{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,18]],"date-time":"2026-10-18T10:08:27Z","timestamp":1792318107446,"version":"4.4.0"},"reference-count":31,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2014,1,1]],"date-time":"2014-01-01T00:00:00Z","timestamp":1388534400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014,1,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>Background<\/jats:title>\n                  <jats:p>Totally implantable venous access devices (TIVADs) are commonly used in patients with cancer. Although several methods of implantation have been described, there is not enough evidence to support the use of a specific technique on a daily basis. The objective of this study was systematically to assess the literature comparing percutaneous subclavian vein puncture with surgical venous cutdown.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>MEDLINE, Embase and the Cochrane Central Register of Controlled Trials were searched by two independent authors. No time limits were applied. A systematic review and meta-analysis was carried out according to the recommendations of the Cochrane Collaboration, including randomized clinical trials comparing primary percutaneous subclavian vein puncture with surgical venous cutdown.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Six trials were included, with 772 patients overall. The primary implantation failure rate was significantly lower for the percutaneous approach compared with surgical cutdown (odds ratio (OR) 0\u00b726, 95 per cent confidence interval (c.i.) 0\u00b707 to 0\u00b794; P = 0\u00b7039). There was no evidence supporting a significant difference in terms of risk of pneumothorax, haematoma, venous thrombosis, infectious events or catheter migration. After taking between-study heterogeneity into account by using a random-effects model, procedure duration was not significantly longer for surgical cutdown: weighted mean difference +4 (95 per cent c.i. \u201312 to 20) min (P = 0\u00b7625).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusion<\/jats:title>\n                  <jats:p>Percutaneous subclavian vein puncture is associated with a higher TIVAD implantation success rate and a procedure duration similar to that of surgical cutdown. Pneumothorax develops exclusively after percutaneous puncture and requires special attention from clinicians dealing with TIVAD insertion.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1002\/bjs.9276","type":"journal-article","created":{"date-parts":[[2013,11,26]],"date-time":"2013-11-26T10:49:21Z","timestamp":1385462961000},"page":"8-16","source":"Crossref","is-referenced-by-count":39,"title":["Systematic review and meta-analysis of percutaneous subclavian vein puncture <i>versus<\/i> surgical venous cutdown for the insertion of a totally implantable venous access device"],"prefix":"10.1093","volume":"101","author":[{"given":"L A","family":"Orci","sequence":"first","affiliation":[{"name":"Division of Visceral Surgery, Department of Surgery, Geneva University Hospitals and Faculty of Medicine, University of Geneva , 4 Rue Gabrielle-Perret-Gentil, 1211 Geneva 4,","place":["Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R P H","family":"Meier","sequence":"additional","affiliation":[{"name":"Division of Visceral Surgery, Department of Surgery, Geneva University Hospitals and Faculty of Medicine, University of Geneva , 4 Rue Gabrielle-Perret-Gentil, 1211 Geneva 4,","place":["Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P","family":"Morel","sequence":"additional","affiliation":[{"name":"Division of Visceral Surgery, Department of Surgery, Geneva University Hospitals and Faculty of Medicine, University of Geneva , 4 Rue Gabrielle-Perret-Gentil, 1211 Geneva 4,","place":["Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W","family":"Staszewicz","sequence":"additional","affiliation":[{"name":"Division of Visceral Surgery, Department of Surgery, Geneva University Hospitals and Faculty of Medicine, University of Geneva , 4 Rue Gabrielle-Perret-Gentil, 1211 Geneva 4,","place":["Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C","family":"Toso","sequence":"additional","affiliation":[{"name":"Division of Visceral Surgery, Department of Surgery, Geneva University Hospitals and Faculty of Medicine, University of Geneva , 4 Rue Gabrielle-Perret-Gentil, 1211 Geneva 4,","place":["Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2014,1,1]]},"reference":[{"key":"2024092904540850900_bjs9276-bib-0001","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.clon.2007.04.003","article-title":"A comparison of Hickman line- and Port-a-Cath-associated complications in patients with solid tumours undergoing chemotherapy","volume":"19","author":"Ng","year":"2007","journal-title":"Clin Oncol (R Coll Radiol)"},{"key":"2024092904540850900_bjs9276-bib-0002","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.1245\/s10434-010-1005-4","article-title":"Increased use of percutaneous technique for totally implantable venous access devices. Is it real progress? A 27-year comprehensive