{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,25]],"date-time":"2026-04-25T09:49:48Z","timestamp":1777110588131,"version":"3.51.4"},"reference-count":15,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2005,10,19]],"date-time":"2005-10-19T00:00:00Z","timestamp":1129680000000},"content-version":"vor","delay-in-days":5040,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bioelectromagnetics"],"published-print":{"date-parts":[[1992,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Sixty\u2010Hz magnetic field exposures were measured for 45 adult residents of Maine. Thirty of the subjects resided near rights\u2010of\u2010way (ROWs) with either 345\u2010 and 115\u2010kV transmission lines, or ROWs with only 115\u2010kV transmission lines; fifteen resided far from any transmission lines. Personal exposure data for a single 24\u2010hour period was acquired with the EMDEX. The EMDEX's event\u2010marker button was used to partition exposures into Home and Away components. Also, three area measurements were taken for each subject during the personal exposure measurement period: 1) 24\u2010hr fixed\u2010site bedroom measurement with a second EMDEX; 2) Spot measurements in at least three rooms of every residence; and 3) Spot measurements outside each residence. Residence near transmission lines highly loaded during the measurement period was associated with increased Home and Total exposure relative to a far\u2010away population. Average exposure level while away from home was uniform (at about 2 mG) throughout the study population. On a quantitative level, Home exposure was correlated equivalently with Spot\u2010In (r = .70) and the 24\u2010hr fixed site measurement (r = .68). Correlations of area measurements with Total exposure were weaker because of the dilution effect of Away exposure (r = .64 for Spot\u2010In; r = .61 for 24\u2010h Bedroom). Away and Home exposures were not correlated (r = .14), which reinforced our confidence that the participants used the EMDEX correctly. The data suggest the need for caution before inferences are drawn about total personal exposure from area measurements. The study demonstrates the feasibility of obtaining valid measures of magnetic\u2010field exposure with the personal exposure monitors that have been developed.<\/jats:p>","DOI":"10.1002\/bem.2250130106","type":"journal-article","created":{"date-parts":[[2006,2,3]],"date-time":"2006-02-03T19:51:23Z","timestamp":1138996283000},"page":"35-55","source":"Crossref","is-referenced-by-count":36,"title":["Magnetic field exposure assessment for adult residents of maine who live near and far away from overhead transmission lines"],"prefix":"10.1002","volume":"13","author":[{"given":"Robert","family":"Kavet","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. Michael","family":"Silva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Thornton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,10,19]]},"reference":[{"key":"e_1_2_1_2_1","unstructured":"AfifiAA BanksRS KheifetsLI NewmanB(1990): Proceding: Discussion of an EMF Protocol Electric Power Research Institute Report EN\u20106829 Palo Alto CA."},{"key":"e_1_2_1_3_1","doi-asserted-by":"publisher","DOI":"10.1080\/15298668891379981"},{"key":"e_1_2_1_4_1","unstructured":"Enertech (1988):SilvaJM RutterDA HummonNP HooperHC ZaffanellaLE DenoDW: EXPOCALC Version 2. 1: An Exposure Assessment Tool for Transmission Line Electric and Magnetic Fields. User's Manual and Documentation Electric Power Research Institute Report EA\u20105765CCML Palo Alto CA."},{"key":"e_1_2_1_5_1","unstructured":"Enertech (1989): \u201cEMDEX System Manuals \u201d Vol 1: \u201cUser's Manual\u201d; Vol 2: \u201cTechnical Reference Manual.\u201d Electric Power Research Institute Report EN\u20106518 Palo Alto CA."},{"key":"e_1_2_1_6_1","unstructured":"ESEERCO (1989): Magnetic field levels associated with 345 kV transmission circuits in New York State Prepared by Central Hudson Gas and Electric Corporation Consolidated Edison Company of New York Inc. Long Island Lighting Company New York Power Authority New York State Electric and Gas Corporation Niagara Mohawk Power Corporation Orange and Rockland Utilities Inc. Rochester Gas and Electric Corporation; Coordinated through Empire State Electric Energy Research Corporation June 1989."},{"key":"e_1_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.2250080402"},{"key":"e_1_2_1_8_1","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.aje.a114943"},{"key":"e_1_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.aje.a114932"},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.1109\/61.19237"},{"key":"e_1_2_1_11_1","volume-title":"Biometry: The Principles and Practice of Statistics in Biological Research","author":"Sokal RR","year":"1981"},{"key":"e_1_2_1_12_1","volume-title":"The Use of Time","author":"Szalai A","year":"1972"},{"key":"e_1_2_1_13_1","unstructured":"U. Mich. (1981): \u201cTime Use in Economics and Social Accounts.\u201d Institute for Social Research University of Michigan Ann Arbor MI."},{"key":"e_1_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.aje.a112681"},{"key":"e_1_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/ijc.20845"},{"key":"e_1_2_1_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF00048275"}],"container-title":["Bioelectromagnetics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fbem.2250130106","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/bem.2250130106","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T12:37:07Z","timestamp":1698064627000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/bem.2250130106"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1992,1]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1992,1]]}},"alternative-id":["10.1002\/bem.2250130106"],"URL":"https:\/\/doi.org\/10.1002\/bem.2250130106","archive":["Portico"],"relation":{},"ISSN":["0197-8462","1521-186X"],"issn-type":[{"value":"0197-8462","type":"print"},{"value":"1521-186X","type":"electronic"}],"subject":[],"published":{"date-parts":[[1992,1]]}}}