{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,28]],"date-time":"2024-09-28T10:10:25Z","timestamp":1727518225504},"reference-count":24,"publisher":"Oxford University Press (OUP)","issue":"9","license":[{"start":{"date-parts":[[1991,9,1]],"date-time":"1991-09-01T00:00:00Z","timestamp":683683200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[1991,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>The techniques of ultrasonographic and hookwire localization biopsy of impalpable breast lesions detected by a large breast screening unit during its first year of operation are described. Hookwire localization (HL) was performed using mammography. Ultrasonographic localization (UL) was used for lesions readily detectable by ultrasonography by marking the skin directly over the lesion and calculating its depth below the surface. UL is not appropriate when microcalcification is the sole mammographic abnormality. Localization was required for 150 of the 191 (78.5 per cent) screen-detected lesions. HL was used for 94 (62.7 per cent) and UL for 56 (37.3 per cent). Four lesions were missed by HL, none by UL; 35 per cent of lesions removed by HL and 39 per cent by UL were malignant, giving benign:malignant biopsy ratios of 1.8:1 and 1.5:1 respectively. Only 22 per cent of the patients required overnight hospital stay. Localization biopsy plays a major role in the surgery for screen-detected lesions and, where applicable, UL is the technique of choice.<\/jats:p>","DOI":"10.1002\/bjs.1800780926","type":"journal-article","created":{"date-parts":[[2007,3,3]],"date-time":"2007-03-03T16:17:48Z","timestamp":1172938668000},"page":"1113-1115","source":"Crossref","is-referenced-by-count":11,"title":["Technique and results of localization biopsy in a breast screening programme"],"prefix":"10.1093","volume":"78","author":[{"given":"I D","family":"Campbell","sequence":"first","affiliation":[{"name":"University Surgical Unit, Southampton General Hospital , Southampton,","place":["UK"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R","family":"Coddington","sequence":"additional","affiliation":[{"name":"Department of Pathology, Southampton General Hospital , Southampton,","place":["UK"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J","family":"Theaker","sequence":"additional","affiliation":[{"name":"Department of Pathology, Southampton General Hospital , Southampton,","place":["UK"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G T","family":"Royle","sequence":"additional","affiliation":[{"name":"Southampton and Salisbury Breast Screening Unit, Royal South Hants Hospital , Southampton,","place":["UK"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C M","family":"Rubin","sequence":"additional","affiliation":[{"name":"Southampton and Salisbury Breast Screening Unit, Royal South Hants Hospital , Southampton,","place":["UK"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P B","family":"Guyer","sequence":"additional","affiliation":[{"name":"Southampton and Salisbury Breast Screening Unit, Royal South Hants Hospital , Southampton,","place":["UK"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I","family":"Taylor","sequence":"additional","affiliation":[{"name":"Southampton and Salisbury Breast Screening Unit, Royal South Hants Hospital , Southampton,","place":["UK"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[1991,9,1]]},"reference":[{"key":"2024092809401205500_bib1","first-page":"115","article-title":"Breast biopsy and guidance for occult lesions","volume":"70","author":"Leis","year":"1985","journal-title":"Int Surg"},{"key":"2024092809401205500_bib2","first-page":"439","article-title":"Technique and guidelines for needle localization biopsy of non-palpable lesions of the breast","volume":"167","author":"Wilhelm","year":"1988","journal-title":"Surg Gynecol Obstet"},{"key":"2024092809401205500_bib3","first-page":"269","article-title":"The biopsy of impalpable lesions of the breast","volume":"164","author":"Leinster","year":"1987","journal-title":"Surg Gynecol Obstet"},{"key":"2024092809401205500_bib4","first-page":"329","article-title":"Intraoperative localisation of occult breast tumours","volume":"28","author":"Mahoney","year":"1985","journal-title":"Can J Surg"},{"key":"2024092809401205500_bib5","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1177\/014107688708001106","article-title":"X-ray and ultrasound localization of non-palpable breast lesions and difficulties in management","volume":"80","author":"Tate","year":"1987","journal-title":"J R Soc Med"},{"volume-title":"Breast Cancer Screening: Report to the Health Ministers of England, Wales, Scotland and Northern Ireland by a Working Group chaired by Professor Sir Patrick Forrest","year":"1987","key":"2024092809401205500_bib6"},{"key":"2024092809401205500_bib7","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/0301-5629(88)90060-9","article-title":"Can microcalcifications located within breast carcinomas be detected by ultrasound imaging?","volume":"14","author":"Kasumi","year":"1988","journal-title":"Ultrasound Med Biol"},{"key":"2024092809401205500_bib8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0009-9260(05)80920-1","article-title":"Starting from scratch \u2014 some problems with Forrest","volume":"41","author":"Guyer","year":"1990","journal-title":"Clin Radiol"},{"key":"2024092809401205500_bib9","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1056\/NEJM197607292950506","article-title":"Preoperative