{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,26]],"date-time":"2025-10-26T22:47:22Z","timestamp":1761518842546},"reference-count":14,"publisher":"Oxford University Press (OUP)","issue":"7","license":[{"start":{"date-parts":[[1996,7,1]],"date-time":"1996-07-01T00:00:00Z","timestamp":836179200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[1996,7,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>A retrospective study was conducted into technetium-99m sestamibi imaging of primary hyperparathyroidism to determine the accuracy of identification and localization of parathyroid pathology. Of 56 patients studied, 48 had full preoperative scan data, operative data and pathological results analysed. Overall scan accuracy was 96 per cent. For single gland pathology (adenoma) imaging had a sensitivity of 97 per cent, a specificity of 100 per cent and a positive predictive value of 100 percent. For single gland disease the side was correctly identified in 100 per cent of cases and the site in 94 per cent, but the respective values were only 82 and 79 per cent for multiple gland pathology. Technetium-99m sestamibi imaging is highly sensitive and accurate for primary hyperparathyroidism, with sufficient positive predictive value and accuracy in single gland disease to allow scan-directed unilateral neck exploration.<\/jats:p>","DOI":"10.1002\/bjs.1800830734","type":"journal-article","created":{"date-parts":[[2007,3,3]],"date-time":"2007-03-03T03:07:58Z","timestamp":1172891278000},"page":"989-991","source":"Crossref","is-referenced-by-count":78,"title":["Technetium-99m sestamibi parathyroid localization is accurate enough for scan-directed unilateral neck exploration"],"prefix":"10.1093","volume":"83","author":[{"given":"N R","family":"Borley","sequence":"first","affiliation":[{"name":"Department of Surgery and Nuclear Medicine, Kent and Canterbury NHS Trust , Ethelbert Road, Canterbury CT1 3NG,","place":["UK"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R E C","family":"Collins","sequence":"additional","affiliation":[{"name":"Department of Surgery and Nuclear Medicine, Kent and Canterbury NHS Trust , Ethelbert Road, Canterbury CT1 3NG,","place":["UK"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M","family":"O'Doherty","sequence":"additional","affiliation":[{"name":"Department of Surgery and Nuclear Medicine, Kent and Canterbury NHS Trust , Ethelbert Road, Canterbury CT1 3NG,","place":["UK"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A","family":"Coakley","sequence":"additional","affiliation":[{"name":"Department of Surgery and Nuclear Medicine, Kent and Canterbury NHS Trust , Ethelbert Road, Canterbury CT1 3NG,","place":["UK"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[1996,7,1]]},"reference":[{"key":"2024092910052673600_bib1","first-page":"1313","article-title":"Parathyroid imaging with technetium-99m-sestamibi: preoperative localization and tissue uptake studies","volume":"33","author":"O'Doherty","year":"1992","journal-title":"J Nucl Med"},{"key":"2024092910052673600_bib2","first-page":"814","article-title":"The anatomy of primary hyperparathyroidism","volume":"92","author":"Thompson","year":"1982","journal-title":"Surgery"},{"key":"2024092910052673600_bib3","doi-asserted-by":"crossref","first-page":"593","DOI":"10.7326\/0003-4819-114-7-593","article-title":"Diagnosis and management of asymptomatic primary hyperparathyroidism: consensus development conference statement","volume":"114","author":"Consensus Development Conference Panel NIH Conference","year":"1991","journal-title":"Ann Intern Med"},{"key":"2024092910052673600_bib4","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/S0002-9610(05)80976-6","article-title":"Parathyroid localization prior to primary exploration","volume":"166","author":"Shaha","year":"1993","journal-title":"Am J Surg"},{"key":"2024092910052673600_bib5","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1007\/BF00998157","article-title":"Parathyroid imaging by Tc\/Ti scintigraphy","volume":"16","author":"Sandrock","year":"1990","journal-title":"Eur J Nud Med"},{"key":"2024092910052673600_bib6","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/S0002-9610(05)80332-0","article-title":"Parathyroid localization: inability to predict multiple gland involvement","volume":"166","author":"Heller","year":"1993","journal-title":"Am J Surg"},{"key":"2024092910052673600_bib7","first-page":"509","article-title":"Preoperative ultrasound and thallium-technetium subtraction scintigraphy in localizing parathyroid lesions in patients with hyperparathyroidism","volume":"59","author":"Thompson","year":"1993","journal-title":"Am Surg"},{"key":"2024092910052673600_bib8","first-page":"12","article-title":"Impact of technetium-99m-sestamibi localization on operative time and success of operations for primary hyperparathyroidism","volume":"60","author":"Casas","year":"1994","journal-title":"Am Surg"},{"key":"2024092910052673600_bib9","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1002\/bjs.1800780522","article-title":"Preoperative localization of parathyroid tumours does not reduce operating time","volume":"78","author":"Serpell","year":"1991","journal-title":"Br J Surg"},{"key":"2024092910052673600_bib10","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1097\/00006231-198911000-00003","article-title":"99mTc sestamibi\u2014a new agent for parathyroid imaging","volume":"10","author":"Coakley","year":"1989","journal-title":"Nucl Med Commun"},{"key":"2024092910052673600_bib11","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.2214\/ajr.161.6.8249740","article-title":"Parathyroid scintigraphy with iodine-123 and 99mTc-sestamibi: imaging findings","volume":"161","author":"Burke","year":"1993","journal-title":"AJR Am J Roentgenol"},{"key":"2024092910052673600_bib12","first-page":"1111","article-title":"Prospective evaluation of the efficacy of technetium 99m sestamibi and iodine 123 radionuclide imaging of abnormal parathyroid glands","volume":"112","author":"Wei","year":"1992","journal-title":"Surgery"},{"key":"2024092910052673600_bib13","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/S0002-9610(05)80335-6","article-title":"Prospective comparison of technetium-99m-sestamibi\/iodine-123 radionuclide scan versus high-resolution ultrasonography for the preoperative localization of abnormal parathyroid glands in patients with previously unoperated primary hyperparathyroidism","volume":"166","author":"Casas","year":"1993","journal-title":"Am J Surg"},{"key":"2024092910052673600_bib14","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1007\/BF01658540","article-title":"Scan-directed unilateral cervical exploration for parathyroid adenoma: a legitimate approach?","volume":"14","author":"Russell","year":"1990","journal-title":"World J Surg"}],"container-title":["Journal of British Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fbjs.1800830734","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fbjs.1800830734","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/academic.oup.com\/bjs\/article-pdf\/83\/7\/989\/59427860\/bjs1800830734.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjs\/article-pdf\/83\/7\/989\/59427860\/bjs1800830734.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,29]],"date-time":"2024-09-29T11:21:44Z","timestamp":1727608904000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjs\/article\/83\/7\/989\/6167749"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1996,7,1]]},"references-count":14,"journal-issue":{"issue":"7","published-online":{"date-parts":[[1996,7,1]]},"published-print":{"date-parts":[[1996,7,1]]}},"URL":"https:\/\/doi.org\/10.1002\/bjs.1800830734","relation":{},"ISSN":["0007-1323","1365-2168"],"issn-type":[{"type":"print","value":"0007-1323"},{"type":"electronic","value":"1365-2168"}],"subject":[],"published-other":{"date-parts":[[1996,7]]},"published":{"date-parts":[[1996,7,1]]}}}