{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T14:51:34Z","timestamp":1788792694227,"version":"build-2803163510"},"reference-count":44,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82304891"],"award-info":[{"award-number":["82304891"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["analyticalsciencejournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Luminescence"],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>\n                    Anthrax is an acute infectious disease caused by\n                    <jats:styled-content style=\"fixed-case\">\n                      <jats:italic>Bacillus anthracis<\/jats:italic>\n                    <\/jats:styled-content>\n                    . It can damage the skin, lungs, and intestines of humans and animals and can be fatal in severe cases. Therefore, it is of great significance to develop highly efficient detection methods. Pyridine\u20102,6\u2010dicarboxylic acid (DPA), a major component of bacterial spores, can be used as a biomarker for the detection of anthrax. However, existing biological and chemical detection methods have shortcomings. Biological methods often involve lengthy procedures, complex equipment, and expensive reagents. In chemical methods, most fluorescence sensors for DPA detection have low sensitivity, precision, and accuracy. To solve this, a dual\u2010signal\u2010responsive ratiometric fluorescence sensor was designed. First, Bio\u2010MOF was synthesized with Zn\n                    <jats:sup>2+<\/jats:sup>\n                    , adenine, and 1,3,5\u2010benzenetricarboxylic acid. Then, Tb\n                    <jats:sup>3+<\/jats:sup>\n                    was introduced via cation exchange, and 1\u2010Hydroxypyrene (1\u2010OHP) was introduced via hydrogen bonds to get 1\u2010OHP\/Tb@Bio\u2010MOF. With DPA, Tb\n                    <jats:sup>3+<\/jats:sup>\n                    forms a complex, enhancing its emission (\u201cturn\u2010on\u201d), while DPA reduces 1\u2010OHP emission (\u201cturn\u2010off\u201d) via IFE and PET. This sensor detects DPA in serum sensitively and selectively, and a DPA\u2010monitoring logic gate was made. Also, a paper\u2010based sensor (1\u2010OHP\/Tb\u2010MOF@CP) was prepared by blending.\n                  <\/jats:p>","DOI":"10.1002\/bio.70493","type":"journal-article","created":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T10:16:25Z","timestamp":1777630585000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A Ln\u2010MOF Sensor Based on Dual\u2010Signal Response and Logic Gating for the Ratio Fluorescence Detection of Anthrax Biomarkers"],"prefix":"10.1002","volume":"41","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-3956-772X","authenticated-orcid":false,"given":"Yuhang","family":"Zhang","sequence":"first","affiliation":[{"name":"Research Center for Precision Medication of Chinese Medicine, College of Pharmacy Hunan University of Chinese Medicine  Changsha China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiang","family":"Hou","sequence":"additional","affiliation":[{"name":"Research Center for Precision Medication of Chinese Medicine, College of Pharmacy Hunan University of Chinese Medicine  Changsha China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenwen","family":"Deng","sequence":"additional","affiliation":[{"name":"Institute of Traditional Chinese Medicine Health Industry China Academy of Chinese Medical Sciences  Nanchang China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7255-6049","authenticated-orcid":false,"given":"Zhixin","family":"Wang","sequence":"additional","affiliation":[{"name":"Institute of Traditional Chinese Medicine Health Industry China Academy of Chinese Medical Sciences  Nanchang China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"QuTong","family":"Zheng","sequence":"additional","affiliation":[{"name":"Research Center for Precision Medication of Chinese Medicine, College of Pharmacy Hunan University of Chinese Medicine  Changsha China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,5,1]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1039\/d4nr01175a"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1039\/c9cc08206az"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1039\/D3QI01852K"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cej.2024.149229"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pntd.0012122"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.snb.2020.128156"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.snb.2021.130467"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhazmat.2019.05.108"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1021\/acs.analchem.8b00050"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.3390\/ijms241914792"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ceramint.2024.09.334"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.aca.2023.342131"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1021\/acs.jcim.0c00076"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1021\/jacs.7b00867"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.talanta.2025.128176"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1039\/c8nj04046j"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1039\/c7cc07344e"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.saa.2024.125425"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cclet.2022.108009"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00604\u2010020\u20104113\u20102"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1021\/acs.analchem.0c00499"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1039\/d0tc00364f"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.aca.2023.342143"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.snb.2023.133596"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ccr.2020.213709"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ccr.2023.215101"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2024.e27640"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jssc.2021.122081"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1039\/d0qi01153c"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1021\/acsami.3c12756"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/mop.70190"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.snb.2018.03.128"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1021\/acssensors.3c02083"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.saa.2021.119901"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1021\/acsanm.3c06145"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.microc.2025.114058"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00216\u2010021\u201003369\u20106"},{"key":"e_1_2_10_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.talanta.2025.127753"},{"key":"e_1_2_10_40_1","doi-asserted-by":"publisher","DOI":"10.1039\/c8ta02857e"},{"key":"e_1_2_10_41_1","doi-asserted-by":"publisher","DOI":"10.1002\/adma.201802329"},{"key":"e_1_2_10_42_1","doi-asserted-by":"publisher","DOI":"10.1021\/acsami.9b11650"},{"key":"e_1_2_10_43_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0205986"},{"key":"e_1_2_10_44_1","doi-asserted-by":"publisher","DOI":"10.1021\/acs.inorgchem.5c04278"},{"key":"e_1_2_10_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.optmat.2020.110006"}],"container-title":["Luminescence"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/bio.70493","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/bio.70493","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/bio.70493","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T01:38:40Z","timestamp":1779759520000},"score":1,"resource":{"primary":{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/10.1002\/bio.70493"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":44,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["10.1002\/bio.70493"],"URL":"https:\/\/doi.org\/10.1002\/bio.70493","archive":["Portico"],"relation":{},"ISSN":["1522-7235","1522-7243"],"issn-type":[{"value":"1522-7235","type":"print"},{"value":"1522-7243","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5]]},"assertion":[{"value":"2025-11-25","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-17","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-05-01","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70493"}}