localisation of nonpalpable breast lesions demonstrated by mammography","volume":"295","author":"Frank","year":"1976","journal-title":"N Engl J Med"},{"key":"2024092809401205500_bib10","doi-asserted-by":"crossref","first-page":"586","DOI":"10.2214\/ajr.138.3.586","article-title":"Versatile spring hookwire breast lesion localiser","volume":"138","author":"Kopans","year":"1982","journal-title":"AJR"},{"key":"2024092809401205500_bib11","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/0301-5629(88)90043-9","article-title":"Ultrasound: an alternative to X-ray guided needle localisation of non-palpable breast masses","volume":"14","author":"Schwartz","year":"1988","journal-title":"Ultrasound Med Biol"},{"key":"2024092809401205500_bib12","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1002\/bjs.1800750319","article-title":"Ultrasound mammography in the management of breast cancer","volume":"75","author":"Warwick","year":"1988","journal-title":"Br J Surg"},{"key":"2024092809401205500_bib13","doi-asserted-by":"crossref","first-page":"929","DOI":"10.2214\/ajr.141.5.929","article-title":"Transection of the localization hooked wire during breast biopsy","volume":"141","author":"Homer","year":"1983","journal-title":"AJR"},{"key":"2024092809401205500_bib14","doi-asserted-by":"crossref","first-page":"787","DOI":"10.2214\/ajr.150.4.787","article-title":"Migration of breast biopsy localisation wire","volume":"150","author":"Davis","year":"1988","journal-title":"AJR"},{"key":"2024092809401205500_bib15","doi-asserted-by":"crossref","first-page":"919","DOI":"10.2214\/ajr.151.5.919","article-title":"Localisation of nonpalpable breast lesions with the curved-end, retractable wire: leaving the needle in vivo","volume":"151","author":"Homer","year":"1988","journal-title":"AJR"},{"key":"2024092809401205500_bib16","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1148\/radiology.157.2.4048466","article-title":"Spring hookwire breast localiser: use with rigid-compression mammo-graphic systems","volume":"157","author":"Kopans","year":"1985","journal-title":"Radiology"},{"key":"2024092809401205500_bib17","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1016\/0002-9610(87)90256-X","article-title":"An improved system for surgical excision of needle-localised nonpalpable breast lesions","volume":"154","author":"Kwasnik","year":"1987","journal-title":"Am J Surg"},{"key":"2024092809401205500_bib18","first-page":"239","article-title":"Mammographic wire localisation in diagnosis and treatment of occult carcinoma of the breast","volume":"168","author":"Petrovich","year":"1989","journal-title":"Surg Gynecol Obstet"},{"key":"2024092809401205500_bib19","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1016\/0002-9610(89)90647-8","article-title":"Preoperative needle localisation to detect early breast cancer","volume":"157","author":"Rusnak","year":"1989","journal-title":"Am J Surg"},{"key":"2024092809401205500_bib20","doi-asserted-by":"crossref","first-page":"13-15B","DOI":"10.1016\/S0002-9610(88)80605-6","article-title":"Needle localization breast biopsy: accuracy versus cost","volume":"156","author":"Norton","year":"1988","journal-title":"Am J Surg"},{"key":"2024092809401205500_bib21","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1007\/978-3-642-82031-1_18","article-title":"Localization and significance of clinically occult breast lesions: experience with 469 needle-guided biopsies","volume":"90","author":"Schwartz","year":"1984","journal-title":"Recent Results Cancer Res"},{"key":"2024092809401205500_bib22","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1016\/0140-6736(90)90747-S","article-title":"Extent, distribution and mammo-graphic\/histological correlations of breast ductal carcinoma in situ","volume":"335","author":"Holland","year":"1990","journal-title":"Lancet"},{"key":"2024092809401205500_bib23","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1016\/0090-8258(89)90545-3","article-title":"Mammographic localization and biopsy: the experience of a gynecologic oncology group","volume":"33","author":"Stock","year":"1989","journal-title":"Gynecol Oncol"},{"key":"2024092809401205500_bib24","first-page":"1588","article-title":"Needle localisation of impalpable breast lesions","volume":"67","author":"Michell","year":"1989","journal-title":"Surgery (UK)"}],"container-title":["Journal of British Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fbjs.1800780926","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/academic.oup.com\/bjs\/article-pdf\/78\/9\/1113\/59394198\/bjs1800780926.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjs\/article-pdf\/78\/9\/1113\/59394198\/bjs1800780926.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,28]],"date-time":"2024-09-28T09:40:45Z","timestamp":1727516445000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjs\/article\/78\/9\/1113\/6175048"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1991,9,1]]},"references-count":24,"journal-issue":{"issue":"9","published-online":{"date-parts":[[1991,9,1]]},"published-print":{"date-parts":[[1991,9,1]]}},"URL":"https:\/\/doi.org\/10.1002\/bjs.1800780926","relation":{},"ISSN":["0007-1323","1365-2168"],"issn-type":[{"type":"print","value":"0007-1323"},{"type":"electronic","value":"1365-2168"}],"subject":[],"published-other":{"date-parts":[[1991,9]]},"published":{"date-parts":[[1991,9,1]]}}}