/0006-8993(89)90025-5"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/0140-6736(91)92336-Z"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/1469-8986.3510127"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1539\/joh.47.391"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.2478\/v10001-006-0001-1"},{"key":"e_1_2_5_7_1","first-page":"99","article-title":"Synaptic neurone activity under applied 50\u2009Hz alternating magnetic fields. Comparative Biochemistry and Physiology Part C: Pharmacology","volume":"124","author":"Calvo A","year":"1999","journal-title":"Toxicol Endocrinol"},{"key":"e_1_2_5_8_1","first-page":"118","article-title":"Vagal modulation of resting heart rate in rats: The role of stress, psychosocial factors, and physical exercise","volume":"24","author":"Carnevali L","year":"2014","journal-title":"Front Physiol"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.3109\/15368378.2012.662190"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1177\/0748233710381893"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11517-009-0525-1"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1521-186X(1997)18:1<28::AID-BEM6>3.0.CO;2-7"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0197-4580(00)00108-1"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1080\/19338244.2011.578680"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1590\/S0103-84782013005000117"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neulet.2005.02.072"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.2250150508"},{"key":"e_1_2_5_18_1","first-page":"791","article-title":"A case\u2010control study of motor neurone disease: Its relation to heritability, and occupational exposures, particularly to solvents","volume":"49","author":"Gunnarsson L","year":"1992","journal-title":"Br J Ind Med"},{"key":"e_1_2_5_19_1","unstructured":"IEEE (Institute of Electronics and Electrical Engineers).2005. IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields 3\u2009kHz to 300\u2009GHz IEEE Std C95."},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1474-8673.2004.00328.x"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.aje.a009654"},{"key":"e_1_2_5_22_1","doi-asserted-by":"publisher","DOI":"10.1017\/S1461145711000848"},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1566-0702(02)00296-5"},{"key":"e_1_2_5_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bcp.2010.10.002"},{"key":"e_1_2_5_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinph.2003.12.023"},{"key":"e_1_2_5_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0031-9384(03)00206-3"},{"key":"e_1_2_5_27_1","first-page":"441","article-title":"The cardiovascular response to an acute 1800\u2010microT, 60\u2010Hz magnetic field exposure in humans","volume":"10","author":"McNamee D","year":"2009","journal-title":"Int Arch Occup Environ Health"},{"key":"e_1_2_5_28_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-4159.2005.03167.x"},{"key":"e_1_2_5_29_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ede.0000142147.49297.9d"},{"key":"e_1_2_5_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.physbeh.2014.05.037"},{"key":"e_1_2_5_31_1","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/27\/1\/007"},{"key":"e_1_2_5_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1350-4533(99)00062-4"},{"key":"e_1_2_5_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1521-186X(1998)19:2<98::AID-BEM7>3.0.CO;2-Z"},{"key":"e_1_2_5_34_1","doi-asserted-by":"publisher","DOI":"10.1097\/00001648-199807000-00009"},{"key":"e_1_2_5_35_1","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.aje.a117669"},{"key":"e_1_2_5_36_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20039"}],"container-title":["Bioelectromagnetics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fbem.21922","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/bem.21922","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,6]],"date-time":"2023-10-06T15:38:06Z","timestamp":1696606686000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/bem.21922"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,5,14]]},"references-count":35,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2015,9]]}},"alternative-id":["10.1002\/bem.21922"],"URL":"https:\/\/doi.org\/10.1002\/bem.21922","archive":["Portico"],"relation":{},"ISSN":["0197-8462","1521-186X"],"issn-type":[{"value":"0197-8462","type":"print"},{"value":"1521-186X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,5,14]]}}}