review on early complications","volume":"17","author":"Di Carlo","year":"2010","journal-title":"Ann Surg Oncol"},{"key":"2024092904540850900_bjs9276-bib-0003","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.1053\/rmed.2000.0943","article-title":"Experience of totally implantable venous access devices (TIVADs) in adults with cystic fibrosis over a 13-year period","volume":"94","author":"Kariyawasam","year":"2000","journal-title":"Respir Med"},{"key":"2024092904540850900_bjs9276-bib-0004","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1001\/archsurg.136.9.1050","article-title":"Totally implantable venous access devices implanted surgically: a retrospective study on early and late complications","volume":"136","author":"Di Carlo","year":"2001","journal-title":"Arch Surg"},{"key":"2024092904540850900_bjs9276-bib-0005","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1245\/ASO.2005.04.028","article-title":"External jugular vein cutdown approach, as a useful alternative, supports the choice of the cephalic vein for totally implantable access device placement","volume":"12","author":"Di Carlo","year":"2005","journal-title":"Ann Surg Oncol"},{"key":"2024092904540850900_bjs9276-bib-0006","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1002\/(SICI)1096-9098(200003)73:3<172::AID-JSO11>3.0.CO;2-Z","article-title":"Catheter fracture and cardiac migration: a rare complication of totally implantable venous devices","volume":"73","author":"di Carlo","year":"2000","journal-title":"J Surg Oncol"},{"key":"2024092904540850900_bjs9276-bib-0007","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1007\/s10353-012-0157-9","article-title":"Subclavian vein puncture versus surgical cut-down to the cephalic vein for insertion of totally implantable venous access ports","volume":"44","author":"Dauser","year":"2012","journal-title":"Eur Surg"},{"key":"2024092904540850900_bjs9276-bib-0008","doi-asserted-by":"crossref","first-page":"264","DOI":"10.7326\/0003-4819-151-4-200908180-00135","article-title":"Altman DG; PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement","volume":"151","author":"Moher","year":"2009","journal-title":"Ann Intern Med"},{"key":"2024092904540850900_bjs9276-bib-0009","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0197-2456(95)00134-4","article-title":"Assessing the quality of reports of randomized clinical trials: is blinding necessary?","volume":"17","author":"Jadad","year":"1996","journal-title":"Control Clin Trials"},{"key":"2024092904540850900_bjs9276-bib-0010","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1002\/sim.1186","article-title":"Quantifying heterogeneity in a meta-analysis","volume":"21","author":"Higgins","year":"2002","journal-title":"Stat Med"},{"key":"2024092904540850900_bjs9276-bib-0011","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/0197-2456(86)90046-2","article-title":"Meta-analysis in clinical trials","volume":"7","author":"DerSimonian","year":"1986","journal-title":"Control Clin Trials"},{"key":"2024092904540850900_bjs9276-bib-0012","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1002\/bjs.6457","article-title":"Randomized clinical trial of a modified Seldinger technique for open central venous cannulation for implantable access devices","volume":"96","author":"Knebel","year":"2009","journal-title":"Br J Surg"},{"key":"2024092904540850900_bjs9276-bib-0013","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1093\/annonc\/mdn701","article-title":"Best choice of central venous insertion site for the prevention of catheter-related complications in adult patients who need cancer therapy: a randomized trial","volume":"20","author":"Biffi","year":"2009","journal-title":"Ann Oncol"},{"key":"2024092904540850900_bjs9276-bib-0014","first-page":"52","article-title":"Subcutaneous venous indwelling: cutdown versus percutaneous puncture insertion","volume":"26","author":"Boldo","year":"2003","journal-title":"Oncologia"},{"key":"2024092904540850900_bjs9276-bib-0015","first-page":"495","article-title":"Prospective randomised study of cephalic vein cut-down versus subclavian vein puncture technique in the implantation of subcutaneous venous access devices","volume":"54","author":"D'Angelo","year":"2002","journal-title":"Chir Ital"},{"key":"2024092904540850900_bjs9276-bib-0016","doi-asserted-by":"crossref","first-page":"1111","DOI":"10.1097\/SLA.0b013e318214ba21","article-title":"Insertion of totally implantable venous access devices: an expertise-based, randomized, controlled trial (NCT00600444)","volume":"253","author":"Knebel","year":"2011","journal-title":"Ann Surg"},{"key":"2024092904540850900_bjs9276-bib-0017","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1002\/bjs.6730","article-title":"Randomized clinical trial comparing venous cutdown with the Seldinger technique for placement of implantable venous access ports","volume":"96","author":"Nocito","year":"2009","journal-title":"Br J Surg"},{"key":"2024092904540850900_bjs9276-bib-0018","first-page":"305","article-title":"Totally implantable venous access ports: a clinical trial comparing percutaneous versus surgical technique","volume":"58","author":"Riapisarda","year":"2006","journal-title":"Chir Ital"},{"key":"2024092904540850900_bjs9276-bib-0019","first-page":"706","article-title":"Totally implanted venous and arterial access system to replace external catheters in cancer treatment","volume":"92","author":"Niederhuber","year":"1982","journal-title":"Surgery"},{"key":"2024092904540850900_bjs9276-bib-0020","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1023\/A:1008392423469","article-title":"Totally implantable central venous access ports for long-term chemotherapy. A prospective study analyzing complications and costs of 333 devices with a minimum follow-up of 180 days","volume":"9","author":"Biffi","year":"1998","journal-title":"Ann Oncol"},{"key":"2024092904540850900_bjs9276-bib-0021","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1002\/jso.20584","article-title":"Guidewire assisted cephalic vein cutdown for insertion of totally implantable access ports","volume":"95","author":"Chang","year":"2007","journal-title":"J Surg Oncol"},{"key":"2024092904540850900_bjs9276-bib-0022","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1002\/jso.20410","article-title":"Surgical technique for totally implantable access ports (TIAP) needs improvement: a multivariate analysis of 400 patients","volume":"93","author":"Seiler","year":"2006","journal-title":"J Surg Oncol"},{"key":"2024092904540850900_bjs9276-bib-0023","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1002\/jso.21990","article-title":"Totally implantable central venous access ports. Analysis of 700 cases","volume":"104","author":"Barbetakis","year":"2011","journal-title":"J Surg Oncol"},{"key":"2024092904540850900_bjs9276-bib-0024","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1159\/000011947","article-title":"Complications of subcutaneous infusion port in the general oncology population","volume":"56","author":"Ballarini","year":"1999","journal-title":"Oncology"},{"key":"2024092904540850900_bjs9276-bib-0025","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1177\/000313489906500605","article-title":"\u2018Blind\u2019 placement of long-term central venous access devices: report of 589 consecutive procedures","volume":"65","author":"Kincaid","year":"1999","journal-title":"Am Surg"},{"key":"2024092904540850900_bjs9276-bib-0026","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1136\/bmj.327.7411.361","article-title":"Ultrasonic locating devices for central venous cannulation: meta-analysis","volume":"327","author":"Hind","year":"2003","journal-title":"BMJ"},{"key":"2024092904540850900_bjs9276-bib-0027","doi-asserted-by":"crossref","first-page":"2053","DOI":"10.1097\/00003246-199612000-00020","article-title":"Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature","volume":"24","author":"Randolph","year":"1996","journal-title":"Crit Care Med"},{"key":"2024092904540850900_bjs9276-bib-0028","author":"National Institute for Health and Clinical Excellence (NICE)","year":"2002","journal-title":"Guidance on the Use of Ultrasound Locating Devices for Placing Central Venous Catheters"},{"key":"2024092904540850900_bjs9276-bib-0029","doi-asserted-by":"crossref","first-page":"2101","DOI":"10.1001\/archinte.160.14.2101","article-title":"Depression is a risk factor for noncompliance with medical treatment: meta-analysis of the effects of anxiety and depression on patient adherence","volume":"160","author":"DiMatteo","year":"2000","journal-title":"Arch Intern Med"},{"key":"2024092904540850900_bjs9276-bib-0030","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1097\/01.mlr.0000127998.89246.ef","article-title":"Chronic medical illness, depression, and use of acute medical services among Medicare beneficiaries","volume":"42","author":"Himelhoch","year":"2004","journal-title":"Med Care"},{"key":"2024092904540850900_bjs9276-bib-0031","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1093\/aje\/kwj069","article-title":"Bias in clinical intervention research","volume":"163","author":"Gluud","year":"2006","journal-title":"Am J Epidemiol"}],"container-title":["Journal of British Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fbjs.9276","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/academic.oup.com\/bjs\/article-pdf\/101\/2\/8\/59424656\/bjs9276.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjs\/article-pdf\/101\/2\/8\/59424656\/bjs9276.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,29]],"date-time":"2024-09-29T04:54:21Z","timestamp":1727585661000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjs\/article\/101\/2\/8\/6054646"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,1,1]]},"references-count":31,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2014,1,1]]},"published-print":{"date-parts":[[2014,1,1]]}},"URL":"https:\/\/doi.org\/10.1002\/bjs.9276","relation":{},"ISSN":["0007-1323","1365-2168"],"issn-type":[{"value":"0007-1323","type":"print"},{"value":"1365-2168","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2014,1]]},"published":{"date-parts":[[2014,1,1]]}}}